Message ID | 1419265668-32283-4-git-send-email-l.majewski@samsung.com (mailing list archive) |
---|---|
State | New, archived |
Headers | show |
On Mon, Dec 22, 2014 at 05:27:43PM +0100, Lukasz Majewski wrote: > Several new properties to allow PWM fan working as a cooling device have been > combined into this single commit. > Patch prefix should look something like 'dt-bindings: ...', or better 'Documentation: devicetree: ...', or 'Documentation: bindings: ...' > Signed-off-by: Lukasz Majewski <l.majewski@samsung.com> > --- > Changes for v2: > - Rename cooling-pwm-values to cooling-levels > - Remove default-pulse-width property and stick to default hwmon policy > --- > .../devicetree/bindings/hwmon/pwm-fan.txt | 23 ++++++++++++++++++++++ > 1 file changed, 23 insertions(+) > > diff --git a/Documentation/devicetree/bindings/hwmon/pwm-fan.txt b/Documentation/devicetree/bindings/hwmon/pwm-fan.txt > index 610757c..001446a 100644 > --- a/Documentation/devicetree/bindings/hwmon/pwm-fan.txt > +++ b/Documentation/devicetree/bindings/hwmon/pwm-fan.txt > @@ -3,10 +3,33 @@ Bindings for a fan connected to the PWM lines > Required properties: > - compatible : "pwm-fan" > - pwms : the PWM that is used to control the PWM fan > +- cooling-levels : PWM duty cycle values in a range from 0 to 255 > + which correspond to thermal cooling states > + > +Thorough description of the following bindings: > + cooling-min-state = <0>; > + cooling-max-state = <3>; > + #cooling-cells = <2>; > + thermal-zone { > + cpu_thermal: cpu-thermal { > + cooling-maps { > + map0 { > + trip = <&cpu_alert1>; > + cooling-device = <&fan0 0 1>; > + }; > + }; > + }; > + > +for PWM FAN used as cooling device can be found at: > +./Documentation/devicetree/bindings/thermal/thermal.txt > > Example: > pwm-fan { > compatible = "pwm-fan"; > status = "okay"; > pwms = <&pwm 0 10000 0>; > + cooling-min-state = <0>; > + cooling-max-state = <3>; > + #cooling-cells = <2>; > + cooling-levels = <0 102 170 255>; > }; > -- > 2.0.0.rc2 >
diff --git a/Documentation/devicetree/bindings/hwmon/pwm-fan.txt b/Documentation/devicetree/bindings/hwmon/pwm-fan.txt index 610757c..001446a 100644 --- a/Documentation/devicetree/bindings/hwmon/pwm-fan.txt +++ b/Documentation/devicetree/bindings/hwmon/pwm-fan.txt @@ -3,10 +3,33 @@ Bindings for a fan connected to the PWM lines Required properties: - compatible : "pwm-fan" - pwms : the PWM that is used to control the PWM fan +- cooling-levels : PWM duty cycle values in a range from 0 to 255 + which correspond to thermal cooling states + +Thorough description of the following bindings: + cooling-min-state = <0>; + cooling-max-state = <3>; + #cooling-cells = <2>; + thermal-zone { + cpu_thermal: cpu-thermal { + cooling-maps { + map0 { + trip = <&cpu_alert1>; + cooling-device = <&fan0 0 1>; + }; + }; + }; + +for PWM FAN used as cooling device can be found at: +./Documentation/devicetree/bindings/thermal/thermal.txt Example: pwm-fan { compatible = "pwm-fan"; status = "okay"; pwms = <&pwm 0 10000 0>; + cooling-min-state = <0>; + cooling-max-state = <3>; + #cooling-cells = <2>; + cooling-levels = <0 102 170 255>; };
Several new properties to allow PWM fan working as a cooling device have been combined into this single commit. Signed-off-by: Lukasz Majewski <l.majewski@samsung.com> --- Changes for v2: - Rename cooling-pwm-values to cooling-levels - Remove default-pulse-width property and stick to default hwmon policy --- .../devicetree/bindings/hwmon/pwm-fan.txt | 23 ++++++++++++++++++++++ 1 file changed, 23 insertions(+)