Message ID | 1452586185-818-3-git-send-email-wenyou.yang@atmel.com (mailing list archive) |
---|---|
State | Not Applicable, archived |
Headers | show |
On 12.01.2016 17:09, Wenyou Yang wrote: > This patch adds documentation for the DT bindings of the charger > subdevice of ACT8945A MFD. > > Signed-off-by: Wenyou Yang <wenyou.yang@atmel.com> > --- > > Changes in v3: None > Changes in v2: None > > .../devicetree/bindings/power/act8945a-charger.txt | 34 ++++++++++++++++++++ > 1 file changed, 34 insertions(+) > create mode 100644 Documentation/devicetree/bindings/power/act8945a-charger.txt > > diff --git a/Documentation/devicetree/bindings/power/act8945a-charger.txt b/Documentation/devicetree/bindings/power/act8945a-charger.txt > new file mode 100644 > index 0000000..868e0164 > --- /dev/null > +++ b/Documentation/devicetree/bindings/power/act8945a-charger.txt > @@ -0,0 +1,34 @@ > +Device-Tree bindings for charger of Active-semi ACT8945A Multi-Function Device > + > +Required properties: > + - compatible: "active-semi,act8945a-charger" > + - active-semi,chglev-gpio = Specifies a gpio that uses to select > + the charge current level. active-semi,chglev-gpios See: Documentation/devicetree/bindings/gpio/gpio.txt > + > +Optional properties: > + - active-semi,battery_temperature: Indicates if it is allowed to check > + the battery temperature. If it is missing, assume the battery temperature > + is not allowed to check. Here and in rest of properties - no underscores but hyphens. The name suggests that this is a value... but this is a boolean? > + - active-semi,input_voltage_threshold: unit: mV; > + Specifies the charger's input over-voltage threshold value; > + The value can be: 6600, 7000, 7500, 8000; default: 6600 I think adding units suffix in binding is preferred. so "-microvolt"? Best regards, Krzysztof > + - active-semi,precondition_timeout: unit: minutes; > + Specifies the charger's PRECONDITION safety timer setting value; > + The value can be: 40, 60, 80, 0; If 0, it means to disable this timer; > + default: 40. > + - active-semi,total_timeout: unit: hours; > + Specifies the charger's total safety timer setting value; > + The value can be: 3, 4, 5, 0; If 0, it means to disable this timer; > + default: 3. > + > +Example: > + > + charger { > + compatible = "active-semi,act8945a-charger"; > + pinctrl-names = "default"; > + pinctrl-0 = <&pinctrl_charger_chglev>; > + active-semi,chglev-gpio = <&pioA 12 GPIO_ACTIVE_HIGH>; > + active-semi,input_voltage_threshold = <6600>; > + active-semi,precondition_timeout = <40>; > + active-semi,total_timeout = <3>; > + }; > -- To unsubscribe from this list: send the line "unsubscribe linux-pm" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
Hi Krzysztof, Thank you for your so much feedback. I will change it in next version. > -----Original Message----- > From: Krzysztof Kozlowski [mailto:k.kozlowski@samsung.com] > Sent: 2016?1?13? 10:00 > To: Yang, Wenyou <Wenyou.Yang@atmel.com>; Sebastian Reichel > <sre@kernel.org>; Dmitry Eremin-Solenikov <dbaryshkov@gmail.com>; David > Woodhouse <dwmw2@infradead.org>; Rob Herring <robh+dt@kernel.org>; Pawel > Moll <pawel.moll@arm.com>; Mark Rutland <mark.rutland@arm.com>; Ian > Campbell <ijc+devicetree@hellion.org.uk>; Kumar Gala <galak@codeaurora.org> > Cc: Javier Martinez Canillas <javier@dowhile0.org>; Lee Jones > <lee.jones@linaro.org>; Ferre, Nicolas <Nicolas.FERRE@atmel.com>; linux-arm- > kernel@lists.infradead.org; linux-kernel@vger.kernel.org; linux- > pm@vger.kernel.org > Subject: Re: [PATCH v3 2/2] power: add documentation for ACT8945A's charger > DT bindings > > On 12.01.2016 17:09, Wenyou Yang wrote: > > This patch adds documentation for the DT bindings of the charger > > subdevice of ACT8945A MFD. > > > > Signed-off-by: Wenyou Yang <wenyou.yang@atmel.com> > > --- > > > > Changes in v3: None > > Changes in v2: None > > > > .../devicetree/bindings/power/act8945a-charger.txt | 34 > ++++++++++++++++++++ > > 1 file changed, 34 insertions(+) > > create mode 100644 > > Documentation/devicetree/bindings/power/act8945a-charger.txt > > > > diff --git > > a/Documentation/devicetree/bindings/power/act8945a-charger.txt > > b/Documentation/devicetree/bindings/power/act8945a-charger.txt > > new file mode 100644 > > index 0000000..868e0164 > > --- /dev/null > > +++ b/Documentation/devicetree/bindings/power/act8945a-charger.txt > > @@ -0,0 +1,34 @@ > > +Device-Tree bindings for charger of Active-semi ACT8945A > > +Multi-Function Device > > + > > +Required properties: > > + - compatible: "active-semi,act8945a-charger" > > + - active-semi,chglev-gpio = Specifies a gpio that uses to select > > + the charge current level. > > active-semi,chglev-gpios > See: Documentation/devicetree/bindings/gpio/gpio.txt > > > + > > +Optional properties: > > + - active-semi,battery_temperature: Indicates if it is allowed to check > > + the battery temperature. If it is missing, assume the battery temperature > > + is not allowed to check. > > Here and in rest of properties - no underscores but hyphens. The name suggests > that this is a value... but this is a boolean? > > > + - active-semi,input_voltage_threshold: unit: mV; > > + Specifies the charger's input over-voltage threshold value; > > + The value can be: 6600, 7000, 7500, 8000; default: 6600 > > I think adding units suffix in binding is preferred. so "-microvolt"? > > Best regards, > Krzysztof > > > > + - active-semi,precondition_timeout: unit: minutes; > > + Specifies the charger's PRECONDITION safety timer setting value; > > + The value can be: 40, 60, 80, 0; If 0, it means to disable this timer; > > + default: 40. > > + - active-semi,total_timeout: unit: hours; > > + Specifies the charger's total safety timer setting value; > > + The value can be: 3, 4, 5, 0; If 0, it means to disable this timer; > > + default: 3. > > + > > +Example: > > + > > + charger { > > + compatible = "active-semi,act8945a-charger"; > > + pinctrl-names = "default"; > > + pinctrl-0 = <&pinctrl_charger_chglev>; > > + active-semi,chglev-gpio = <&pioA 12 GPIO_ACTIVE_HIGH>; > > + active-semi,input_voltage_threshold = <6600>; > > + active-semi,precondition_timeout = <40>; > > + active-semi,total_timeout = <3>; > > + }; > > Best Regards, Wenyou Yang
diff --git a/Documentation/devicetree/bindings/power/act8945a-charger.txt b/Documentation/devicetree/bindings/power/act8945a-charger.txt new file mode 100644 index 0000000..868e0164 --- /dev/null +++ b/Documentation/devicetree/bindings/power/act8945a-charger.txt @@ -0,0 +1,34 @@ +Device-Tree bindings for charger of Active-semi ACT8945A Multi-Function Device + +Required properties: + - compatible: "active-semi,act8945a-charger" + - active-semi,chglev-gpio = Specifies a gpio that uses to select + the charge current level. + +Optional properties: + - active-semi,battery_temperature: Indicates if it is allowed to check + the battery temperature. If it is missing, assume the battery temperature + is not allowed to check. + - active-semi,input_voltage_threshold: unit: mV; + Specifies the charger's input over-voltage threshold value; + The value can be: 6600, 7000, 7500, 8000; default: 6600 + - active-semi,precondition_timeout: unit: minutes; + Specifies the charger's PRECONDITION safety timer setting value; + The value can be: 40, 60, 80, 0; If 0, it means to disable this timer; + default: 40. + - active-semi,total_timeout: unit: hours; + Specifies the charger's total safety timer setting value; + The value can be: 3, 4, 5, 0; If 0, it means to disable this timer; + default: 3. + +Example: + + charger { + compatible = "active-semi,act8945a-charger"; + pinctrl-names = "default"; + pinctrl-0 = <&pinctrl_charger_chglev>; + active-semi,chglev-gpio = <&pioA 12 GPIO_ACTIVE_HIGH>; + active-semi,input_voltage_threshold = <6600>; + active-semi,precondition_timeout = <40>; + active-semi,total_timeout = <3>; + };
This patch adds documentation for the DT bindings of the charger subdevice of ACT8945A MFD. Signed-off-by: Wenyou Yang <wenyou.yang@atmel.com> --- Changes in v3: None Changes in v2: None .../devicetree/bindings/power/act8945a-charger.txt | 34 ++++++++++++++++++++ 1 file changed, 34 insertions(+) create mode 100644 Documentation/devicetree/bindings/power/act8945a-charger.txt