On Sat, 24 Nov 2018 23:14:14 +0100 Tomasz Duszynski <tduszyns@gmail.com> wrote: > Add support for Sensirion SPS30 particulate matter sensor. > > Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> A few things inline. I'm particularly curious as to why we are ignoring two of the particle sizes that the sensor seems to capture? Also, a 'potential' race in remove that I'd like us to make 'obviously' correct rather than requiring hard thought on whether it would be a problem. Thanks, Jonathan > --- > drivers/iio/chemical/Kconfig | 11 ++ > drivers/iio/chemical/Makefile | 1 + > drivers/iio/chemical/sps30.c | 359 ++++++++++++++++++++++++++++++++++ > 3 files changed, 371 insertions(+) > create mode 100644 drivers/iio/chemical/sps30.c > > diff --git a/drivers/iio/chemical/Kconfig b/drivers/iio/chemical/Kconfig > index b8e005be4f87..40057ecf8130 100644 > --- a/drivers/iio/chemical/Kconfig > +++ b/drivers/iio/chemical/Kconfig > @@ -61,6 +61,17 @@ config IAQCORE > iAQ-Core Continuous/Pulsed VOC (Volatile Organic Compounds) > sensors > > +config SPS30 > + tristate "SPS30 Particulate Matter sensor" > + depends on I2C > + select CRC8 > + help > + Say Y here to build support for the Sensirion SPS30 Particulate > + Matter sensor. > + > + To compile this driver as a module, choose M here: the module will > + be called sps30. > + > config VZ89X > tristate "SGX Sensortech MiCS VZ89X VOC sensor" > depends on I2C > diff --git a/drivers/iio/chemical/Makefile b/drivers/iio/chemical/Makefile > index 2f4c4ba4d781..9f42f4252151 100644 > --- a/drivers/iio/chemical/Makefile > +++ b/drivers/iio/chemical/Makefile > @@ -9,4 +9,5 @@ obj-$(CONFIG_BME680_I2C) += bme680_i2c.o > obj-$(CONFIG_BME680_SPI) += bme680_spi.o > obj-$(CONFIG_CCS811) += ccs811.o > obj-$(CONFIG_IAQCORE) += ams-iaq-core.o > +obj-$(CONFIG_SPS30) += sps30.o > obj-$(CONFIG_VZ89X) += vz89x.o > diff --git a/drivers/iio/chemical/sps30.c b/drivers/iio/chemical/sps30.c > new file mode 100644 > index 000000000000..bf802621ae7f > --- /dev/null > +++ b/drivers/iio/chemical/sps30.c > @@ -0,0 +1,359 @@ > +// SPDX-License-Identifier: GPL-2.0 > +/* > + * Sensirion SPS30 Particulate Matter sensor driver > + * > + * Copyright (c) Tomasz Duszynski <tduszyns@gmail.com> > + * > + * I2C slave address: 0x69 > + * > + * TODO: > + * - support for turning on fan cleaning > + * - support for reading/setting auto cleaning interval > + */ > + > +#define pr_fmt(fmt) "sps30: " fmt > + > +#include <linux/crc8.h> > +#include <linux/delay.h> > +#include <linux/i2c.h> > +#include <linux/iio/buffer.h> > +#include <linux/iio/iio.h> > +#include <linux/iio/sysfs.h> > +#include <linux/iio/trigger_consumer.h> > +#include <linux/iio/triggered_buffer.h> > +#include <linux/module.h> > + > +#define SPS30_CRC8_POLYNOMIAL 0x31 > + > +/* SPS30 commands */ > +#define SPS30_START_MEAS 0x0010 > +#define SPS30_STOP_MEAS 0x0104 > +#define SPS30_RESET 0xd304 > +#define SPS30_READ_DATA_READY_FLAG 0x0202 > +#define SPS30_READ_DATA 0x0300 > +#define SPS30_READ_SERIAL 0xD033 > + > +#define SPS30_CHAN(_index, _mod) { \ > + .type = IIO_MASSCONCENTRATION, \ > + .modified = 1, \ > + .channel2 = IIO_MOD_ ## _mod, \ > + .info_mask_separate = BIT(IIO_CHAN_INFO_PROCESSED), \ > + .scan_index = _index, \ > + .scan_type = { \ > + .sign = 'u', \ > + .realbits = 12, \ > + .storagebits = 32, \ That is unusual. Why do we need 32 bits to store a 12 bit value? 16 should be plenty. It'll make a difference to the buffer sizes if people just want to stream data and don't care about timestamps as it'll halve the memory usage. Also, convention has always been to got for next 8,16,32,64 above the realbits if there isn't a reason not to (shifting etc) How did we end up with 12 bits off the floating point conversion anyway? Needs some docs. > + .endianness = IIO_CPU, \ > + }, \ > +} > + > +enum { > + PM1p0, /* just a placeholder */ > + PM2p5, > + PM4p0, /* just a placeholder */ > + PM10, > +}; > + > +struct sps30_state { > + struct i2c_client *client; > + /* guards against concurrent access to sensor registers */ > + struct mutex lock; > +}; > + > +DECLARE_CRC8_TABLE(sps30_crc8_table); > + I think you are fine locking wise, but it would be good to add a note on what locks are expected to be held on entering this function. Without locks it's obviously very racey! > +static int sps30_write_then_read(struct sps30_state *state, u8 *buf, > + int buf_size, u8 *data, int data_size) > +{ > + /* every two received data bytes are checksummed */ > + u8 tmp[data_size + data_size / 2]; > + int ret, i; > + > + /* > + * Sensor does not support repeated start so instead of > + * sending two i2c messages in a row we just send one by one. > + */ > + ret = i2c_master_send(state->client, buf, buf_size); > + if (ret != buf_size) > + return ret < 0 ? ret : -EIO; > + > + if (!data) > + return 0; > + > + ret = i2c_master_recv(state->client, tmp, sizeof(tmp)); > + if (ret != sizeof(tmp)) > + return ret < 0 ? ret : -EIO; > + > + for (i = 0; i < sizeof(tmp); i += 3) { > + u8 crc = crc8(sps30_crc8_table, &tmp[i], 2, CRC8_INIT_VALUE); > + > + if (crc != tmp[i + 2]) { > + dev_err(&state->client->dev, > + "data integrity check failed\n"); > + return -EIO; > + } > + > + *data++ = tmp[i]; > + *data++ = tmp[i + 1]; > + } > + > + return 0; > +} > + > +static int sps30_do_cmd(struct sps30_state *state, u16 cmd, u8 *data, int size) > +{ > + /* depending on the command up to 3 bytes may be needed for argument */ > + u8 buf[sizeof(cmd) + 3] = { cmd >> 8, cmd }; > + > + switch (cmd) { > + case SPS30_START_MEAS: > + buf[2] = 0x03; > + buf[3] = 0x00; > + buf[4] = 0xac; /* precomputed crc */ Could you put that in code and let the compiler do the pre compute? Might be a little more elegant. > + return sps30_write_then_read(state, buf, 5, NULL, 0); > + case SPS30_STOP_MEAS: > + case SPS30_RESET: > + return sps30_write_then_read(state, buf, 2, NULL, 0); > + case SPS30_READ_DATA_READY_FLAG: > + case SPS30_READ_DATA: > + case SPS30_READ_SERIAL: > + return sps30_write_then_read(state, buf, 2, data, size); > + default: > + return -EINVAL; > + }; > +} > + > +static int sps30_ieee754_to_int(const u8 *data) > +{ > + u32 val = ((u32)data[0] << 24) | ((u32)data[1] << 16) | > + ((u32)data[2] << 8) | (u32)data[3], Have a separate u32 mantissa = (val << 9) >> 9 line. What is this next line actually doing? Kind of looks like a mask? If so just mask it with & as more readable. > + mantissa = (val << 9) >> 9; > + int exp = (val >> 23) - 127; > + > + if (!exp && !mantissa) > + return 0; > + > + if (exp < 0) > + return 0; > + > + return (1 << exp) + (mantissa >> (23 - exp)); > +} > + > +static int sps30_do_meas(struct sps30_state *state, int *pm2p5, int *pm10) > +{ > + /* > + * Internally sensor stores measurements in a following manner: > + * > + * PM1p0: upper two bytes, crc8, lower two bytes, crc8 So there are other particle sizes that this sensor reads? Why are we mapping them down to just the two channel types? > + * PM2p5: upper two bytes, crc8, lower two bytes, crc8 > + * PM4p0: upper two bytes, crc8, lower two bytes, crc8 > + * PM10: upper two bytes, crc8, lower two bytes, crc8 > + * > + * What follows next are number concentration measurements and > + * typical particle size measurement. > + * > + * Once data is read from sensor crc bytes are stripped off > + * hence we need 16 bytes of buffer space. > + */ > + int ret, tries = 5; > + u8 buf[16]; > + > + while (tries--) { > + ret = sps30_do_cmd(state, SPS30_READ_DATA_READY_FLAG, buf, 2); > + if (ret) > + return -EIO; > + > + /* new measurements ready to be read */ > + if (buf[1] == 1) > + break; > + > + usleep_range(300000, 400000); > + } > + > + if (!tries) > + return -ETIMEDOUT; > + > + ret = sps30_do_cmd(state, SPS30_READ_DATA, buf, sizeof(buf)); > + if (ret) > + return ret; > + > + /* > + * All measurements come in IEEE754 single precision floating point > + * format but sensor itself is not precise enough (-+ 10% error) > + * to take full advantage of it. Hence converting result to int > + * to keep things simple. Interesting. We have talked about allowing floating point formats for sensors the provide them. Would that be beneficial here? > + */ > + *pm2p5 = sps30_ieee754_to_int(&buf[PM2p5 * 4]); > + *pm10 = sps30_ieee754_to_int(&buf[PM10 * 4]); > + > + return 0; > +} > + > +static irqreturn_t sps30_trigger_handler(int irq, void *p) > +{ > + struct iio_poll_func *pf = p; > + struct iio_dev *indio_dev = pf->indio_dev; > + struct sps30_state *state = iio_priv(indio_dev); > + u32 buf[4]; /* PM2p5, PM10, timestamp */ > + int ret; > + > + mutex_lock(&state->lock); > + ret = sps30_do_meas(state, &buf[0], &buf[1]); > + mutex_unlock(&state->lock); > + if (ret < 0) > + goto err; > + > + iio_push_to_buffers_with_timestamp(indio_dev, buf, > + iio_get_time_ns(indio_dev)); > +err: > + iio_trigger_notify_done(indio_dev->trig); > + > + return IRQ_HANDLED; > +} > + > +static int sps30_read_raw(struct iio_dev *indio_dev, > + struct iio_chan_spec const *chan, > + int *val, int *val2, long mask) > +{ > + struct sps30_state *state = iio_priv(indio_dev); > + int ret; > + > + switch (mask) { > + case IIO_CHAN_INFO_PROCESSED: > + switch (chan->type) { > + case IIO_MASSCONCENTRATION: > + mutex_lock(&state->lock); > + switch (chan->channel2) { > + case IIO_MOD_PM2p5: > + ret = sps30_do_meas(state, val, val2); > + break; > + case IIO_MOD_PM10: > + ret = sps30_do_meas(state, val2, val); > + break; > + default: > + break; > + } > + mutex_unlock(&state->lock); > + if (ret) > + return ret; > + > + return IIO_VAL_INT; > + default: > + return -EINVAL; > + } > + break; > + default: You can't get here. Is this a warning suppression? If so just add a comment saying so to prevent it being removed by someone else later. > + return -EINVAL; > + } > +} > + > +static const struct iio_info sps30_info = { > + .read_raw = sps30_read_raw, > +}; > + From a readability point of view, it would be helpful to pull the macro SPS30_CHAN down here in the code so we don't need to go jumping around to check what it is doing. > +static const struct iio_chan_spec sps30_channels[] = { > + SPS30_CHAN(0, PM2p5), > + SPS30_CHAN(1, PM10), > + IIO_CHAN_SOFT_TIMESTAMP(2), > +}; > + > +static const unsigned long sps30_scan_masks[] = { 0x03, 0x00 }; > + > +static int sps30_probe(struct i2c_client *client) > +{ > + struct iio_dev *indio_dev; > + struct sps30_state *state; > + u8 buf[32] = { }; > + int ret; > + > + if (!i2c_check_functionality(client->adapter, I2C_FUNC_I2C)) > + return -EOPNOTSUPP; > + > + indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*state)); > + if (!indio_dev) > + return -ENOMEM; > + > + state = iio_priv(indio_dev); > + i2c_set_clientdata(client, indio_dev); > + state->client = client; > + indio_dev->dev.parent = &client->dev; > + indio_dev->info = &sps30_info; > + indio_dev->name = client->name; > + indio_dev->channels = sps30_channels; > + indio_dev->num_channels = ARRAY_SIZE(sps30_channels); > + indio_dev->modes = INDIO_DIRECT_MODE; > + indio_dev->available_scan_masks = sps30_scan_masks; > + > + mutex_init(&state->lock); > + crc8_populate_msb(sps30_crc8_table, SPS30_CRC8_POLYNOMIAL); > + > + /* > + * Power-on-reset causes sensor to produce some glitch on i2c bus > + * and some controllers end up in error state. Recover simply > + * by placing something on the bus. > + */ > + ret = sps30_do_cmd(state, SPS30_RESET, NULL, 0); > + if (ret) { > + dev_err(&client->dev, "failed to reset device\n"); > + return ret; > + } > + usleep_range(2500000, 3500000); > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); Talk me through this logic. We stop it then pretty much immediately start it again? Needs a comment. > + > + ret = sps30_do_cmd(state, SPS30_READ_SERIAL, buf, sizeof(buf)); > + if (ret) { > + dev_err(&client->dev, "failed to read serial number\n"); > + return ret; > + } > + dev_info(&client->dev, "serial number: %s\n", buf); > + > + ret = sps30_do_cmd(state, SPS30_START_MEAS, NULL, 0); > + if (ret) { This is not unwound on error. See comment on remove race below. > + dev_err(&client->dev, "failed to start measurement\n"); > + return ret; > + } > + > + ret = devm_iio_triggered_buffer_setup(&client->dev, indio_dev, NULL, > + sps30_trigger_handler, NULL); > + if (ret) > + return ret; > + > + return devm_iio_device_register(&client->dev, indio_dev); > +} > + > +static int sps30_remove(struct i2c_client *client) > +{ > + struct iio_dev *indio_dev = i2c_get_clientdata(client); > + struct sps30_state *state = iio_priv(indio_dev); > + > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); This looks like a race to me. You turn off the measurements before removing the interface to them. It's certainly not in the 'obviously' right category. As such I would either use a devm action to do this stop, or not use the managed interfaces for everything in probe after the equivalent start. The devm_add_action_or_reset would be the cleanest option I think.. Will also fix the cleanup on error in probe. > + > + return 0; > +} > + > +static const struct i2c_device_id sps30_id[] = { > + { "sps30" }, > + { } > +}; > +MODULE_DEVICE_TABLE(i2c, sps30_id); > + > +static const struct of_device_id sps30_of_match[] = { > + { .compatible = "sensirion,sps30" }, > + { } > +}; > +MODULE_DEVICE_TABLE(of, sps30_of_match); > + > +static struct i2c_driver sps30_driver = { > + .driver = { > + .name = "sps30", > + .of_match_table = sps30_of_match, > + }, > + .id_table = sps30_id, > + .probe_new = sps30_probe, > + .remove = sps30_remove, > +}; > +module_i2c_driver(sps30_driver); > + > +MODULE_AUTHOR("Tomasz Duszynski <tduszyns@gmail.com>"); > +MODULE_DESCRIPTION("Sensirion SPS30 particulate matter sensor driver"); > +MODULE_LICENSE("GPL v2");
On Sat, Nov 24, 2018 at 11:14:14PM +0100, Tomasz Duszynski wrote: > Add support for Sensirion SPS30 particulate matter sensor. > > Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> > --- > drivers/iio/chemical/Kconfig | 11 ++ > drivers/iio/chemical/Makefile | 1 + > drivers/iio/chemical/sps30.c | 359 ++++++++++++++++++++++++++++++++++ > 3 files changed, 371 insertions(+) > create mode 100644 drivers/iio/chemical/sps30.c [] > +#define pr_fmt(fmt) "sps30: " fmt I don't see its usage ? > +#include <linux/crc8.h> > +#include <linux/delay.h> > +#include <linux/i2c.h> > +#include <linux/iio/buffer.h> > +#include <linux/iio/iio.h> > +#include <linux/iio/sysfs.h> > +#include <linux/iio/trigger_consumer.h> > +#include <linux/iio/triggered_buffer.h> > +#include <linux/module.h> > + > +#define SPS30_CRC8_POLYNOMIAL 0x31 > + > +/* SPS30 commands */ > +#define SPS30_START_MEAS 0x0010 > +#define SPS30_STOP_MEAS 0x0104 > +#define SPS30_RESET 0xd304 > +#define SPS30_READ_DATA_READY_FLAG 0x0202 > +#define SPS30_READ_DATA 0x0300 > +#define SPS30_READ_SERIAL 0xD033 Could you please put a tab and align these macros. #define SPS30_START_MEAS 0x0010 #define SPS30_STOP_MEAS 0x0104 > +static int sps30_write_then_read(struct sps30_state *state, u8 *buf, > + int buf_size, u8 *data, int data_size) > +{ > + /* every two received data bytes are checksummed */ > + u8 tmp[data_size + data_size / 2]; No VLAs! https://lore.kernel.org/lkml/CA+55aFzCG-zNmZwX4A2FQpadafLfEzK6CC=qPXydAacU1RqZWA@mail.gmail.com/ > + int ret, i; > + > + /* > + * Sensor does not support repeated start so instead of > + * sending two i2c messages in a row we just send one by one. > + */ > + ret = i2c_master_send(state->client, buf, buf_size); > + if (ret != buf_size) > + return ret < 0 ? ret : -EIO; > + > + if (!data) > + return 0; > + > + ret = i2c_master_recv(state->client, tmp, sizeof(tmp)); > + if (ret != sizeof(tmp)) > + return ret < 0 ? ret : -EIO; > + > + for (i = 0; i < sizeof(tmp); i += 3) { > + u8 crc = crc8(sps30_crc8_table, &tmp[i], 2, CRC8_INIT_VALUE); > + > + if (crc != tmp[i + 2]) { > + dev_err(&state->client->dev, > + "data integrity check failed\n"); > + return -EIO; > + } > + > + *data++ = tmp[i]; > + *data++ = tmp[i + 1]; > + } > + > + return 0; > +} > + > +static int sps30_do_cmd(struct sps30_state *state, u16 cmd, u8 *data, int size) > +{ > + /* depending on the command up to 3 bytes may be needed for argument */ > + u8 buf[sizeof(cmd) + 3] = { cmd >> 8, cmd }; This is fine, since sizeof returns constant integer expression. > + switch (cmd) { > + case SPS30_START_MEAS: > + buf[2] = 0x03; > + buf[3] = 0x00; > + buf[4] = 0xac; /* precomputed crc */ > + return sps30_write_then_read(state, buf, 5, NULL, 0); > + case SPS30_STOP_MEAS: > + case SPS30_RESET: > + return sps30_write_then_read(state, buf, 2, NULL, 0); > + case SPS30_READ_DATA_READY_FLAG: > + case SPS30_READ_DATA: > + case SPS30_READ_SERIAL: > + return sps30_write_then_read(state, buf, 2, data, size); > + default: > + return -EINVAL; > + }; > +} > +static int sps30_read_raw(struct iio_dev *indio_dev, > + struct iio_chan_spec const *chan, > + int *val, int *val2, long mask) > +{ > + struct sps30_state *state = iio_priv(indio_dev); > + int ret; > + > + switch (mask) { > + case IIO_CHAN_INFO_PROCESSED: > + switch (chan->type) { > + case IIO_MASSCONCENTRATION: > + mutex_lock(&state->lock); > + switch (chan->channel2) { > + case IIO_MOD_PM2p5: I think lock should be placed here > + ret = sps30_do_meas(state, val, val2); ... and unlock here. > + break; > + case IIO_MOD_PM10: > + ret = sps30_do_meas(state, val2, val); > + break; > + default: > + break; > + } > + mutex_unlock(&state->lock); > + if (ret) > + return ret; > + > + return IIO_VAL_INT; > + default: > + return -EINVAL; > + } > + break; > + default: > + return -EINVAL; > + } > +} [] > +static int sps30_probe(struct i2c_client *client) > +{ > + struct iio_dev *indio_dev; > + struct sps30_state *state; > + u8 buf[32] = { }; This is not valid in ISO-C but only in C++. Instead, u8 buf[32] = {0}; > + int ret; > + > + if (!i2c_check_functionality(client->adapter, I2C_FUNC_I2C)) > + return -EOPNOTSUPP; > + > + indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*state)); > + if (!indio_dev) > + return -ENOMEM; > + > + state = iio_priv(indio_dev); > + i2c_set_clientdata(client, indio_dev); > + state->client = client; > + indio_dev->dev.parent = &client->dev; > + indio_dev->info = &sps30_info; > + indio_dev->name = client->name; > + indio_dev->channels = sps30_channels; > + indio_dev->num_channels = ARRAY_SIZE(sps30_channels); > + indio_dev->modes = INDIO_DIRECT_MODE; > + indio_dev->available_scan_masks = sps30_scan_masks; > + > + mutex_init(&state->lock); > + crc8_populate_msb(sps30_crc8_table, SPS30_CRC8_POLYNOMIAL); > + > + /* > + * Power-on-reset causes sensor to produce some glitch on i2c bus > + * and some controllers end up in error state. Recover simply > + * by placing something on the bus. > + */ > + ret = sps30_do_cmd(state, SPS30_RESET, NULL, 0); > + if (ret) { > + dev_err(&client->dev, "failed to reset device\n"); > + return ret; > + } > + usleep_range(2500000, 3500000); Isn't that range too high ? msleep_interruptible ? > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > + > + ret = sps30_do_cmd(state, SPS30_READ_SERIAL, buf, sizeof(buf)); > + if (ret) { > + dev_err(&client->dev, "failed to read serial number\n"); > + return ret; > + } > + dev_info(&client->dev, "serial number: %s\n", buf); > + > + ret = sps30_do_cmd(state, SPS30_START_MEAS, NULL, 0); > + if (ret) { > + dev_err(&client->dev, "failed to start measurement\n"); > + return ret; > + } > + > + ret = devm_iio_triggered_buffer_setup(&client->dev, indio_dev, NULL, > + sps30_trigger_handler, NULL); > + if (ret) > + return ret; > + > + return devm_iio_device_register(&client->dev, indio_dev); > +} > + > +static int sps30_remove(struct i2c_client *client) Perfect candidate for `devm_add_action_or_reset()` ? > +{ > + struct iio_dev *indio_dev = i2c_get_clientdata(client); > + struct sps30_state *state = iio_priv(indio_dev); > + > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > + > + return 0; > +}
On Sun, Nov 25, 2018 at 08:56:59AM +0000, Jonathan Cameron wrote: > On Sat, 24 Nov 2018 23:14:14 +0100 > Tomasz Duszynski <tduszyns@gmail.com> wrote: > > > Add support for Sensirion SPS30 particulate matter sensor. > > > > Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> > A few things inline. > > I'm particularly curious as to why we are ignoring two of the particle > sizes that the sensor seems to capture? > I was thinking about adding first the most common ones i.e PM2.5 and PM10 and the rest of them later on if there's a particular need. On the other hand I can add PM1.0 and PM4.0 now so that we have everything in place once new dust sensors appear on the market. It's seems reasonable to assume they will measure the very same subset of particulates. > Also, a 'potential' race in remove that I'd like us to make > 'obviously' correct rather than requiring hard thought on whether > it would be a problem. > > Thanks, > > Jonathan > > > --- > > drivers/iio/chemical/Kconfig | 11 ++ > > drivers/iio/chemical/Makefile | 1 + > > drivers/iio/chemical/sps30.c | 359 ++++++++++++++++++++++++++++++++++ > > 3 files changed, 371 insertions(+) > > create mode 100644 drivers/iio/chemical/sps30.c > > > > diff --git a/drivers/iio/chemical/Kconfig b/drivers/iio/chemical/Kconfig > > index b8e005be4f87..40057ecf8130 100644 > > --- a/drivers/iio/chemical/Kconfig > > +++ b/drivers/iio/chemical/Kconfig > > @@ -61,6 +61,17 @@ config IAQCORE > > iAQ-Core Continuous/Pulsed VOC (Volatile Organic Compounds) > > sensors > > > > +config SPS30 > > + tristate "SPS30 Particulate Matter sensor" > > + depends on I2C > > + select CRC8 > > + help > > + Say Y here to build support for the Sensirion SPS30 Particulate > > + Matter sensor. > > + > > + To compile this driver as a module, choose M here: the module will > > + be called sps30. > > + > > config VZ89X > > tristate "SGX Sensortech MiCS VZ89X VOC sensor" > > depends on I2C > > diff --git a/drivers/iio/chemical/Makefile b/drivers/iio/chemical/Makefile > > index 2f4c4ba4d781..9f42f4252151 100644 > > --- a/drivers/iio/chemical/Makefile > > +++ b/drivers/iio/chemical/Makefile > > @@ -9,4 +9,5 @@ obj-$(CONFIG_BME680_I2C) += bme680_i2c.o > > obj-$(CONFIG_BME680_SPI) += bme680_spi.o > > obj-$(CONFIG_CCS811) += ccs811.o > > obj-$(CONFIG_IAQCORE) += ams-iaq-core.o > > +obj-$(CONFIG_SPS30) += sps30.o > > obj-$(CONFIG_VZ89X) += vz89x.o > > diff --git a/drivers/iio/chemical/sps30.c b/drivers/iio/chemical/sps30.c > > new file mode 100644 > > index 000000000000..bf802621ae7f > > --- /dev/null > > +++ b/drivers/iio/chemical/sps30.c > > @@ -0,0 +1,359 @@ > > +// SPDX-License-Identifier: GPL-2.0 > > +/* > > + * Sensirion SPS30 Particulate Matter sensor driver > > + * > > + * Copyright (c) Tomasz Duszynski <tduszyns@gmail.com> > > + * > > + * I2C slave address: 0x69 > > + * > > + * TODO: > > + * - support for turning on fan cleaning > > + * - support for reading/setting auto cleaning interval > > + */ > > + > > +#define pr_fmt(fmt) "sps30: " fmt > > + > > +#include <linux/crc8.h> > > +#include <linux/delay.h> > > +#include <linux/i2c.h> > > +#include <linux/iio/buffer.h> > > +#include <linux/iio/iio.h> > > +#include <linux/iio/sysfs.h> > > +#include <linux/iio/trigger_consumer.h> > > +#include <linux/iio/triggered_buffer.h> > > +#include <linux/module.h> > > + > > +#define SPS30_CRC8_POLYNOMIAL 0x31 > > + > > +/* SPS30 commands */ > > +#define SPS30_START_MEAS 0x0010 > > +#define SPS30_STOP_MEAS 0x0104 > > +#define SPS30_RESET 0xd304 > > +#define SPS30_READ_DATA_READY_FLAG 0x0202 > > +#define SPS30_READ_DATA 0x0300 > > +#define SPS30_READ_SERIAL 0xD033 > > + > > +#define SPS30_CHAN(_index, _mod) { \ > > + .type = IIO_MASSCONCENTRATION, \ > > + .modified = 1, \ > > + .channel2 = IIO_MOD_ ## _mod, \ > > + .info_mask_separate = BIT(IIO_CHAN_INFO_PROCESSED), \ > > + .scan_index = _index, \ > > + .scan_type = { \ > > + .sign = 'u', \ > > + .realbits = 12, \ > > + .storagebits = 32, \ > > That is unusual. Why do we need 32 bits to store a 12 bit value? > 16 should be plenty. It'll make a difference to the buffer > sizes if people just want to stream data and don't care about > timestamps as it'll halve the memory usage. Right, I could have picked up a petter values. But I've got at least one valid reason for doing that. Sensor datasheet specifies 0-1000 measurement range but simple tests showed that SPS30 can measure way beyond that. Interestingly, measurements are consistent with third party sensors. So having 12/32 bit setting, especially 32 storagebits protects against future changes in datasheet (which is btw preliminary) i.e updating measurement range. But, I guess that 16 for real and storage bits should be more that enough. > > Also, convention has always been to got for next 8,16,32,64 above > the realbits if there isn't a reason not to (shifting etc) > > How did we end up with 12 bits off the floating point conversion > anyway? Needs some docs. Matter of simple tests. I was able to trigger measurements of over 3000 ug/m3. > > > > + .endianness = IIO_CPU, \ > > + }, \ > > +} > > + > > +enum { > > + PM1p0, /* just a placeholder */ > > + PM2p5, > > + PM4p0, /* just a placeholder */ > > + PM10, > > +}; > > + > > +struct sps30_state { > > + struct i2c_client *client; > > + /* guards against concurrent access to sensor registers */ > > + struct mutex lock; > > +}; > > + > > +DECLARE_CRC8_TABLE(sps30_crc8_table); > > + > > I think you are fine locking wise, but it would be good to add a note > on what locks are expected to be held on entering this function. > > Without locks it's obviously very racey! > Understood. > > +static int sps30_write_then_read(struct sps30_state *state, u8 *buf, > > + int buf_size, u8 *data, int data_size) > > +{ > > + /* every two received data bytes are checksummed */ > > + u8 tmp[data_size + data_size / 2]; > > + int ret, i; > > + > > + /* > > + * Sensor does not support repeated start so instead of > > + * sending two i2c messages in a row we just send one by one. > > + */ > > + ret = i2c_master_send(state->client, buf, buf_size); > > + if (ret != buf_size) > > + return ret < 0 ? ret : -EIO; > > + > > + if (!data) > > + return 0; > > + > > + ret = i2c_master_recv(state->client, tmp, sizeof(tmp)); > > + if (ret != sizeof(tmp)) > > + return ret < 0 ? ret : -EIO; > > + > > + for (i = 0; i < sizeof(tmp); i += 3) { > > + u8 crc = crc8(sps30_crc8_table, &tmp[i], 2, CRC8_INIT_VALUE); > > + > > + if (crc != tmp[i + 2]) { > > + dev_err(&state->client->dev, > > + "data integrity check failed\n"); > > + return -EIO; > > + } > > + > > + *data++ = tmp[i]; > > + *data++ = tmp[i + 1]; > > + } > > + > > + return 0; > > +} > > + > > +static int sps30_do_cmd(struct sps30_state *state, u16 cmd, u8 *data, int size) > > +{ > > + /* depending on the command up to 3 bytes may be needed for argument */ > > + u8 buf[sizeof(cmd) + 3] = { cmd >> 8, cmd }; > > + > > + switch (cmd) { > > + case SPS30_START_MEAS: > > + buf[2] = 0x03; > > + buf[3] = 0x00; > > + buf[4] = 0xac; /* precomputed crc */ > > Could you put that in code and let the compiler do the pre compute? > Might be a little more elegant. > Okay. > > + return sps30_write_then_read(state, buf, 5, NULL, 0); > > + case SPS30_STOP_MEAS: > > + case SPS30_RESET: > > + return sps30_write_then_read(state, buf, 2, NULL, 0); > > + case SPS30_READ_DATA_READY_FLAG: > > + case SPS30_READ_DATA: > > + case SPS30_READ_SERIAL: > > + return sps30_write_then_read(state, buf, 2, data, size); > > + default: > > + return -EINVAL; > > + }; > > +} > > + > > +static int sps30_ieee754_to_int(const u8 *data) > > +{ > > + u32 val = ((u32)data[0] << 24) | ((u32)data[1] << 16) | > > + ((u32)data[2] << 8) | (u32)data[3], > Have a separate > u32 mantissa = (val << 9) >> 9 line. > What is this next line actually doing? Kind of looks like > a mask? If so just mask it with & as more readable. > Do you mean mantissa? We want to get rid of sign bit and 8 exponent bits. > > + mantissa = (val << 9) >> 9; > > + int exp = (val >> 23) - 127; > > + > > + if (!exp && !mantissa) > > + return 0; > > + > > + if (exp < 0) > > + return 0; > > + > > + return (1 << exp) + (mantissa >> (23 - exp)); > > +} > > + > > +static int sps30_do_meas(struct sps30_state *state, int *pm2p5, int *pm10) > > +{ > > + /* > > + * Internally sensor stores measurements in a following manner: > > + * > > + * PM1p0: upper two bytes, crc8, lower two bytes, crc8 > > So there are other particle sizes that this sensor reads? Why > are we mapping them down to just the two channel types? > As said before, introducing PM1.0 and PM4.0 readings seems a reasonable option. > > + * PM2p5: upper two bytes, crc8, lower two bytes, crc8 > > + * PM4p0: upper two bytes, crc8, lower two bytes, crc8 > > + * PM10: upper two bytes, crc8, lower two bytes, crc8 > > + * > > + * What follows next are number concentration measurements and > > + * typical particle size measurement. > > + * > > + * Once data is read from sensor crc bytes are stripped off > > + * hence we need 16 bytes of buffer space. > > + */ > > + int ret, tries = 5; > > + u8 buf[16]; > > + > > + while (tries--) { > > + ret = sps30_do_cmd(state, SPS30_READ_DATA_READY_FLAG, buf, 2); > > + if (ret) > > + return -EIO; > > + > > + /* new measurements ready to be read */ > > + if (buf[1] == 1) > > + break; > > + > > + usleep_range(300000, 400000); > > + } > > + > > + if (!tries) > > + return -ETIMEDOUT; > > + > > + ret = sps30_do_cmd(state, SPS30_READ_DATA, buf, sizeof(buf)); > > + if (ret) > > + return ret; > > + > > + /* > > + * All measurements come in IEEE754 single precision floating point > > + * format but sensor itself is not precise enough (-+ 10% error) > > + * to take full advantage of it. Hence converting result to int > > + * to keep things simple. > > Interesting. We have talked about allowing floating point formats for > sensors the provide them. Would that be beneficial here? > I recall this was discussed once but unfortunately do not remember final conclusion. Anyway, in case of this device datasheet states that readings have maximum error of -+10% in given range which makes me think that using floats here is an overkill. Example, reading of 1000.123412ug/m3 has error of -+100ug/m3. Does it really matter if care about fractional part? Just out of curiosity, if IIO gets support for floats would it be problematic to to add extra channel returning measurements in floats? Or it rather will not fly.. > > + */ > > + *pm2p5 = sps30_ieee754_to_int(&buf[PM2p5 * 4]); > > + *pm10 = sps30_ieee754_to_int(&buf[PM10 * 4]); > > + > > + return 0; > > +} > > + > > +static irqreturn_t sps30_trigger_handler(int irq, void *p) > > +{ > > + struct iio_poll_func *pf = p; > > + struct iio_dev *indio_dev = pf->indio_dev; > > + struct sps30_state *state = iio_priv(indio_dev); > > + u32 buf[4]; /* PM2p5, PM10, timestamp */ > > + int ret; > > + > > + mutex_lock(&state->lock); > > + ret = sps30_do_meas(state, &buf[0], &buf[1]); > > + mutex_unlock(&state->lock); > > + if (ret < 0) > > + goto err; > > + > > + iio_push_to_buffers_with_timestamp(indio_dev, buf, > > + iio_get_time_ns(indio_dev)); > > +err: > > + iio_trigger_notify_done(indio_dev->trig); > > + > > + return IRQ_HANDLED; > > +} > > + > > +static int sps30_read_raw(struct iio_dev *indio_dev, > > + struct iio_chan_spec const *chan, > > + int *val, int *val2, long mask) > > +{ > > + struct sps30_state *state = iio_priv(indio_dev); > > + int ret; > > + > > + switch (mask) { > > + case IIO_CHAN_INFO_PROCESSED: > > + switch (chan->type) { > > + case IIO_MASSCONCENTRATION: > > + mutex_lock(&state->lock); > > + switch (chan->channel2) { > > + case IIO_MOD_PM2p5: > > + ret = sps30_do_meas(state, val, val2); > > + break; > > + case IIO_MOD_PM10: > > + ret = sps30_do_meas(state, val2, val); > > + break; > > + default: > > + break; > > + } > > + mutex_unlock(&state->lock); > > + if (ret) > > + return ret; > > + > > + return IIO_VAL_INT; > > + default: > > + return -EINVAL; > > + } > > + break; > > + default: > You can't get here. Is this a warning suppression? > If so just add a comment saying so to prevent it being removed > by someone else later. > Okay. > > + return -EINVAL; > > + } > > +} > > + > > +static const struct iio_info sps30_info = { > > + .read_raw = sps30_read_raw, > > +}; > > + > From a readability point of view, it would be helpful to pull > the macro SPS30_CHAN down here in the code so we don't > need to go jumping around to check what it is doing. > Okay. > > +static const struct iio_chan_spec sps30_channels[] = { > > + SPS30_CHAN(0, PM2p5), > > + SPS30_CHAN(1, PM10), > > + IIO_CHAN_SOFT_TIMESTAMP(2), > > +}; > > + > > +static const unsigned long sps30_scan_masks[] = { 0x03, 0x00 }; > > + > > +static int sps30_probe(struct i2c_client *client) > > +{ > > + struct iio_dev *indio_dev; > > + struct sps30_state *state; > > + u8 buf[32] = { }; > > + int ret; > > + > > + if (!i2c_check_functionality(client->adapter, I2C_FUNC_I2C)) > > + return -EOPNOTSUPP; > > + > > + indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*state)); > > + if (!indio_dev) > > + return -ENOMEM; > > + > > + state = iio_priv(indio_dev); > > + i2c_set_clientdata(client, indio_dev); > > + state->client = client; > > + indio_dev->dev.parent = &client->dev; > > + indio_dev->info = &sps30_info; > > + indio_dev->name = client->name; > > + indio_dev->channels = sps30_channels; > > + indio_dev->num_channels = ARRAY_SIZE(sps30_channels); > > + indio_dev->modes = INDIO_DIRECT_MODE; > > + indio_dev->available_scan_masks = sps30_scan_masks; > > + > > + mutex_init(&state->lock); > > + crc8_populate_msb(sps30_crc8_table, SPS30_CRC8_POLYNOMIAL); > > + > > + /* > > + * Power-on-reset causes sensor to produce some glitch on i2c bus > > + * and some controllers end up in error state. Recover simply > > + * by placing something on the bus. > > + */ > > + ret = sps30_do_cmd(state, SPS30_RESET, NULL, 0); > > + if (ret) { > > + dev_err(&client->dev, "failed to reset device\n"); > > + return ret; > > + } > > + usleep_range(2500000, 3500000); > > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > > Talk me through this logic. We stop it then pretty much immediately > start it again? Needs a comment. > The idea is to send some message after resetting sensor so that i2c controller recovers from error state. I decided to send STOP_MEAS as it's a NOP in this case. I'll try to do more testing with other SPS30s and perhaps different boards. > > + > > + ret = sps30_do_cmd(state, SPS30_READ_SERIAL, buf, sizeof(buf)); > > + if (ret) { > > + dev_err(&client->dev, "failed to read serial number\n"); > > + return ret; > > + } > > + dev_info(&client->dev, "serial number: %s\n", buf); > > + > > + ret = sps30_do_cmd(state, SPS30_START_MEAS, NULL, 0); > > + if (ret) { > > This is not unwound on error. See comment on remove race below. > > > + dev_err(&client->dev, "failed to start measurement\n"); > > + return ret; > > + } > > + > > + ret = devm_iio_triggered_buffer_setup(&client->dev, indio_dev, NULL, > > + sps30_trigger_handler, NULL); > > + if (ret) > > + return ret; > > + > > + return devm_iio_device_register(&client->dev, indio_dev); > > +} > > + > > +static int sps30_remove(struct i2c_client *client) > > +{ > > + struct iio_dev *indio_dev = i2c_get_clientdata(client); > > + struct sps30_state *state = iio_priv(indio_dev); > > + > > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > This looks like a race to me. > Right, this needs fixing. > You turn off the measurements before removing the interface to them. > It's certainly not in the 'obviously' right category. > > As such I would either use a devm action to do this stop, > or not use the managed interfaces for everything in probe > after the equivalent start. > The devm_add_action_or_reset would be the cleanest option I think.. > Will also fix the cleanup on error in probe. > > > + > > + return 0; > > +} > > + > > +static const struct i2c_device_id sps30_id[] = { > > + { "sps30" }, > > + { } > > +}; > > +MODULE_DEVICE_TABLE(i2c, sps30_id); > > + > > +static const struct of_device_id sps30_of_match[] = { > > + { .compatible = "sensirion,sps30" }, > > + { } > > +}; > > +MODULE_DEVICE_TABLE(of, sps30_of_match); > > + > > +static struct i2c_driver sps30_driver = { > > + .driver = { > > + .name = "sps30", > > + .of_match_table = sps30_of_match, > > + }, > > + .id_table = sps30_id, > > + .probe_new = sps30_probe, > > + .remove = sps30_remove, > > +}; > > +module_i2c_driver(sps30_driver); > > + > > +MODULE_AUTHOR("Tomasz Duszynski <tduszyns@gmail.com>"); > > +MODULE_DESCRIPTION("Sensirion SPS30 particulate matter sensor driver"); > > +MODULE_LICENSE("GPL v2"); >
On Sun, Nov 25, 2018 at 04:14:34PM +0530, Himanshu Jha wrote: > On Sat, Nov 24, 2018 at 11:14:14PM +0100, Tomasz Duszynski wrote: > > Add support for Sensirion SPS30 particulate matter sensor. > > > > Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> > > --- > > drivers/iio/chemical/Kconfig | 11 ++ > > drivers/iio/chemical/Makefile | 1 + > > drivers/iio/chemical/sps30.c | 359 ++++++++++++++++++++++++++++++++++ > > 3 files changed, 371 insertions(+) > > create mode 100644 drivers/iio/chemical/sps30.c > > [] > > > +#define pr_fmt(fmt) "sps30: " fmt > > I don't see its usage ? > Hint: checkout how dev_err() is defined. > > +#include <linux/crc8.h> > > +#include <linux/delay.h> > > +#include <linux/i2c.h> > > +#include <linux/iio/buffer.h> > > +#include <linux/iio/iio.h> > > +#include <linux/iio/sysfs.h> > > +#include <linux/iio/trigger_consumer.h> > > +#include <linux/iio/triggered_buffer.h> > > +#include <linux/module.h> > > + > > +#define SPS30_CRC8_POLYNOMIAL 0x31 > > + > > +/* SPS30 commands */ > > +#define SPS30_START_MEAS 0x0010 > > +#define SPS30_STOP_MEAS 0x0104 > > +#define SPS30_RESET 0xd304 > > +#define SPS30_READ_DATA_READY_FLAG 0x0202 > > +#define SPS30_READ_DATA 0x0300 > > +#define SPS30_READ_SERIAL 0xD033 > > Could you please put a tab and align these macros. > > #define SPS30_START_MEAS 0x0010 > #define SPS30_STOP_MEAS 0x0104 > In my opinion this sort of alignment does not pay off in the long run. Adding a new definition, a slightly longer one perhaps, can easily break formatting. So I would stay with current one. > > > +static int sps30_write_then_read(struct sps30_state *state, u8 *buf, > > + int buf_size, u8 *data, int data_size) > > +{ > > + /* every two received data bytes are checksummed */ > > + u8 tmp[data_size + data_size / 2]; > > No VLAs! > > https://lore.kernel.org/lkml/CA+55aFzCG-zNmZwX4A2FQpadafLfEzK6CC=qPXydAacU1RqZWA@mail.gmail.com/ > Looks like -Wvla is some fairly recent addition to KBUILD_CFLAGS. > > + int ret, i; > > + > > + /* > > + * Sensor does not support repeated start so instead of > > + * sending two i2c messages in a row we just send one by one. > > + */ > > + ret = i2c_master_send(state->client, buf, buf_size); > > + if (ret != buf_size) > > + return ret < 0 ? ret : -EIO; > > + > > + if (!data) > > + return 0; > > + > > + ret = i2c_master_recv(state->client, tmp, sizeof(tmp)); > > + if (ret != sizeof(tmp)) > > + return ret < 0 ? ret : -EIO; > > + > > + for (i = 0; i < sizeof(tmp); i += 3) { > > + u8 crc = crc8(sps30_crc8_table, &tmp[i], 2, CRC8_INIT_VALUE); > > + > > + if (crc != tmp[i + 2]) { > > + dev_err(&state->client->dev, > > + "data integrity check failed\n"); > > + return -EIO; > > + } > > + > > + *data++ = tmp[i]; > > + *data++ = tmp[i + 1]; > > + } > > + > > + return 0; > > +} > > + > > +static int sps30_do_cmd(struct sps30_state *state, u16 cmd, u8 *data, int size) > > +{ > > + /* depending on the command up to 3 bytes may be needed for argument */ > > + u8 buf[sizeof(cmd) + 3] = { cmd >> 8, cmd }; > > This is fine, since sizeof returns constant integer expression. > > > + switch (cmd) { > > + case SPS30_START_MEAS: > > + buf[2] = 0x03; > > + buf[3] = 0x00; > > + buf[4] = 0xac; /* precomputed crc */ > > + return sps30_write_then_read(state, buf, 5, NULL, 0); > > + case SPS30_STOP_MEAS: > > + case SPS30_RESET: > > + return sps30_write_then_read(state, buf, 2, NULL, 0); > > + case SPS30_READ_DATA_READY_FLAG: > > + case SPS30_READ_DATA: > > + case SPS30_READ_SERIAL: > > + return sps30_write_then_read(state, buf, 2, data, size); > > + default: > > + return -EINVAL; > > + }; > > +} > > > > +static int sps30_read_raw(struct iio_dev *indio_dev, > > + struct iio_chan_spec const *chan, > > + int *val, int *val2, long mask) > > +{ > > + struct sps30_state *state = iio_priv(indio_dev); > > + int ret; > > + > > + switch (mask) { > > + case IIO_CHAN_INFO_PROCESSED: > > + switch (chan->type) { > > + case IIO_MASSCONCENTRATION: > > + mutex_lock(&state->lock); > > + switch (chan->channel2) { > > + case IIO_MOD_PM2p5: > > I think lock should be placed here > > > + ret = sps30_do_meas(state, val, val2); > > ... and unlock here. > > > + break; > > + case IIO_MOD_PM10: > > + ret = sps30_do_meas(state, val2, val); > > + break; > > + default: > > + break; > > + } > > + mutex_unlock(&state->lock); > > + if (ret) > > + return ret; > > + > > + return IIO_VAL_INT; > > + default: > > + return -EINVAL; > > + } > > + break; > > + default: > > + return -EINVAL; > > + } > > +} > > [] > > > +static int sps30_probe(struct i2c_client *client) > > +{ > > + struct iio_dev *indio_dev; > > + struct sps30_state *state; > > + u8 buf[32] = { }; > > This is not valid in ISO-C but only in C++. > > Instead, > > u8 buf[32] = {0}; > > > + int ret; > > + > > + if (!i2c_check_functionality(client->adapter, I2C_FUNC_I2C)) > > + return -EOPNOTSUPP; > > + > > + indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*state)); > > + if (!indio_dev) > > + return -ENOMEM; > > + > > + state = iio_priv(indio_dev); > > + i2c_set_clientdata(client, indio_dev); > > + state->client = client; > > + indio_dev->dev.parent = &client->dev; > > + indio_dev->info = &sps30_info; > > + indio_dev->name = client->name; > > + indio_dev->channels = sps30_channels; > > + indio_dev->num_channels = ARRAY_SIZE(sps30_channels); > > + indio_dev->modes = INDIO_DIRECT_MODE; > > + indio_dev->available_scan_masks = sps30_scan_masks; > > + > > + mutex_init(&state->lock); > > + crc8_populate_msb(sps30_crc8_table, SPS30_CRC8_POLYNOMIAL); > > + > > + /* > > + * Power-on-reset causes sensor to produce some glitch on i2c bus > > + * and some controllers end up in error state. Recover simply > > + * by placing something on the bus. > > + */ > > + ret = sps30_do_cmd(state, SPS30_RESET, NULL, 0); > > + if (ret) { > > + dev_err(&client->dev, "failed to reset device\n"); > > + return ret; > > + } > > + usleep_range(2500000, 3500000); > > Isn't that range too high ? > msleep_interruptible ? > Might be. > > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > > + > > + ret = sps30_do_cmd(state, SPS30_READ_SERIAL, buf, sizeof(buf)); > > + if (ret) { > > + dev_err(&client->dev, "failed to read serial number\n"); > > + return ret; > > + } > > + dev_info(&client->dev, "serial number: %s\n", buf); > > + > > + ret = sps30_do_cmd(state, SPS30_START_MEAS, NULL, 0); > > + if (ret) { > > + dev_err(&client->dev, "failed to start measurement\n"); > > + return ret; > > + } > > + > > + ret = devm_iio_triggered_buffer_setup(&client->dev, indio_dev, NULL, > > + sps30_trigger_handler, NULL); > > + if (ret) > > + return ret; > > + > > + return devm_iio_device_register(&client->dev, indio_dev); > > +} > > + > > +static int sps30_remove(struct i2c_client *client) > > Perfect candidate for `devm_add_action_or_reset()` ? > > > +{ > > + struct iio_dev *indio_dev = i2c_get_clientdata(client); > > + struct sps30_state *state = iio_priv(indio_dev); > > + > > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > > + > > + return 0; > > +} > > > -- > Himanshu Jha > Undergraduate Student > Department of Electronics & Communication > Guru Tegh Bahadur Institute of Technology
On Sun, 25 Nov 2018 20:05:09 +0100 Tomasz Duszynski <tduszyns@gmail.com> wrote: > On Sun, Nov 25, 2018 at 08:56:59AM +0000, Jonathan Cameron wrote: > > On Sat, 24 Nov 2018 23:14:14 +0100 > > Tomasz Duszynski <tduszyns@gmail.com> wrote: > > > > > Add support for Sensirion SPS30 particulate matter sensor. > > > > > > Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> > > A few things inline. > > > > I'm particularly curious as to why we are ignoring two of the particle > > sizes that the sensor seems to capture? > > > > I was thinking about adding first the most common ones i.e PM2.5 and > PM10 and the rest of them later on if there's a particular need. > > On the other hand I can add PM1.0 and PM4.0 now so that we have > everything in place once new dust sensors appear on the market. I would. I do hope there don't turn out to be 100s of different views of what these values should be though. The various standards should prevent that even if people tuck in one or two extra just because they could. > > It's seems reasonable to assume they will measure the very same > subset of particulates. > > > Also, a 'potential' race in remove that I'd like us to make > > 'obviously' correct rather than requiring hard thought on whether > > it would be a problem. > > > > Thanks, > > > > Jonathan > > > > > --- > > > drivers/iio/chemical/Kconfig | 11 ++ > > > drivers/iio/chemical/Makefile | 1 + > > > drivers/iio/chemical/sps30.c | 359 ++++++++++++++++++++++++++++++++++ > > > 3 files changed, 371 insertions(+) > > > create mode 100644 drivers/iio/chemical/sps30.c > > > > > > diff --git a/drivers/iio/chemical/Kconfig b/drivers/iio/chemical/Kconfig > > > index b8e005be4f87..40057ecf8130 100644 > > > --- a/drivers/iio/chemical/Kconfig > > > +++ b/drivers/iio/chemical/Kconfig > > > @@ -61,6 +61,17 @@ config IAQCORE > > > iAQ-Core Continuous/Pulsed VOC (Volatile Organic Compounds) > > > sensors > > > > > > +config SPS30 > > > + tristate "SPS30 Particulate Matter sensor" > > > + depends on I2C > > > + select CRC8 > > > + help > > > + Say Y here to build support for the Sensirion SPS30 Particulate > > > + Matter sensor. > > > + > > > + To compile this driver as a module, choose M here: the module will > > > + be called sps30. > > > + > > > config VZ89X > > > tristate "SGX Sensortech MiCS VZ89X VOC sensor" > > > depends on I2C > > > diff --git a/drivers/iio/chemical/Makefile b/drivers/iio/chemical/Makefile > > > index 2f4c4ba4d781..9f42f4252151 100644 > > > --- a/drivers/iio/chemical/Makefile > > > +++ b/drivers/iio/chemical/Makefile > > > @@ -9,4 +9,5 @@ obj-$(CONFIG_BME680_I2C) += bme680_i2c.o > > > obj-$(CONFIG_BME680_SPI) += bme680_spi.o > > > obj-$(CONFIG_CCS811) += ccs811.o > > > obj-$(CONFIG_IAQCORE) += ams-iaq-core.o > > > +obj-$(CONFIG_SPS30) += sps30.o > > > obj-$(CONFIG_VZ89X) += vz89x.o > > > diff --git a/drivers/iio/chemical/sps30.c b/drivers/iio/chemical/sps30.c > > > new file mode 100644 > > > index 000000000000..bf802621ae7f > > > --- /dev/null > > > +++ b/drivers/iio/chemical/sps30.c > > > @@ -0,0 +1,359 @@ > > > +// SPDX-License-Identifier: GPL-2.0 > > > +/* > > > + * Sensirion SPS30 Particulate Matter sensor driver > > > + * > > > + * Copyright (c) Tomasz Duszynski <tduszyns@gmail.com> > > > + * > > > + * I2C slave address: 0x69 > > > + * > > > + * TODO: > > > + * - support for turning on fan cleaning > > > + * - support for reading/setting auto cleaning interval > > > + */ > > > + > > > +#define pr_fmt(fmt) "sps30: " fmt > > > + > > > +#include <linux/crc8.h> > > > +#include <linux/delay.h> > > > +#include <linux/i2c.h> > > > +#include <linux/iio/buffer.h> > > > +#include <linux/iio/iio.h> > > > +#include <linux/iio/sysfs.h> > > > +#include <linux/iio/trigger_consumer.h> > > > +#include <linux/iio/triggered_buffer.h> > > > +#include <linux/module.h> > > > + > > > +#define SPS30_CRC8_POLYNOMIAL 0x31 > > > + > > > +/* SPS30 commands */ > > > +#define SPS30_START_MEAS 0x0010 > > > +#define SPS30_STOP_MEAS 0x0104 > > > +#define SPS30_RESET 0xd304 > > > +#define SPS30_READ_DATA_READY_FLAG 0x0202 > > > +#define SPS30_READ_DATA 0x0300 > > > +#define SPS30_READ_SERIAL 0xD033 > > > + > > > +#define SPS30_CHAN(_index, _mod) { \ > > > + .type = IIO_MASSCONCENTRATION, \ > > > + .modified = 1, \ > > > + .channel2 = IIO_MOD_ ## _mod, \ > > > + .info_mask_separate = BIT(IIO_CHAN_INFO_PROCESSED), \ > > > + .scan_index = _index, \ > > > + .scan_type = { \ > > > + .sign = 'u', \ > > > + .realbits = 12, \ > > > + .storagebits = 32, \ > > > > That is unusual. Why do we need 32 bits to store a 12 bit value? > > 16 should be plenty. It'll make a difference to the buffer > > sizes if people just want to stream data and don't care about > > timestamps as it'll halve the memory usage. > > Right, I could have picked up a petter values. But I've got at least one > valid reason for doing that. Sensor datasheet specifies 0-1000 > measurement range but simple tests showed that SPS30 can measure way beyond > that. Interestingly, measurements are consistent with third party sensors. I'm guessing there are certification bodies for this sort of thing. They may only have paid for the low end to be certified (or there may be no official test for higher levels?) > > So having 12/32 bit setting, especially 32 storagebits protects against > future changes in datasheet (which is btw preliminary) i.e updating > measurement range. Not really because userspace is going to assume the value is 12 bits and will probably mask it as such, thus any change requires userspace to cope with it. Once you are doing that, might as well just change the padding as well. > > But, I guess that 16 for real and storage bits should be more > that enough. Feels like it to me as well. > > > > > Also, convention has always been to got for next 8,16,32,64 above > > the realbits if there isn't a reason not to (shifting etc) > > > > How did we end up with 12 bits off the floating point conversion > > anyway? Needs some docs. > > Matter of simple tests. I was able to trigger measurements of over > 3000 ug/m3. Hmm. So potentially it will give readings with more? If so we should work out a hard justification for that limit. Userspace will mask against it (as the rest of the bits may be garbage - we don't force them to 0 in other drivers and they often contain meta data if not actual garbage). > > > > > > > > + .endianness = IIO_CPU, \ > > > + }, \ > > > +} > > > + > > > +enum { > > > + PM1p0, /* just a placeholder */ > > > + PM2p5, > > > + PM4p0, /* just a placeholder */ > > > + PM10, > > > +}; > > > + > > > +struct sps30_state { > > > + struct i2c_client *client; > > > + /* guards against concurrent access to sensor registers */ > > > + struct mutex lock; > > > +}; > > > + > > > +DECLARE_CRC8_TABLE(sps30_crc8_table); > > > + > > > > I think you are fine locking wise, but it would be good to add a note > > on what locks are expected to be held on entering this function. > > > > Without locks it's obviously very racey! > > > > Understood. > > > > +static int sps30_write_then_read(struct sps30_state *state, u8 *buf, > > > + int buf_size, u8 *data, int data_size) > > > +{ > > > + /* every two received data bytes are checksummed */ > > > + u8 tmp[data_size + data_size / 2]; > > > + int ret, i; > > > + > > > + /* > > > + * Sensor does not support repeated start so instead of > > > + * sending two i2c messages in a row we just send one by one. > > > + */ > > > + ret = i2c_master_send(state->client, buf, buf_size); > > > + if (ret != buf_size) > > > + return ret < 0 ? ret : -EIO; > > > + > > > + if (!data) > > > + return 0; > > > + > > > + ret = i2c_master_recv(state->client, tmp, sizeof(tmp)); > > > + if (ret != sizeof(tmp)) > > > + return ret < 0 ? ret : -EIO; > > > + > > > + for (i = 0; i < sizeof(tmp); i += 3) { > > > + u8 crc = crc8(sps30_crc8_table, &tmp[i], 2, CRC8_INIT_VALUE); > > > + > > > + if (crc != tmp[i + 2]) { > > > + dev_err(&state->client->dev, > > > + "data integrity check failed\n"); > > > + return -EIO; > > > + } > > > + > > > + *data++ = tmp[i]; > > > + *data++ = tmp[i + 1]; > > > + } > > > + > > > + return 0; > > > +} > > > + > > > +static int sps30_do_cmd(struct sps30_state *state, u16 cmd, u8 *data, int size) > > > +{ > > > + /* depending on the command up to 3 bytes may be needed for argument */ > > > + u8 buf[sizeof(cmd) + 3] = { cmd >> 8, cmd }; > > > + > > > + switch (cmd) { > > > + case SPS30_START_MEAS: > > > + buf[2] = 0x03; > > > + buf[3] = 0x00; > > > + buf[4] = 0xac; /* precomputed crc */ > > > > Could you put that in code and let the compiler do the pre compute? > > Might be a little more elegant. > > > > Okay. > > > > + return sps30_write_then_read(state, buf, 5, NULL, 0); > > > + case SPS30_STOP_MEAS: > > > + case SPS30_RESET: > > > + return sps30_write_then_read(state, buf, 2, NULL, 0); > > > + case SPS30_READ_DATA_READY_FLAG: > > > + case SPS30_READ_DATA: > > > + case SPS30_READ_SERIAL: > > > + return sps30_write_then_read(state, buf, 2, data, size); > > > + default: > > > + return -EINVAL; > > > + }; > > > +} > > > + > > > +static int sps30_ieee754_to_int(const u8 *data) > > > +{ > > > + u32 val = ((u32)data[0] << 24) | ((u32)data[1] << 16) | > > > + ((u32)data[2] << 8) | (u32)data[3], > > Have a separate > > u32 mantissa = (val << 9) >> 9 line. > > What is this next line actually doing? Kind of looks like > > a mask? If so just mask it with & as more readable. > > > > Do you mean mantissa? We want to get rid of sign bit and 8 exponent bits. Got it, but the above is the same as. val & 0x7ffffff; I think... Shifting like this immediately made me think you were manually sign extending (but it's unsigned so obviously not). It's a mask to extract just the mantissa, so code it as one. > > > > + mantissa = (val << 9) >> 9; > > > + int exp = (val >> 23) - 127; > > > + > > > + if (!exp && !mantissa) > > > + return 0; > > > + > > > + if (exp < 0) > > > + return 0; > > > + > > > + return (1 << exp) + (mantissa >> (23 - exp)); > > > +} > > > + > > > +static int sps30_do_meas(struct sps30_state *state, int *pm2p5, int *pm10) > > > +{ > > > + /* > > > + * Internally sensor stores measurements in a following manner: > > > + * > > > + * PM1p0: upper two bytes, crc8, lower two bytes, crc8 > > > > So there are other particle sizes that this sensor reads? Why > > are we mapping them down to just the two channel types? > > > > As said before, introducing PM1.0 and PM4.0 readings seems > a reasonable option. Go for it. Userspace who doesn't care won't read them. > > > > + * PM2p5: upper two bytes, crc8, lower two bytes, crc8 > > > + * PM4p0: upper two bytes, crc8, lower two bytes, crc8 > > > + * PM10: upper two bytes, crc8, lower two bytes, crc8 > > > + * > > > + * What follows next are number concentration measurements and > > > + * typical particle size measurement. > > > + * > > > + * Once data is read from sensor crc bytes are stripped off > > > + * hence we need 16 bytes of buffer space. > > > + */ > > > + int ret, tries = 5; > > > + u8 buf[16]; > > > + > > > + while (tries--) { > > > + ret = sps30_do_cmd(state, SPS30_READ_DATA_READY_FLAG, buf, 2); > > > + if (ret) > > > + return -EIO; > > > + > > > + /* new measurements ready to be read */ > > > + if (buf[1] == 1) > > > + break; > > > + > > > + usleep_range(300000, 400000); > > > + } > > > + > > > + if (!tries) > > > + return -ETIMEDOUT; > > > + > > > + ret = sps30_do_cmd(state, SPS30_READ_DATA, buf, sizeof(buf)); > > > + if (ret) > > > + return ret; > > > + > > > + /* > > > + * All measurements come in IEEE754 single precision floating point > > > + * format but sensor itself is not precise enough (-+ 10% error) > > > + * to take full advantage of it. Hence converting result to int > > > + * to keep things simple. > > > > Interesting. We have talked about allowing floating point formats for > > sensors the provide them. Would that be beneficial here? > > > > I recall this was discussed once but unfortunately do not > remember final conclusion. Anyway, in case of this device datasheet > states that readings have maximum error of -+10% in given range which > makes me think that using floats here is an overkill. > > Example, reading of 1000.123412ug/m3 has error of -+100ug/m3. > Does it really matter if care about fractional part? *laughs*. It does make you wonder why they ended up as floating point unless it is sensitive at very low levels? Note I know nothing about particle sensing at all! > > Just out of curiosity, if IIO gets support for floats would it > be problematic to to add extra channel returning measurements in floats? > Or it rather will not fly.. It's hard for userspace to interpret the case of two channels measuring the same thing. So it could be done (and we have once or twice done this) but it's messy. > > > > + */ > > > + *pm2p5 = sps30_ieee754_to_int(&buf[PM2p5 * 4]); > > > + *pm10 = sps30_ieee754_to_int(&buf[PM10 * 4]); > > > + > > > + return 0; > > > +} > > > + > > > +static irqreturn_t sps30_trigger_handler(int irq, void *p) > > > +{ > > > + struct iio_poll_func *pf = p; > > > + struct iio_dev *indio_dev = pf->indio_dev; > > > + struct sps30_state *state = iio_priv(indio_dev); > > > + u32 buf[4]; /* PM2p5, PM10, timestamp */ > > > + int ret; > > > + > > > + mutex_lock(&state->lock); > > > + ret = sps30_do_meas(state, &buf[0], &buf[1]); > > > + mutex_unlock(&state->lock); > > > + if (ret < 0) > > > + goto err; > > > + > > > + iio_push_to_buffers_with_timestamp(indio_dev, buf, > > > + iio_get_time_ns(indio_dev)); > > > +err: > > > + iio_trigger_notify_done(indio_dev->trig); > > > + > > > + return IRQ_HANDLED; > > > +} > > > + > > > +static int sps30_read_raw(struct iio_dev *indio_dev, > > > + struct iio_chan_spec const *chan, > > > + int *val, int *val2, long mask) > > > +{ > > > + struct sps30_state *state = iio_priv(indio_dev); > > > + int ret; > > > + > > > + switch (mask) { > > > + case IIO_CHAN_INFO_PROCESSED: > > > + switch (chan->type) { > > > + case IIO_MASSCONCENTRATION: > > > + mutex_lock(&state->lock); > > > + switch (chan->channel2) { > > > + case IIO_MOD_PM2p5: > > > + ret = sps30_do_meas(state, val, val2); > > > + break; > > > + case IIO_MOD_PM10: > > > + ret = sps30_do_meas(state, val2, val); > > > + break; > > > + default: > > > + break; > > > + } > > > + mutex_unlock(&state->lock); > > > + if (ret) > > > + return ret; > > > + > > > + return IIO_VAL_INT; > > > + default: > > > + return -EINVAL; > > > + } > > > + break; > > > + default: > > You can't get here. Is this a warning suppression? > > If so just add a comment saying so to prevent it being removed > > by someone else later. > > > > Okay. > > > > + return -EINVAL; > > > + } > > > +} > > > + > > > +static const struct iio_info sps30_info = { > > > + .read_raw = sps30_read_raw, > > > +}; > > > + > > From a readability point of view, it would be helpful to pull > > the macro SPS30_CHAN down here in the code so we don't > > need to go jumping around to check what it is doing. > > > > Okay. > > > > +static const struct iio_chan_spec sps30_channels[] = { > > > + SPS30_CHAN(0, PM2p5), > > > + SPS30_CHAN(1, PM10), > > > + IIO_CHAN_SOFT_TIMESTAMP(2), > > > +}; > > > + > > > +static const unsigned long sps30_scan_masks[] = { 0x03, 0x00 }; > > > + > > > +static int sps30_probe(struct i2c_client *client) > > > +{ > > > + struct iio_dev *indio_dev; > > > + struct sps30_state *state; > > > + u8 buf[32] = { }; > > > + int ret; > > > + > > > + if (!i2c_check_functionality(client->adapter, I2C_FUNC_I2C)) > > > + return -EOPNOTSUPP; > > > + > > > + indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*state)); > > > + if (!indio_dev) > > > + return -ENOMEM; > > > + > > > + state = iio_priv(indio_dev); > > > + i2c_set_clientdata(client, indio_dev); > > > + state->client = client; > > > + indio_dev->dev.parent = &client->dev; > > > + indio_dev->info = &sps30_info; > > > + indio_dev->name = client->name; > > > + indio_dev->channels = sps30_channels; > > > + indio_dev->num_channels = ARRAY_SIZE(sps30_channels); > > > + indio_dev->modes = INDIO_DIRECT_MODE; > > > + indio_dev->available_scan_masks = sps30_scan_masks; > > > + > > > + mutex_init(&state->lock); > > > + crc8_populate_msb(sps30_crc8_table, SPS30_CRC8_POLYNOMIAL); > > > + > > > + /* > > > + * Power-on-reset causes sensor to produce some glitch on i2c bus > > > + * and some controllers end up in error state. Recover simply > > > + * by placing something on the bus. > > > + */ > > > + ret = sps30_do_cmd(state, SPS30_RESET, NULL, 0); > > > + if (ret) { > > > + dev_err(&client->dev, "failed to reset device\n"); > > > + return ret; > > > + } > > > + usleep_range(2500000, 3500000); > > > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > > > > Talk me through this logic. We stop it then pretty much immediately > > start it again? Needs a comment. > > > > The idea is to send some message after resetting sensor so that > i2c controller recovers from error state. I decided to send STOP_MEAS > as it's a NOP in this case. I'll try to do more testing with other > SPS30s and perhaps different boards. Ah. Makes sense. Just add a comment to the code saying this and it's fine. > > > > + > > > + ret = sps30_do_cmd(state, SPS30_READ_SERIAL, buf, sizeof(buf)); > > > + if (ret) { > > > + dev_err(&client->dev, "failed to read serial number\n"); > > > + return ret; > > > + } > > > + dev_info(&client->dev, "serial number: %s\n", buf); > > > + > > > + ret = sps30_do_cmd(state, SPS30_START_MEAS, NULL, 0); > > > + if (ret) { > > > > This is not unwound on error. See comment on remove race below. > > > > > + dev_err(&client->dev, "failed to start measurement\n"); > > > + return ret; > > > + } > > > + > > > + ret = devm_iio_triggered_buffer_setup(&client->dev, indio_dev, NULL, > > > + sps30_trigger_handler, NULL); > > > + if (ret) > > > + return ret; > > > + > > > + return devm_iio_device_register(&client->dev, indio_dev); > > > +} > > > + > > > +static int sps30_remove(struct i2c_client *client) > > > +{ > > > + struct iio_dev *indio_dev = i2c_get_clientdata(client); > > > + struct sps30_state *state = iio_priv(indio_dev); > > > + > > > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > > This looks like a race to me. > > > > Right, this needs fixing. > > > You turn off the measurements before removing the interface to them. > > It's certainly not in the 'obviously' right category. > > > > As such I would either use a devm action to do this stop, > > or not use the managed interfaces for everything in probe > > after the equivalent start. > > The devm_add_action_or_reset would be the cleanest option I think.. > > Will also fix the cleanup on error in probe. > > > > > + > > > + return 0; > > > +} > > > + > > > +static const struct i2c_device_id sps30_id[] = { > > > + { "sps30" }, > > > + { } > > > +}; > > > +MODULE_DEVICE_TABLE(i2c, sps30_id); > > > + > > > +static const struct of_device_id sps30_of_match[] = { > > > + { .compatible = "sensirion,sps30" }, > > > + { } > > > +}; > > > +MODULE_DEVICE_TABLE(of, sps30_of_match); > > > + > > > +static struct i2c_driver sps30_driver = { > > > + .driver = { > > > + .name = "sps30", > > > + .of_match_table = sps30_of_match, > > > + }, > > > + .id_table = sps30_id, > > > + .probe_new = sps30_probe, > > > + .remove = sps30_remove, > > > +}; > > > +module_i2c_driver(sps30_driver); > > > + > > > +MODULE_AUTHOR("Tomasz Duszynski <tduszyns@gmail.com>"); > > > +MODULE_DESCRIPTION("Sensirion SPS30 particulate matter sensor driver"); > > > +MODULE_LICENSE("GPL v2"); > >
On Mon, 26 Nov 2018 21:48:07 +0100 Tomasz Duszynski <tduszyns@gmail.com> wrote: > On Sun, Nov 25, 2018 at 04:14:34PM +0530, Himanshu Jha wrote: > > On Sat, Nov 24, 2018 at 11:14:14PM +0100, Tomasz Duszynski wrote: > > > Add support for Sensirion SPS30 particulate matter sensor. > > > > > > Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> > > > --- > > > drivers/iio/chemical/Kconfig | 11 ++ > > > drivers/iio/chemical/Makefile | 1 + > > > drivers/iio/chemical/sps30.c | 359 ++++++++++++++++++++++++++++++++++ > > > 3 files changed, 371 insertions(+) > > > create mode 100644 drivers/iio/chemical/sps30.c > > > > [] > > > > > +#define pr_fmt(fmt) "sps30: " fmt > > > > I don't see its usage ? > > > > Hint: checkout how dev_err() is defined. > > > > +#include <linux/crc8.h> > > > +#include <linux/delay.h> > > > +#include <linux/i2c.h> > > > +#include <linux/iio/buffer.h> > > > +#include <linux/iio/iio.h> > > > +#include <linux/iio/sysfs.h> > > > +#include <linux/iio/trigger_consumer.h> > > > +#include <linux/iio/triggered_buffer.h> > > > +#include <linux/module.h> > > > + > > > +#define SPS30_CRC8_POLYNOMIAL 0x31 > > > + > > > +/* SPS30 commands */ > > > +#define SPS30_START_MEAS 0x0010 > > > +#define SPS30_STOP_MEAS 0x0104 > > > +#define SPS30_RESET 0xd304 > > > +#define SPS30_READ_DATA_READY_FLAG 0x0202 > > > +#define SPS30_READ_DATA 0x0300 > > > +#define SPS30_READ_SERIAL 0xD033 > > > > Could you please put a tab and align these macros. > > > > #define SPS30_START_MEAS 0x0010 > > #define SPS30_STOP_MEAS 0x0104 > > > > In my opinion this sort of alignment does not pay off in the long run. > Adding a new definition, a slightly longer one perhaps, can easily break > formatting. > > So I would stay with current one. Personally I agree with you on this one. I don't care enough to say either way though normally! > > > > > > +static int sps30_write_then_read(struct sps30_state *state, u8 *buf, > > > + int buf_size, u8 *data, int data_size) > > > +{ > > > + /* every two received data bytes are checksummed */ > > > + u8 tmp[data_size + data_size / 2]; > > > > No VLAs! > > > > https://lore.kernel.org/lkml/CA+55aFzCG-zNmZwX4A2FQpadafLfEzK6CC=qPXydAacU1RqZWA@mail.gmail.com/ > > > > Looks like -Wvla is some fairly recent addition to KBUILD_CFLAGS. Yeah, that was only after a 'lot' of effort over years to get the number present down to a small number. I wrote plenty of them in the early days of IIO so got a lot of those patches as part of the move to introducing the warning :) Jonathan ...
From: Andreas Brauchli <a.brauchli@elementarea.net> On Sat, 1 Dec 2018 15:58:57 +0000, Jonathan Cameron wrote: > On Sun, 25 Nov 2018 20:05:09 +0100 > Tomasz Duszynski <tduszyns@gmail.com> wrote: > > > On Sun, Nov 25, 2018 at 08:56:59AM +0000, Jonathan Cameron wrote: > > > On Sat, 24 Nov 2018 23:14:14 +0100 > > > Tomasz Duszynski <tduszyns@gmail.com> wrote: > > > > > > > Add support for Sensirion SPS30 particulate matter sensor. Thanks a lot for your work! A few comments inline, I'm also happy to assist with further clarifications. Since I work for Sensirion, feel free to add me on the Acked-by list. (The company server molests emails..) Acked-by: Andreas Brauchli <andreas.brauchli@sensirion.com> > > > > > > > > Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> > > > A few things inline. > > > > > > I'm particularly curious as to why we are ignoring two of the particle > > > sizes that the sensor seems to capture? > > > > > > > I was thinking about adding first the most common ones i.e PM2.5 and > > PM10 and the rest of them later on if there's a particular need. > > > > On the other hand I can add PM1.0 and PM4.0 now so that we have > > everything in place once new dust sensors appear on the market. > > I would. I do hope there don't turn out to be 100s of different > views of what these values should be though. The various standards > should prevent that even if people tuck in one or two extra > just because they could. PM1.0 is definitely used in other sensors (e.g. Plantower), but on a quick search I couldn't find another PM4.0 one. Our rationale for the value is that, according to medical studies, anything below PM4.0 can affect the lungs. > > > > > It's seems reasonable to assume they will measure the very same > > subset of particulates. > > > > > Also, a 'potential' race in remove that I'd like us to make > > > 'obviously' correct rather than requiring hard thought on whether > > > it would be a problem. > > > > > > Thanks, > > > > > > Jonathan > > > > > > > --- > > > > drivers/iio/chemical/Kconfig | 11 ++ > > > > drivers/iio/chemical/Makefile | 1 + > > > > drivers/iio/chemical/sps30.c | 359 ++++++++++++++++++++++++++++++++++ > > > > 3 files changed, 371 insertions(+) > > > > create mode 100644 drivers/iio/chemical/sps30.c > > > > > > > > diff --git a/drivers/iio/chemical/Kconfig b/drivers/iio/chemical/Kconfig > > > > index b8e005be4f87..40057ecf8130 100644 > > > > --- a/drivers/iio/chemical/Kconfig > > > > +++ b/drivers/iio/chemical/Kconfig > > > > @@ -61,6 +61,17 @@ config IAQCORE > > > > iAQ-Core Continuous/Pulsed VOC (Volatile Organic Compounds) > > > > sensors > > > > > > > > +config SPS30 > > > > + tristate "SPS30 Particulate Matter sensor" > > > > + depends on I2C > > > > + select CRC8 > > > > + help > > > > + Say Y here to build support for the Sensirion SPS30 Particulate > > > > + Matter sensor. > > > > + > > > > + To compile this driver as a module, choose M here: the module will > > > > + be called sps30. > > > > + > > > > config VZ89X > > > > tristate "SGX Sensortech MiCS VZ89X VOC sensor" > > > > depends on I2C > > > > diff --git a/drivers/iio/chemical/Makefile b/drivers/iio/chemical/Makefile > > > > index 2f4c4ba4d781..9f42f4252151 100644 > > > > --- a/drivers/iio/chemical/Makefile > > > > +++ b/drivers/iio/chemical/Makefile > > > > @@ -9,4 +9,5 @@ obj-$(CONFIG_BME680_I2C) += bme680_i2c.o > > > > obj-$(CONFIG_BME680_SPI) += bme680_spi.o > > > > obj-$(CONFIG_CCS811) += ccs811.o > > > > obj-$(CONFIG_IAQCORE) += ams-iaq-core.o > > > > +obj-$(CONFIG_SPS30) += sps30.o > > > > obj-$(CONFIG_VZ89X) += vz89x.o > > > > diff --git a/drivers/iio/chemical/sps30.c b/drivers/iio/chemical/sps30.c > > > > new file mode 100644 > > > > index 000000000000..bf802621ae7f > > > > --- /dev/null > > > > +++ b/drivers/iio/chemical/sps30.c > > > > @@ -0,0 +1,359 @@ > > > > +// SPDX-License-Identifier: GPL-2.0 > > > > +/* > > > > + * Sensirion SPS30 Particulate Matter sensor driver > > > > + * > > > > + * Copyright (c) Tomasz Duszynski <tduszyns@gmail.com> > > > > + * > > > > + * I2C slave address: 0x69 > > > > + * > > > > + * TODO: > > > > + * - support for turning on fan cleaning > > > > + * - support for reading/setting auto cleaning interval > > > > + */ > > > > + > > > > +#define pr_fmt(fmt) "sps30: " fmt > > > > + > > > > +#include <linux/crc8.h> > > > > +#include <linux/delay.h> > > > > +#include <linux/i2c.h> > > > > +#include <linux/iio/buffer.h> > > > > +#include <linux/iio/iio.h> > > > > +#include <linux/iio/sysfs.h> > > > > +#include <linux/iio/trigger_consumer.h> > > > > +#include <linux/iio/triggered_buffer.h> > > > > +#include <linux/module.h> > > > > + > > > > +#define SPS30_CRC8_POLYNOMIAL 0x31 > > > > + > > > > +/* SPS30 commands */ > > > > +#define SPS30_START_MEAS 0x0010 > > > > +#define SPS30_STOP_MEAS 0x0104 > > > > +#define SPS30_RESET 0xd304 lower case d vs upper case in SPS30_READ_SERIAL > > > > +#define SPS30_READ_DATA_READY_FLAG 0x0202 > > > > +#define SPS30_READ_DATA 0x0300 > > > > +#define SPS30_READ_SERIAL 0xD033 > > > > + > > > > +#define SPS30_CHAN(_index, _mod) { \ > > > > + .type = IIO_MASSCONCENTRATION, \ > > > > + .modified = 1, \ > > > > + .channel2 = IIO_MOD_ ## _mod, \ > > > > + .info_mask_separate = BIT(IIO_CHAN_INFO_PROCESSED), \ > > > > + .scan_index = _index, \ > > > > + .scan_type = { \ > > > > + .sign = 'u', \ > > > > + .realbits = 12, \ > > > > + .storagebits = 32, \ > > > > > > That is unusual. Why do we need 32 bits to store a 12 bit value? > > > 16 should be plenty. It'll make a difference to the buffer > > > sizes if people just want to stream data and don't care about > > > timestamps as it'll halve the memory usage. > > > > Right, I could have picked up a petter values. But I've got at least one > > valid reason for doing that. Sensor datasheet specifies 0-1000 > > measurement range but simple tests showed that SPS30 can measure way beyond > > that. Interestingly, measurements are consistent with third party sensors. > > I'm guessing there are certification bodies for this sort of thing. They > may only have paid for the low end to be certified (or there may be no > official test for higher levels?) > > > > > So having 12/32 bit setting, especially 32 storagebits protects against > > future changes in datasheet (which is btw preliminary) i.e updating > > measurement range. The final datasheet is expected in Q1 2019. You could add the following link which always points to the latest version: https://www.sensirion.com/file/datasheet_sps30 > > Not really because userspace is going to assume the value is 12 bits and > will probably mask it as such, thus any change requires userspace to cope > with it. Once you are doing that, might as well just change the padding > as well. > > > > > But, I guess that 16 for real and storage bits should be more > > that enough. > > Feels like it to me as well. > > > > > > > > > Also, convention has always been to got for next 8,16,32,64 above > > > the realbits if there isn't a reason not to (shifting etc) > > > > > > How did we end up with 12 bits off the floating point conversion > > > anyway? Needs some docs. > > > > Matter of simple tests. I was able to trigger measurements of over > > 3000 ug/m3. > > Hmm. So potentially it will give readings with more? If so we should > work out a hard justification for that limit. Userspace will mask > against it (as the rest of the bits may be garbage - we don't force > them to 0 in other drivers and they often contain meta data if > not actual garbage). The SPS30 can output high values (e.g. 60,000), but the measurement principle only applies up to somewhere between 3000-5000 ug/m3. Anything above 3000 is highly imprecise. > > > > > > > > > > > > > + .endianness = IIO_CPU, \ > > > > + }, \ > > > > +} > > > > + > > > > +enum { > > > > + PM1p0, /* just a placeholder */ > > > > + PM2p5, > > > > + PM4p0, /* just a placeholder */ > > > > + PM10, > > > > +}; > > > > + > > > > +struct sps30_state { > > > > + struct i2c_client *client; > > > > + /* guards against concurrent access to sensor registers */ > > > > + struct mutex lock; > > > > +}; > > > > + > > > > +DECLARE_CRC8_TABLE(sps30_crc8_table); > > > > + > > > > > > I think you are fine locking wise, but it would be good to add a note > > > on what locks are expected to be held on entering this function. > > > > > > Without locks it's obviously very racey! > > > > > > > Understood. > > > > > > +static int sps30_write_then_read(struct sps30_state *state, u8 *buf, > > > > + int buf_size, u8 *data, int data_size) > > > > +{ > > > > + /* every two received data bytes are checksummed */ > > > > + u8 tmp[data_size + data_size / 2]; > > > > + int ret, i; > > > > + > > > > + /* > > > > + * Sensor does not support repeated start so instead of > > > > + * sending two i2c messages in a row we just send one by one. > > > > + */ > > > > + ret = i2c_master_send(state->client, buf, buf_size); > > > > + if (ret != buf_size) > > > > + return ret < 0 ? ret : -EIO; > > > > + > > > > + if (!data) > > > > + return 0; > > > > + > > > > + ret = i2c_master_recv(state->client, tmp, sizeof(tmp)); > > > > + if (ret != sizeof(tmp)) > > > > + return ret < 0 ? ret : -EIO; > > > > + > > > > + for (i = 0; i < sizeof(tmp); i += 3) { > > > > + u8 crc = crc8(sps30_crc8_table, &tmp[i], 2, CRC8_INIT_VALUE); > > > > + > > > > + if (crc != tmp[i + 2]) { > > > > + dev_err(&state->client->dev, > > > > + "data integrity check failed\n"); > > > > + return -EIO; > > > > + } > > > > + > > > > + *data++ = tmp[i]; > > > > + *data++ = tmp[i + 1]; > > > > + } > > > > + > > > > + return 0; > > > > +} > > > > + > > > > +static int sps30_do_cmd(struct sps30_state *state, u16 cmd, u8 *data, int size) > > > > +{ > > > > + /* depending on the command up to 3 bytes may be needed for argument */ > > > > + u8 buf[sizeof(cmd) + 3] = { cmd >> 8, cmd }; > > > > + > > > > + switch (cmd) { > > > > + case SPS30_START_MEAS: > > > > + buf[2] = 0x03; > > > > + buf[3] = 0x00; > > > > + buf[4] = 0xac; /* precomputed crc */ > > > > > > Could you put that in code and let the compiler do the pre compute? > > > Might be a little more elegant. > > > > > > > Okay. > > > > > > + return sps30_write_then_read(state, buf, 5, NULL, 0); > > > > + case SPS30_STOP_MEAS: > > > > + case SPS30_RESET: > > > > + return sps30_write_then_read(state, buf, 2, NULL, 0); > > > > + case SPS30_READ_DATA_READY_FLAG: > > > > + case SPS30_READ_DATA: > > > > + case SPS30_READ_SERIAL: > > > > + return sps30_write_then_read(state, buf, 2, data, size); > > > > + default: > > > > + return -EINVAL; > > > > + }; > > > > +} > > > > + > > > > +static int sps30_ieee754_to_int(const u8 *data) > > > > +{ > > > > + u32 val = ((u32)data[0] << 24) | ((u32)data[1] << 16) | > > > > + ((u32)data[2] << 8) | (u32)data[3], > > > Have a separate > > > u32 mantissa = (val << 9) >> 9 line. > > > What is this next line actually doing? Kind of looks like > > > a mask? If so just mask it with & as more readable. > > > > > > > Do you mean mantissa? We want to get rid of sign bit and 8 exponent bits. > Got it, but the above is the same as. > > val & 0x7ffffff; I think... Shifting like this immediately made me > think you were manually sign extending (but it's unsigned so obviously not). > > It's a mask to extract just the mantissa, so code it as one. > > > > > > > > + mantissa = (val << 9) >> 9; > > > > + int exp = (val >> 23) - 127; > > > > + > > > > + if (!exp && !mantissa) > > > > + return 0; > > > > + > > > > + if (exp < 0) > > > > + return 0; > > > > + > > > > + return (1 << exp) + (mantissa >> (23 - exp)); > > > > +} > > > > + > > > > +static int sps30_do_meas(struct sps30_state *state, int *pm2p5, int *pm10) > > > > +{ > > > > + /* > > > > + * Internally sensor stores measurements in a following manner: > > > > + * > > > > + * PM1p0: upper two bytes, crc8, lower two bytes, crc8 > > > > > > So there are other particle sizes that this sensor reads? Why > > > are we mapping them down to just the two channel types? > > > > > > > As said before, introducing PM1.0 and PM4.0 readings seems > > a reasonable option. > > Go for it. Userspace who doesn't care won't read them. > > > > > > > + * PM2p5: upper two bytes, crc8, lower two bytes, crc8 > > > > + * PM4p0: upper two bytes, crc8, lower two bytes, crc8 > > > > + * PM10: upper two bytes, crc8, lower two bytes, crc8 > > > > + * > > > > + * What follows next are number concentration measurements and > > > > + * typical particle size measurement. > > > > + * > > > > + * Once data is read from sensor crc bytes are stripped off > > > > + * hence we need 16 bytes of buffer space. > > > > + */ > > > > + int ret, tries = 5; > > > > + u8 buf[16]; > > > > + > > > > + while (tries--) { > > > > + ret = sps30_do_cmd(state, SPS30_READ_DATA_READY_FLAG, buf, 2); > > > > + if (ret) > > > > + return -EIO; > > > > + > > > > + /* new measurements ready to be read */ > > > > + if (buf[1] == 1) > > > > + break; > > > > + > > > > + usleep_range(300000, 400000); > > > > + } > > > > + > > > > + if (!tries) > > > > + return -ETIMEDOUT; > > > > + > > > > + ret = sps30_do_cmd(state, SPS30_READ_DATA, buf, sizeof(buf)); > > > > + if (ret) > > > > + return ret; > > > > + > > > > + /* > > > > + * All measurements come in IEEE754 single precision floating point > > > > + * format but sensor itself is not precise enough (-+ 10% error) > > > > + * to take full advantage of it. Hence converting result to int > > > > + * to keep things simple. > > > > > > Interesting. We have talked about allowing floating point formats for > > > sensors the provide them. Would that be beneficial here? > > > > > > > I recall this was discussed once but unfortunately do not > > remember final conclusion. Anyway, in case of this device datasheet > > states that readings have maximum error of -+10% in given range which > > makes me think that using floats here is an overkill. > > > > Example, reading of 1000.123412ug/m3 has error of -+100ug/m3. > > Does it really matter if care about fractional part? The datasheet specifies absolute precision, the relative precision is much better. The noise level is at ca. 1%. We thus suggest using 16bit values with 2bits dedicated to fixed point decimals. > > *laughs*. It does make you wonder why they ended up as floating point > unless it is sensitive at very low levels? Note I know nothing about > particle sensing at all! > ..used internally > > > > Just out of curiosity, if IIO gets support for floats would it > > be problematic to to add extra channel returning measurements in floats? > > Or it rather will not fly.. > > It's hard for userspace to interpret the case of two channels measuring the > same thing. So it could be done (and we have once or twice done this) > but it's messy. > > > > > > > + */ > > > > + *pm2p5 = sps30_ieee754_to_int(&buf[PM2p5 * 4]); > > > > + *pm10 = sps30_ieee754_to_int(&buf[PM10 * 4]); > > > > + > > > > + return 0; > > > > +} > > > > + > > > > +static irqreturn_t sps30_trigger_handler(int irq, void *p) > > > > +{ > > > > + struct iio_poll_func *pf = p; > > > > + struct iio_dev *indio_dev = pf->indio_dev; > > > > + struct sps30_state *state = iio_priv(indio_dev); > > > > + u32 buf[4]; /* PM2p5, PM10, timestamp */ > > > > + int ret; > > > > + > > > > + mutex_lock(&state->lock); > > > > + ret = sps30_do_meas(state, &buf[0], &buf[1]); > > > > + mutex_unlock(&state->lock); > > > > + if (ret < 0) > > > > + goto err; > > > > + > > > > + iio_push_to_buffers_with_timestamp(indio_dev, buf, > > > > + iio_get_time_ns(indio_dev)); > > > > +err: > > > > + iio_trigger_notify_done(indio_dev->trig); > > > > + > > > > + return IRQ_HANDLED; > > > > +} > > > > + > > > > +static int sps30_read_raw(struct iio_dev *indio_dev, > > > > + struct iio_chan_spec const *chan, > > > > + int *val, int *val2, long mask) > > > > +{ > > > > + struct sps30_state *state = iio_priv(indio_dev); > > > > + int ret; > > > > + > > > > + switch (mask) { > > > > + case IIO_CHAN_INFO_PROCESSED: > > > > + switch (chan->type) { > > > > + case IIO_MASSCONCENTRATION: > > > > + mutex_lock(&state->lock); > > > > + switch (chan->channel2) { > > > > + case IIO_MOD_PM2p5: > > > > + ret = sps30_do_meas(state, val, val2); > > > > + break; > > > > + case IIO_MOD_PM10: > > > > + ret = sps30_do_meas(state, val2, val); > > > > + break; > > > > + default: > > > > + break; > > > > + } > > > > + mutex_unlock(&state->lock); > > > > + if (ret) > > > > + return ret; > > > > + > > > > + return IIO_VAL_INT; > > > > + default: > > > > + return -EINVAL; > > > > + } > > > > + break; > > > > + default: > > > You can't get here. Is this a warning suppression? > > > If so just add a comment saying so to prevent it being removed > > > by someone else later. > > > > > > > Okay. > > > > > > + return -EINVAL; > > > > + } > > > > +} > > > > + > > > > +static const struct iio_info sps30_info = { > > > > + .read_raw = sps30_read_raw, > > > > +}; > > > > + > > > From a readability point of view, it would be helpful to pull > > > the macro SPS30_CHAN down here in the code so we don't > > > need to go jumping around to check what it is doing. > > > > > > > Okay. > > > > > > +static const struct iio_chan_spec sps30_channels[] = { > > > > + SPS30_CHAN(0, PM2p5), > > > > + SPS30_CHAN(1, PM10), > > > > + IIO_CHAN_SOFT_TIMESTAMP(2), > > > > +}; > > > > + > > > > +static const unsigned long sps30_scan_masks[] = { 0x03, 0x00 }; > > > > + > > > > +static int sps30_probe(struct i2c_client *client) > > > > +{ > > > > + struct iio_dev *indio_dev; > > > > + struct sps30_state *state; > > > > + u8 buf[32] = { }; > > > > + int ret; > > > > + > > > > + if (!i2c_check_functionality(client->adapter, I2C_FUNC_I2C)) > > > > + return -EOPNOTSUPP; > > > > + > > > > + indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*state)); > > > > + if (!indio_dev) > > > > + return -ENOMEM; > > > > + > > > > + state = iio_priv(indio_dev); > > > > + i2c_set_clientdata(client, indio_dev); > > > > + state->client = client; > > > > + indio_dev->dev.parent = &client->dev; > > > > + indio_dev->info = &sps30_info; > > > > + indio_dev->name = client->name; > > > > + indio_dev->channels = sps30_channels; > > > > + indio_dev->num_channels = ARRAY_SIZE(sps30_channels); > > > > + indio_dev->modes = INDIO_DIRECT_MODE; > > > > + indio_dev->available_scan_masks = sps30_scan_masks; > > > > + > > > > + mutex_init(&state->lock); > > > > + crc8_populate_msb(sps30_crc8_table, SPS30_CRC8_POLYNOMIAL); > > > > + > > > > + /* > > > > + * Power-on-reset causes sensor to produce some glitch on i2c bus > > > > + * and some controllers end up in error state. Recover simply > > > > + * by placing something on the bus. > > > > + */ Apologies for that. I talked to the firmware engineer and we'll do our best to have it fixed in the next update scheduled for Q1 2019. The cause seems to be the pin initialization causing the clock to be pulled down for ca. 2.5us. > > > > + ret = sps30_do_cmd(state, SPS30_RESET, NULL, 0); > > > > + if (ret) { > > > > + dev_err(&client->dev, "failed to reset device\n"); > > > > + return ret; > > > > + } > > > > + usleep_range(2500000, 3500000); > > > > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > > > > > > Talk me through this logic. We stop it then pretty much immediately > > > start it again? Needs a comment. > > > > > > > The idea is to send some message after resetting sensor so that > > i2c controller recovers from error state. I decided to send STOP_MEAS > > as it's a NOP in this case. I'll try to do more testing with other > > SPS30s and perhaps different boards. > > Ah. Makes sense. Just add a comment to the code saying this and it's > fine. Not to shift the blame, but the recovery is likely controller specific and might be better handled at that level. Consider the case where the faulty device is present but the driver is not loaded after the initialization.. > > > > > > > + > > > > + ret = sps30_do_cmd(state, SPS30_READ_SERIAL, buf, sizeof(buf)); > > > > + if (ret) { > > > > + dev_err(&client->dev, "failed to read serial number\n"); > > > > + return ret; > > > > + } > > > > + dev_info(&client->dev, "serial number: %s\n", buf); > > > > + > > > > + ret = sps30_do_cmd(state, SPS30_START_MEAS, NULL, 0); > > > > + if (ret) { > > > > > > This is not unwound on error. See comment on remove race below. > > > > > > > + dev_err(&client->dev, "failed to start measurement\n"); > > > > + return ret; > > > > + } > > > > + > > > > + ret = devm_iio_triggered_buffer_setup(&client->dev, indio_dev, NULL, > > > > + sps30_trigger_handler, NULL); > > > > + if (ret) > > > > + return ret; > > > > + > > > > + return devm_iio_device_register(&client->dev, indio_dev); > > > > +} > > > > + > > > > +static int sps30_remove(struct i2c_client *client) > > > > +{ > > > > + struct iio_dev *indio_dev = i2c_get_clientdata(client); > > > > + struct sps30_state *state = iio_priv(indio_dev); > > > > + > > > > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > > > This looks like a race to me. > > > > > > > Right, this needs fixing. > > > > > You turn off the measurements before removing the interface to them. > > > It's certainly not in the 'obviously' right category. > > > > > > As such I would either use a devm action to do this stop, > > > or not use the managed interfaces for everything in probe > > > after the equivalent start. > > > The devm_add_action_or_reset would be the cleanest option I think.. > > > Will also fix the cleanup on error in probe. > > > > > > > + > > > > + return 0; > > > > +} > > > > + > > > > +static const struct i2c_device_id sps30_id[] = { > > > > + { "sps30" }, > > > > + { } > > > > +}; > > > > +MODULE_DEVICE_TABLE(i2c, sps30_id); > > > > + > > > > +static const struct of_device_id sps30_of_match[] = { > > > > + { .compatible = "sensirion,sps30" }, > > > > + { } > > > > +}; > > > > +MODULE_DEVICE_TABLE(of, sps30_of_match); > > > > + > > > > +static struct i2c_driver sps30_driver = { > > > > + .driver = { > > > > + .name = "sps30", > > > > + .of_match_table = sps30_of_match, > > > > + }, > > > > + .id_table = sps30_id, > > > > + .probe_new = sps30_probe, > > > > + .remove = sps30_remove, > > > > +}; > > > > +module_i2c_driver(sps30_driver); > > > > + > > > > +MODULE_AUTHOR("Tomasz Duszynski <tduszyns@gmail.com>"); > > > > +MODULE_DESCRIPTION("Sensirion SPS30 particulate matter sensor driver"); > > > > +MODULE_LICENSE("GPL v2"); > > >
On Mon, Dec 03, 2018 at 11:30:45AM +0100, Andreas Brauchli wrote: > From: Andreas Brauchli <a.brauchli@elementarea.net> > > On Sat, 1 Dec 2018 15:58:57 +0000, Jonathan Cameron wrote: > > On Sun, 25 Nov 2018 20:05:09 +0100 > > Tomasz Duszynski <tduszyns@gmail.com> wrote: > > > > > On Sun, Nov 25, 2018 at 08:56:59AM +0000, Jonathan Cameron wrote: > > > > On Sat, 24 Nov 2018 23:14:14 +0100 > > > > Tomasz Duszynski <tduszyns@gmail.com> wrote: > > > > > > > > > Add support for Sensirion SPS30 particulate matter sensor. > > Thanks a lot for your work! A few comments inline, I'm also happy to assist with > further clarifications. > > Since I work for Sensirion, feel free to add me on the Acked-by list. (The > company server molests emails..) > > Acked-by: Andreas Brauchli <andreas.brauchli@sensirion.com> > > > > > > > > > > > Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> > > > > A few things inline. > > > > > > > > I'm particularly curious as to why we are ignoring two of the particle > > > > sizes that the sensor seems to capture? > > > > > > > > > > I was thinking about adding first the most common ones i.e PM2.5 and > > > PM10 and the rest of them later on if there's a particular need. > > > > > > On the other hand I can add PM1.0 and PM4.0 now so that we have > > > everything in place once new dust sensors appear on the market. > > > > I would. I do hope there don't turn out to be 100s of different > > views of what these values should be though. The various standards > > should prevent that even if people tuck in one or two extra > > just because they could. > > PM1.0 is definitely used in other sensors (e.g. Plantower), but on a quick > search I couldn't find another PM4.0 one. > > Our rationale for the value is that, according to medical studies, anything > below PM4.0 can affect the lungs. > Fair enough. > > > > > > > > It's seems reasonable to assume they will measure the very same > > > subset of particulates. > > > > > > > Also, a 'potential' race in remove that I'd like us to make > > > > 'obviously' correct rather than requiring hard thought on whether > > > > it would be a problem. > > > > > > > > Thanks, > > > > > > > > Jonathan > > > > > > > > > --- > > > > > drivers/iio/chemical/Kconfig | 11 ++ > > > > > drivers/iio/chemical/Makefile | 1 + > > > > > drivers/iio/chemical/sps30.c | 359 ++++++++++++++++++++++++++++++++++ > > > > > 3 files changed, 371 insertions(+) > > > > > create mode 100644 drivers/iio/chemical/sps30.c > > > > > > > > > > diff --git a/drivers/iio/chemical/Kconfig b/drivers/iio/chemical/Kconfig > > > > > index b8e005be4f87..40057ecf8130 100644 > > > > > --- a/drivers/iio/chemical/Kconfig > > > > > +++ b/drivers/iio/chemical/Kconfig > > > > > @@ -61,6 +61,17 @@ config IAQCORE > > > > > iAQ-Core Continuous/Pulsed VOC (Volatile Organic Compounds) > > > > > sensors > > > > > > > > > > +config SPS30 > > > > > + tristate "SPS30 Particulate Matter sensor" > > > > > + depends on I2C > > > > > + select CRC8 > > > > > + help > > > > > + Say Y here to build support for the Sensirion SPS30 Particulate > > > > > + Matter sensor. > > > > > + > > > > > + To compile this driver as a module, choose M here: the module will > > > > > + be called sps30. > > > > > + > > > > > config VZ89X > > > > > tristate "SGX Sensortech MiCS VZ89X VOC sensor" > > > > > depends on I2C > > > > > diff --git a/drivers/iio/chemical/Makefile b/drivers/iio/chemical/Makefile > > > > > index 2f4c4ba4d781..9f42f4252151 100644 > > > > > --- a/drivers/iio/chemical/Makefile > > > > > +++ b/drivers/iio/chemical/Makefile > > > > > @@ -9,4 +9,5 @@ obj-$(CONFIG_BME680_I2C) += bme680_i2c.o > > > > > obj-$(CONFIG_BME680_SPI) += bme680_spi.o > > > > > obj-$(CONFIG_CCS811) += ccs811.o > > > > > obj-$(CONFIG_IAQCORE) += ams-iaq-core.o > > > > > +obj-$(CONFIG_SPS30) += sps30.o > > > > > obj-$(CONFIG_VZ89X) += vz89x.o > > > > > diff --git a/drivers/iio/chemical/sps30.c b/drivers/iio/chemical/sps30.c > > > > > new file mode 100644 > > > > > index 000000000000..bf802621ae7f > > > > > --- /dev/null > > > > > +++ b/drivers/iio/chemical/sps30.c > > > > > @@ -0,0 +1,359 @@ > > > > > +// SPDX-License-Identifier: GPL-2.0 > > > > > +/* > > > > > + * Sensirion SPS30 Particulate Matter sensor driver > > > > > + * > > > > > + * Copyright (c) Tomasz Duszynski <tduszyns@gmail.com> > > > > > + * > > > > > + * I2C slave address: 0x69 > > > > > + * > > > > > + * TODO: > > > > > + * - support for turning on fan cleaning > > > > > + * - support for reading/setting auto cleaning interval > > > > > + */ > > > > > + > > > > > +#define pr_fmt(fmt) "sps30: " fmt > > > > > + > > > > > +#include <linux/crc8.h> > > > > > +#include <linux/delay.h> > > > > > +#include <linux/i2c.h> > > > > > +#include <linux/iio/buffer.h> > > > > > +#include <linux/iio/iio.h> > > > > > +#include <linux/iio/sysfs.h> > > > > > +#include <linux/iio/trigger_consumer.h> > > > > > +#include <linux/iio/triggered_buffer.h> > > > > > +#include <linux/module.h> > > > > > + > > > > > +#define SPS30_CRC8_POLYNOMIAL 0x31 > > > > > + > > > > > +/* SPS30 commands */ > > > > > +#define SPS30_START_MEAS 0x0010 > > > > > +#define SPS30_STOP_MEAS 0x0104 > > > > > +#define SPS30_RESET 0xd304 > > lower case d vs upper case in SPS30_READ_SERIAL > Good catch. > > > > > +#define SPS30_READ_DATA_READY_FLAG 0x0202 > > > > > +#define SPS30_READ_DATA 0x0300 > > > > > +#define SPS30_READ_SERIAL 0xD033 > > > > > + > > > > > +#define SPS30_CHAN(_index, _mod) { \ > > > > > + .type = IIO_MASSCONCENTRATION, \ > > > > > + .modified = 1, \ > > > > > + .channel2 = IIO_MOD_ ## _mod, \ > > > > > + .info_mask_separate = BIT(IIO_CHAN_INFO_PROCESSED), \ > > > > > + .scan_index = _index, \ > > > > > + .scan_type = { \ > > > > > + .sign = 'u', \ > > > > > + .realbits = 12, \ > > > > > + .storagebits = 32, \ > > > > > > > > That is unusual. Why do we need 32 bits to store a 12 bit value? > > > > 16 should be plenty. It'll make a difference to the buffer > > > > sizes if people just want to stream data and don't care about > > > > timestamps as it'll halve the memory usage. > > > > > > Right, I could have picked up a petter values. But I've got at least one > > > valid reason for doing that. Sensor datasheet specifies 0-1000 > > > measurement range but simple tests showed that SPS30 can measure way beyond > > > that. Interestingly, measurements are consistent with third party sensors. > > > > I'm guessing there are certification bodies for this sort of thing. They > > may only have paid for the low end to be certified (or there may be no > > official test for higher levels?) > > > > > > > > So having 12/32 bit setting, especially 32 storagebits protects against > > > future changes in datasheet (which is btw preliminary) i.e updating > > > measurement range. > > The final datasheet is expected in Q1 2019. You could add the following link > which always points to the latest version: > > https://www.sensirion.com/file/datasheet_sps30 > Personally, I dislike the idea of adding datasheet links to the drivers. Rationale being that they become outdated pretty soon. Anyone interested in the details can find the doc pretty easily himself. > > > > Not really because userspace is going to assume the value is 12 bits and > > will probably mask it as such, thus any change requires userspace to cope > > with it. Once you are doing that, might as well just change the padding > > as well. > > > > > > > > But, I guess that 16 for real and storage bits should be more > > > that enough. > > > > Feels like it to me as well. > > > > > > > > > > > > > Also, convention has always been to got for next 8,16,32,64 above > > > > the realbits if there isn't a reason not to (shifting etc) > > > > > > > > How did we end up with 12 bits off the floating point conversion > > > > anyway? Needs some docs. > > > > > > Matter of simple tests. I was able to trigger measurements of over > > > 3000 ug/m3. > > > > Hmm. So potentially it will give readings with more? If so we should > > work out a hard justification for that limit. Userspace will mask > > against it (as the rest of the bits may be garbage - we don't force > > them to 0 in other drivers and they often contain meta data if > > not actual garbage). > > The SPS30 can output high values (e.g. 60,000), but the measurement principle > only applies up to somewhere between 3000-5000 ug/m3. Anything above 3000 is > highly imprecise. > In that case, clamping the measurements to 3000.00 would be fine I guess. > > > > > > > > > > > > > > > > > > + .endianness = IIO_CPU, \ > > > > > + }, \ > > > > > +} > > > > > + > > > > > +enum { > > > > > + PM1p0, /* just a placeholder */ > > > > > + PM2p5, > > > > > + PM4p0, /* just a placeholder */ > > > > > + PM10, > > > > > +}; > > > > > + > > > > > +struct sps30_state { > > > > > + struct i2c_client *client; > > > > > + /* guards against concurrent access to sensor registers */ > > > > > + struct mutex lock; > > > > > +}; > > > > > + > > > > > +DECLARE_CRC8_TABLE(sps30_crc8_table); > > > > > + > > > > > > > > I think you are fine locking wise, but it would be good to add a note > > > > on what locks are expected to be held on entering this function. > > > > > > > > Without locks it's obviously very racey! > > > > > > > > > > Understood. > > > > > > > > +static int sps30_write_then_read(struct sps30_state *state, u8 *buf, > > > > > + int buf_size, u8 *data, int data_size) > > > > > +{ > > > > > + /* every two received data bytes are checksummed */ > > > > > + u8 tmp[data_size + data_size / 2]; > > > > > + int ret, i; > > > > > + > > > > > + /* > > > > > + * Sensor does not support repeated start so instead of > > > > > + * sending two i2c messages in a row we just send one by one. > > > > > + */ > > > > > + ret = i2c_master_send(state->client, buf, buf_size); > > > > > + if (ret != buf_size) > > > > > + return ret < 0 ? ret : -EIO; > > > > > + > > > > > + if (!data) > > > > > + return 0; > > > > > + > > > > > + ret = i2c_master_recv(state->client, tmp, sizeof(tmp)); > > > > > + if (ret != sizeof(tmp)) > > > > > + return ret < 0 ? ret : -EIO; > > > > > + > > > > > + for (i = 0; i < sizeof(tmp); i += 3) { > > > > > + u8 crc = crc8(sps30_crc8_table, &tmp[i], 2, CRC8_INIT_VALUE); > > > > > + > > > > > + if (crc != tmp[i + 2]) { > > > > > + dev_err(&state->client->dev, > > > > > + "data integrity check failed\n"); > > > > > + return -EIO; > > > > > + } > > > > > + > > > > > + *data++ = tmp[i]; > > > > > + *data++ = tmp[i + 1]; > > > > > + } > > > > > + > > > > > + return 0; > > > > > +} > > > > > + > > > > > +static int sps30_do_cmd(struct sps30_state *state, u16 cmd, u8 *data, int size) > > > > > +{ > > > > > + /* depending on the command up to 3 bytes may be needed for argument */ > > > > > + u8 buf[sizeof(cmd) + 3] = { cmd >> 8, cmd }; > > > > > + > > > > > + switch (cmd) { > > > > > + case SPS30_START_MEAS: > > > > > + buf[2] = 0x03; > > > > > + buf[3] = 0x00; > > > > > + buf[4] = 0xac; /* precomputed crc */ > > > > > > > > Could you put that in code and let the compiler do the pre compute? > > > > Might be a little more elegant. > > > > > > > > > > Okay. > > > > > > > > + return sps30_write_then_read(state, buf, 5, NULL, 0); > > > > > + case SPS30_STOP_MEAS: > > > > > + case SPS30_RESET: > > > > > + return sps30_write_then_read(state, buf, 2, NULL, 0); > > > > > + case SPS30_READ_DATA_READY_FLAG: > > > > > + case SPS30_READ_DATA: > > > > > + case SPS30_READ_SERIAL: > > > > > + return sps30_write_then_read(state, buf, 2, data, size); > > > > > + default: > > > > > + return -EINVAL; > > > > > + }; > > > > > +} > > > > > + > > > > > +static int sps30_ieee754_to_int(const u8 *data) > > > > > +{ > > > > > + u32 val = ((u32)data[0] << 24) | ((u32)data[1] << 16) | > > > > > + ((u32)data[2] << 8) | (u32)data[3], > > > > Have a separate > > > > u32 mantissa = (val << 9) >> 9 line. > > > > What is this next line actually doing? Kind of looks like > > > > a mask? If so just mask it with & as more readable. > > > > > > > > > > Do you mean mantissa? We want to get rid of sign bit and 8 exponent bits. > > Got it, but the above is the same as. > > > > val & 0x7ffffff; I think... Shifting like this immediately made me > > think you were manually sign extending (but it's unsigned so obviously not). > > > > It's a mask to extract just the mantissa, so code it as one. > > > > > > > > > > > > + mantissa = (val << 9) >> 9; > > > > > + int exp = (val >> 23) - 127; > > > > > + > > > > > + if (!exp && !mantissa) > > > > > + return 0; > > > > > + > > > > > + if (exp < 0) > > > > > + return 0; > > > > > + > > > > > + return (1 << exp) + (mantissa >> (23 - exp)); > > > > > +} > > > > > + > > > > > +static int sps30_do_meas(struct sps30_state *state, int *pm2p5, int *pm10) > > > > > +{ > > > > > + /* > > > > > + * Internally sensor stores measurements in a following manner: > > > > > + * > > > > > + * PM1p0: upper two bytes, crc8, lower two bytes, crc8 > > > > > > > > So there are other particle sizes that this sensor reads? Why > > > > are we mapping them down to just the two channel types? > > > > > > > > > > As said before, introducing PM1.0 and PM4.0 readings seems > > > a reasonable option. > > > > Go for it. Userspace who doesn't care won't read them. > > > > > > > > > > + * PM2p5: upper two bytes, crc8, lower two bytes, crc8 > > > > > + * PM4p0: upper two bytes, crc8, lower two bytes, crc8 > > > > > + * PM10: upper two bytes, crc8, lower two bytes, crc8 > > > > > + * > > > > > + * What follows next are number concentration measurements and > > > > > + * typical particle size measurement. > > > > > + * > > > > > + * Once data is read from sensor crc bytes are stripped off > > > > > + * hence we need 16 bytes of buffer space. > > > > > + */ > > > > > + int ret, tries = 5; > > > > > + u8 buf[16]; > > > > > + > > > > > + while (tries--) { > > > > > + ret = sps30_do_cmd(state, SPS30_READ_DATA_READY_FLAG, buf, 2); > > > > > + if (ret) > > > > > + return -EIO; > > > > > + > > > > > + /* new measurements ready to be read */ > > > > > + if (buf[1] == 1) > > > > > + break; > > > > > + > > > > > + usleep_range(300000, 400000); > > > > > + } > > > > > + > > > > > + if (!tries) > > > > > + return -ETIMEDOUT; > > > > > + > > > > > + ret = sps30_do_cmd(state, SPS30_READ_DATA, buf, sizeof(buf)); > > > > > + if (ret) > > > > > + return ret; > > > > > + > > > > > + /* > > > > > + * All measurements come in IEEE754 single precision floating point > > > > > + * format but sensor itself is not precise enough (-+ 10% error) > > > > > + * to take full advantage of it. Hence converting result to int > > > > > + * to keep things simple. > > > > > > > > Interesting. We have talked about allowing floating point formats for > > > > sensors the provide them. Would that be beneficial here? > > > > > > > > > > I recall this was discussed once but unfortunately do not > > > remember final conclusion. Anyway, in case of this device datasheet > > > states that readings have maximum error of -+10% in given range which > > > makes me think that using floats here is an overkill. > > > > > > Example, reading of 1000.123412ug/m3 has error of -+100ug/m3. > > > Does it really matter if care about fractional part? > > The datasheet specifies absolute precision, the relative precision is much > better. The noise level is at ca. 1%. We thus suggest using 16bit values with > 2bits dedicated to fixed point decimals. > Wondering why that was not mentioned in the datasheet in the first place but good to know anyway. Then I am fine with adding that extra level of precision i.e two extra decimal places. > > > > *laughs*. It does make you wonder why they ended up as floating point > > unless it is sensitive at very low levels? Note I know nothing about > > particle sensing at all! > > > > ..used internally > > > > > > > Just out of curiosity, if IIO gets support for floats would it > > > be problematic to to add extra channel returning measurements in floats? > > > Or it rather will not fly.. > > > > It's hard for userspace to interpret the case of two channels measuring the > > same thing. So it could be done (and we have once or twice done this) > > but it's messy. > > > > > > > > > > + */ > > > > > + *pm2p5 = sps30_ieee754_to_int(&buf[PM2p5 * 4]); > > > > > + *pm10 = sps30_ieee754_to_int(&buf[PM10 * 4]); > > > > > + > > > > > + return 0; > > > > > +} > > > > > + > > > > > +static irqreturn_t sps30_trigger_handler(int irq, void *p) > > > > > +{ > > > > > + struct iio_poll_func *pf = p; > > > > > + struct iio_dev *indio_dev = pf->indio_dev; > > > > > + struct sps30_state *state = iio_priv(indio_dev); > > > > > + u32 buf[4]; /* PM2p5, PM10, timestamp */ > > > > > + int ret; > > > > > + > > > > > + mutex_lock(&state->lock); > > > > > + ret = sps30_do_meas(state, &buf[0], &buf[1]); > > > > > + mutex_unlock(&state->lock); > > > > > + if (ret < 0) > > > > > + goto err; > > > > > + > > > > > + iio_push_to_buffers_with_timestamp(indio_dev, buf, > > > > > + iio_get_time_ns(indio_dev)); > > > > > +err: > > > > > + iio_trigger_notify_done(indio_dev->trig); > > > > > + > > > > > + return IRQ_HANDLED; > > > > > +} > > > > > + > > > > > +static int sps30_read_raw(struct iio_dev *indio_dev, > > > > > + struct iio_chan_spec const *chan, > > > > > + int *val, int *val2, long mask) > > > > > +{ > > > > > + struct sps30_state *state = iio_priv(indio_dev); > > > > > + int ret; > > > > > + > > > > > + switch (mask) { > > > > > + case IIO_CHAN_INFO_PROCESSED: > > > > > + switch (chan->type) { > > > > > + case IIO_MASSCONCENTRATION: > > > > > + mutex_lock(&state->lock); > > > > > + switch (chan->channel2) { > > > > > + case IIO_MOD_PM2p5: > > > > > + ret = sps30_do_meas(state, val, val2); > > > > > + break; > > > > > + case IIO_MOD_PM10: > > > > > + ret = sps30_do_meas(state, val2, val); > > > > > + break; > > > > > + default: > > > > > + break; > > > > > + } > > > > > + mutex_unlock(&state->lock); > > > > > + if (ret) > > > > > + return ret; > > > > > + > > > > > + return IIO_VAL_INT; > > > > > + default: > > > > > + return -EINVAL; > > > > > + } > > > > > + break; > > > > > + default: > > > > You can't get here. Is this a warning suppression? > > > > If so just add a comment saying so to prevent it being removed > > > > by someone else later. > > > > > > > > > > Okay. > > > > > > > > + return -EINVAL; > > > > > + } > > > > > +} > > > > > + > > > > > +static const struct iio_info sps30_info = { > > > > > + .read_raw = sps30_read_raw, > > > > > +}; > > > > > + > > > > From a readability point of view, it would be helpful to pull > > > > the macro SPS30_CHAN down here in the code so we don't > > > > need to go jumping around to check what it is doing. > > > > > > > > > > Okay. > > > > > > > > +static const struct iio_chan_spec sps30_channels[] = { > > > > > + SPS30_CHAN(0, PM2p5), > > > > > + SPS30_CHAN(1, PM10), > > > > > + IIO_CHAN_SOFT_TIMESTAMP(2), > > > > > +}; > > > > > + > > > > > +static const unsigned long sps30_scan_masks[] = { 0x03, 0x00 }; > > > > > + > > > > > +static int sps30_probe(struct i2c_client *client) > > > > > +{ > > > > > + struct iio_dev *indio_dev; > > > > > + struct sps30_state *state; > > > > > + u8 buf[32] = { }; > > > > > + int ret; > > > > > + > > > > > + if (!i2c_check_functionality(client->adapter, I2C_FUNC_I2C)) > > > > > + return -EOPNOTSUPP; > > > > > + > > > > > + indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*state)); > > > > > + if (!indio_dev) > > > > > + return -ENOMEM; > > > > > + > > > > > + state = iio_priv(indio_dev); > > > > > + i2c_set_clientdata(client, indio_dev); > > > > > + state->client = client; > > > > > + indio_dev->dev.parent = &client->dev; > > > > > + indio_dev->info = &sps30_info; > > > > > + indio_dev->name = client->name; > > > > > + indio_dev->channels = sps30_channels; > > > > > + indio_dev->num_channels = ARRAY_SIZE(sps30_channels); > > > > > + indio_dev->modes = INDIO_DIRECT_MODE; > > > > > + indio_dev->available_scan_masks = sps30_scan_masks; > > > > > + > > > > > + mutex_init(&state->lock); > > > > > + crc8_populate_msb(sps30_crc8_table, SPS30_CRC8_POLYNOMIAL); > > > > > + > > > > > + /* > > > > > + * Power-on-reset causes sensor to produce some glitch on i2c bus > > > > > + * and some controllers end up in error state. Recover simply > > > > > + * by placing something on the bus. > > > > > + */ > > Apologies for that. I talked to the firmware engineer and we'll do our best to > have it fixed in the next update scheduled for Q1 2019. The cause seems to be > the pin initialization causing the clock to be pulled down for ca. 2.5us. > From what I see SDA is pulled low as well for the same amount of time and interestingly in happens always in about ~10ms after reset. > > > > > + ret = sps30_do_cmd(state, SPS30_RESET, NULL, 0); > > > > > + if (ret) { > > > > > + dev_err(&client->dev, "failed to reset device\n"); > > > > > + return ret; > > > > > + } > > > > > + usleep_range(2500000, 3500000); > > > > > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > > > > > > > > Talk me through this logic. We stop it then pretty much immediately > > > > start it again? Needs a comment. > > > > > > > > > > The idea is to send some message after resetting sensor so that > > > i2c controller recovers from error state. I decided to send STOP_MEAS > > > as it's a NOP in this case. I'll try to do more testing with other > > > SPS30s and perhaps different boards. > > > > Ah. Makes sense. Just add a comment to the code saying this and it's > > fine. > > Not to shift the blame, but the recovery is likely controller specific and might > be better handled at that level. Consider the case where the faulty device is > present but the driver is not loaded after the initialization.. > > > > > > > > > > > + > > > > > + ret = sps30_do_cmd(state, SPS30_READ_SERIAL, buf, sizeof(buf)); > > > > > + if (ret) { > > > > > + dev_err(&client->dev, "failed to read serial number\n"); > > > > > + return ret; > > > > > + } > > > > > + dev_info(&client->dev, "serial number: %s\n", buf); > > > > > + > > > > > + ret = sps30_do_cmd(state, SPS30_START_MEAS, NULL, 0); > > > > > + if (ret) { > > > > > > > > This is not unwound on error. See comment on remove race below. > > > > > > > > > + dev_err(&client->dev, "failed to start measurement\n"); > > > > > + return ret; > > > > > + } > > > > > + > > > > > + ret = devm_iio_triggered_buffer_setup(&client->dev, indio_dev, NULL, > > > > > + sps30_trigger_handler, NULL); > > > > > + if (ret) > > > > > + return ret; > > > > > + > > > > > + return devm_iio_device_register(&client->dev, indio_dev); > > > > > +} > > > > > + > > > > > +static int sps30_remove(struct i2c_client *client) > > > > > +{ > > > > > + struct iio_dev *indio_dev = i2c_get_clientdata(client); > > > > > + struct sps30_state *state = iio_priv(indio_dev); > > > > > + > > > > > + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); > > > > This looks like a race to me. > > > > > > > > > > Right, this needs fixing. > > > > > > > You turn off the measurements before removing the interface to them. > > > > It's certainly not in the 'obviously' right category. > > > > > > > > As such I would either use a devm action to do this stop, > > > > or not use the managed interfaces for everything in probe > > > > after the equivalent start. > > > > The devm_add_action_or_reset would be the cleanest option I think.. > > > > Will also fix the cleanup on error in probe. > > > > > > > > > + > > > > > + return 0; > > > > > +} > > > > > + > > > > > +static const struct i2c_device_id sps30_id[] = { > > > > > + { "sps30" }, > > > > > + { } > > > > > +}; > > > > > +MODULE_DEVICE_TABLE(i2c, sps30_id); > > > > > + > > > > > +static const struct of_device_id sps30_of_match[] = { > > > > > + { .compatible = "sensirion,sps30" }, > > > > > + { } > > > > > +}; > > > > > +MODULE_DEVICE_TABLE(of, sps30_of_match); > > > > > + > > > > > +static struct i2c_driver sps30_driver = { > > > > > + .driver = { > > > > > + .name = "sps30", > > > > > + .of_match_table = sps30_of_match, > > > > > + }, > > > > > + .id_table = sps30_id, > > > > > + .probe_new = sps30_probe, > > > > > + .remove = sps30_remove, > > > > > +}; > > > > > +module_i2c_driver(sps30_driver); > > > > > + > > > > > +MODULE_AUTHOR("Tomasz Duszynski <tduszyns@gmail.com>"); > > > > > +MODULE_DESCRIPTION("Sensirion SPS30 particulate matter sensor driver"); > > > > > +MODULE_LICENSE("GPL v2"); > > > >
diff --git a/drivers/iio/chemical/Kconfig b/drivers/iio/chemical/Kconfig index b8e005be4f87..40057ecf8130 100644 --- a/drivers/iio/chemical/Kconfig +++ b/drivers/iio/chemical/Kconfig @@ -61,6 +61,17 @@ config IAQCORE iAQ-Core Continuous/Pulsed VOC (Volatile Organic Compounds) sensors +config SPS30 + tristate "SPS30 Particulate Matter sensor" + depends on I2C + select CRC8 + help + Say Y here to build support for the Sensirion SPS30 Particulate + Matter sensor. + + To compile this driver as a module, choose M here: the module will + be called sps30. + config VZ89X tristate "SGX Sensortech MiCS VZ89X VOC sensor" depends on I2C diff --git a/drivers/iio/chemical/Makefile b/drivers/iio/chemical/Makefile index 2f4c4ba4d781..9f42f4252151 100644 --- a/drivers/iio/chemical/Makefile +++ b/drivers/iio/chemical/Makefile @@ -9,4 +9,5 @@ obj-$(CONFIG_BME680_I2C) += bme680_i2c.o obj-$(CONFIG_BME680_SPI) += bme680_spi.o obj-$(CONFIG_CCS811) += ccs811.o obj-$(CONFIG_IAQCORE) += ams-iaq-core.o +obj-$(CONFIG_SPS30) += sps30.o obj-$(CONFIG_VZ89X) += vz89x.o diff --git a/drivers/iio/chemical/sps30.c b/drivers/iio/chemical/sps30.c new file mode 100644 index 000000000000..bf802621ae7f --- /dev/null +++ b/drivers/iio/chemical/sps30.c @@ -0,0 +1,359 @@ +// SPDX-License-Identifier: GPL-2.0 +/* + * Sensirion SPS30 Particulate Matter sensor driver + * + * Copyright (c) Tomasz Duszynski <tduszyns@gmail.com> + * + * I2C slave address: 0x69 + * + * TODO: + * - support for turning on fan cleaning + * - support for reading/setting auto cleaning interval + */ + +#define pr_fmt(fmt) "sps30: " fmt + +#include <linux/crc8.h> +#include <linux/delay.h> +#include <linux/i2c.h> +#include <linux/iio/buffer.h> +#include <linux/iio/iio.h> +#include <linux/iio/sysfs.h> +#include <linux/iio/trigger_consumer.h> +#include <linux/iio/triggered_buffer.h> +#include <linux/module.h> + +#define SPS30_CRC8_POLYNOMIAL 0x31 + +/* SPS30 commands */ +#define SPS30_START_MEAS 0x0010 +#define SPS30_STOP_MEAS 0x0104 +#define SPS30_RESET 0xd304 +#define SPS30_READ_DATA_READY_FLAG 0x0202 +#define SPS30_READ_DATA 0x0300 +#define SPS30_READ_SERIAL 0xD033 + +#define SPS30_CHAN(_index, _mod) { \ + .type = IIO_MASSCONCENTRATION, \ + .modified = 1, \ + .channel2 = IIO_MOD_ ## _mod, \ + .info_mask_separate = BIT(IIO_CHAN_INFO_PROCESSED), \ + .scan_index = _index, \ + .scan_type = { \ + .sign = 'u', \ + .realbits = 12, \ + .storagebits = 32, \ + .endianness = IIO_CPU, \ + }, \ +} + +enum { + PM1p0, /* just a placeholder */ + PM2p5, + PM4p0, /* just a placeholder */ + PM10, +}; + +struct sps30_state { + struct i2c_client *client; + /* guards against concurrent access to sensor registers */ + struct mutex lock; +}; + +DECLARE_CRC8_TABLE(sps30_crc8_table); + +static int sps30_write_then_read(struct sps30_state *state, u8 *buf, + int buf_size, u8 *data, int data_size) +{ + /* every two received data bytes are checksummed */ + u8 tmp[data_size + data_size / 2]; + int ret, i; + + /* + * Sensor does not support repeated start so instead of + * sending two i2c messages in a row we just send one by one. + */ + ret = i2c_master_send(state->client, buf, buf_size); + if (ret != buf_size) + return ret < 0 ? ret : -EIO; + + if (!data) + return 0; + + ret = i2c_master_recv(state->client, tmp, sizeof(tmp)); + if (ret != sizeof(tmp)) + return ret < 0 ? ret : -EIO; + + for (i = 0; i < sizeof(tmp); i += 3) { + u8 crc = crc8(sps30_crc8_table, &tmp[i], 2, CRC8_INIT_VALUE); + + if (crc != tmp[i + 2]) { + dev_err(&state->client->dev, + "data integrity check failed\n"); + return -EIO; + } + + *data++ = tmp[i]; + *data++ = tmp[i + 1]; + } + + return 0; +} + +static int sps30_do_cmd(struct sps30_state *state, u16 cmd, u8 *data, int size) +{ + /* depending on the command up to 3 bytes may be needed for argument */ + u8 buf[sizeof(cmd) + 3] = { cmd >> 8, cmd }; + + switch (cmd) { + case SPS30_START_MEAS: + buf[2] = 0x03; + buf[3] = 0x00; + buf[4] = 0xac; /* precomputed crc */ + return sps30_write_then_read(state, buf, 5, NULL, 0); + case SPS30_STOP_MEAS: + case SPS30_RESET: + return sps30_write_then_read(state, buf, 2, NULL, 0); + case SPS30_READ_DATA_READY_FLAG: + case SPS30_READ_DATA: + case SPS30_READ_SERIAL: + return sps30_write_then_read(state, buf, 2, data, size); + default: + return -EINVAL; + }; +} + +static int sps30_ieee754_to_int(const u8 *data) +{ + u32 val = ((u32)data[0] << 24) | ((u32)data[1] << 16) | + ((u32)data[2] << 8) | (u32)data[3], + mantissa = (val << 9) >> 9; + int exp = (val >> 23) - 127; + + if (!exp && !mantissa) + return 0; + + if (exp < 0) + return 0; + + return (1 << exp) + (mantissa >> (23 - exp)); +} + +static int sps30_do_meas(struct sps30_state *state, int *pm2p5, int *pm10) +{ + /* + * Internally sensor stores measurements in a following manner: + * + * PM1p0: upper two bytes, crc8, lower two bytes, crc8 + * PM2p5: upper two bytes, crc8, lower two bytes, crc8 + * PM4p0: upper two bytes, crc8, lower two bytes, crc8 + * PM10: upper two bytes, crc8, lower two bytes, crc8 + * + * What follows next are number concentration measurements and + * typical particle size measurement. + * + * Once data is read from sensor crc bytes are stripped off + * hence we need 16 bytes of buffer space. + */ + int ret, tries = 5; + u8 buf[16]; + + while (tries--) { + ret = sps30_do_cmd(state, SPS30_READ_DATA_READY_FLAG, buf, 2); + if (ret) + return -EIO; + + /* new measurements ready to be read */ + if (buf[1] == 1) + break; + + usleep_range(300000, 400000); + } + + if (!tries) + return -ETIMEDOUT; + + ret = sps30_do_cmd(state, SPS30_READ_DATA, buf, sizeof(buf)); + if (ret) + return ret; + + /* + * All measurements come in IEEE754 single precision floating point + * format but sensor itself is not precise enough (-+ 10% error) + * to take full advantage of it. Hence converting result to int + * to keep things simple. + */ + *pm2p5 = sps30_ieee754_to_int(&buf[PM2p5 * 4]); + *pm10 = sps30_ieee754_to_int(&buf[PM10 * 4]); + + return 0; +} + +static irqreturn_t sps30_trigger_handler(int irq, void *p) +{ + struct iio_poll_func *pf = p; + struct iio_dev *indio_dev = pf->indio_dev; + struct sps30_state *state = iio_priv(indio_dev); + u32 buf[4]; /* PM2p5, PM10, timestamp */ + int ret; + + mutex_lock(&state->lock); + ret = sps30_do_meas(state, &buf[0], &buf[1]); + mutex_unlock(&state->lock); + if (ret < 0) + goto err; + + iio_push_to_buffers_with_timestamp(indio_dev, buf, + iio_get_time_ns(indio_dev)); +err: + iio_trigger_notify_done(indio_dev->trig); + + return IRQ_HANDLED; +} + +static int sps30_read_raw(struct iio_dev *indio_dev, + struct iio_chan_spec const *chan, + int *val, int *val2, long mask) +{ + struct sps30_state *state = iio_priv(indio_dev); + int ret; + + switch (mask) { + case IIO_CHAN_INFO_PROCESSED: + switch (chan->type) { + case IIO_MASSCONCENTRATION: + mutex_lock(&state->lock); + switch (chan->channel2) { + case IIO_MOD_PM2p5: + ret = sps30_do_meas(state, val, val2); + break; + case IIO_MOD_PM10: + ret = sps30_do_meas(state, val2, val); + break; + default: + break; + } + mutex_unlock(&state->lock); + if (ret) + return ret; + + return IIO_VAL_INT; + default: + return -EINVAL; + } + break; + default: + return -EINVAL; + } +} + +static const struct iio_info sps30_info = { + .read_raw = sps30_read_raw, +}; + +static const struct iio_chan_spec sps30_channels[] = { + SPS30_CHAN(0, PM2p5), + SPS30_CHAN(1, PM10), + IIO_CHAN_SOFT_TIMESTAMP(2), +}; + +static const unsigned long sps30_scan_masks[] = { 0x03, 0x00 }; + +static int sps30_probe(struct i2c_client *client) +{ + struct iio_dev *indio_dev; + struct sps30_state *state; + u8 buf[32] = { }; + int ret; + + if (!i2c_check_functionality(client->adapter, I2C_FUNC_I2C)) + return -EOPNOTSUPP; + + indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*state)); + if (!indio_dev) + return -ENOMEM; + + state = iio_priv(indio_dev); + i2c_set_clientdata(client, indio_dev); + state->client = client; + indio_dev->dev.parent = &client->dev; + indio_dev->info = &sps30_info; + indio_dev->name = client->name; + indio_dev->channels = sps30_channels; + indio_dev->num_channels = ARRAY_SIZE(sps30_channels); + indio_dev->modes = INDIO_DIRECT_MODE; + indio_dev->available_scan_masks = sps30_scan_masks; + + mutex_init(&state->lock); + crc8_populate_msb(sps30_crc8_table, SPS30_CRC8_POLYNOMIAL); + + /* + * Power-on-reset causes sensor to produce some glitch on i2c bus + * and some controllers end up in error state. Recover simply + * by placing something on the bus. + */ + ret = sps30_do_cmd(state, SPS30_RESET, NULL, 0); + if (ret) { + dev_err(&client->dev, "failed to reset device\n"); + return ret; + } + usleep_range(2500000, 3500000); + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); + + ret = sps30_do_cmd(state, SPS30_READ_SERIAL, buf, sizeof(buf)); + if (ret) { + dev_err(&client->dev, "failed to read serial number\n"); + return ret; + } + dev_info(&client->dev, "serial number: %s\n", buf); + + ret = sps30_do_cmd(state, SPS30_START_MEAS, NULL, 0); + if (ret) { + dev_err(&client->dev, "failed to start measurement\n"); + return ret; + } + + ret = devm_iio_triggered_buffer_setup(&client->dev, indio_dev, NULL, + sps30_trigger_handler, NULL); + if (ret) + return ret; + + return devm_iio_device_register(&client->dev, indio_dev); +} + +static int sps30_remove(struct i2c_client *client) +{ + struct iio_dev *indio_dev = i2c_get_clientdata(client); + struct sps30_state *state = iio_priv(indio_dev); + + sps30_do_cmd(state, SPS30_STOP_MEAS, NULL, 0); + + return 0; +} + +static const struct i2c_device_id sps30_id[] = { + { "sps30" }, + { } +}; +MODULE_DEVICE_TABLE(i2c, sps30_id); + +static const struct of_device_id sps30_of_match[] = { + { .compatible = "sensirion,sps30" }, + { } +}; +MODULE_DEVICE_TABLE(of, sps30_of_match); + +static struct i2c_driver sps30_driver = { + .driver = { + .name = "sps30", + .of_match_table = sps30_of_match, + }, + .id_table = sps30_id, + .probe_new = sps30_probe, + .remove = sps30_remove, +}; +module_i2c_driver(sps30_driver); + +MODULE_AUTHOR("Tomasz Duszynski <tduszyns@gmail.com>"); +MODULE_DESCRIPTION("Sensirion SPS30 particulate matter sensor driver"); +MODULE_LICENSE("GPL v2");
Add support for Sensirion SPS30 particulate matter sensor. Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> --- drivers/iio/chemical/Kconfig | 11 ++ drivers/iio/chemical/Makefile | 1 + drivers/iio/chemical/sps30.c | 359 ++++++++++++++++++++++++++++++++++ 3 files changed, 371 insertions(+) create mode 100644 drivers/iio/chemical/sps30.c