diff mbox series

[v2] PM / devfreq: events: Fix excessive stack usage

Message ID 20191111060557.15650-1-cw00.choi@samsung.com (mailing list archive)
State Mainlined
Commit d4556f5e99d5f603913bac01adaff8670cb2d08b
Headers show
Series [v2] PM / devfreq: events: Fix excessive stack usage | expand

Commit Message

Chanwoo Choi Nov. 11, 2019, 6:05 a.m. UTC
From: Arnd Bergmann <arnd@arndb.de>

Putting a 'struct devfreq_event_dev' object on the stack is generally
a bad idea and here it leads to a warnig about potential stack overflow:

drivers/devfreq/event/exynos-ppmu.c:643:12: error: stack frame size of 1040 bytes in function 'exynos_ppmu_probe' [-Werror,-Wframe-larger-than=]

There is no real need for the device structure, only the string inside
it, so add an internal helper function that simply takes the string
as its argument and remove the device structure.

Fixes: 1dd62c66d345 ("PM / devfreq: events: extend events by type of counted data")
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
[cw00.choi: Fix the issue from 'desc->name' to 'desc[j].name']
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
---
Changes from v1:
- Fix the issue from 'desc->name' to 'desc[j].name'

 drivers/devfreq/event/exynos-ppmu.c | 13 ++++++++-----
 1 file changed, 8 insertions(+), 5 deletions(-)

Comments

Chanwoo Choi Nov. 11, 2019, 6:07 a.m. UTC | #1
On 11/11/19 3:05 PM, Chanwoo Choi wrote:
> From: Arnd Bergmann <arnd@arndb.de>
> 
> Putting a 'struct devfreq_event_dev' object on the stack is generally
> a bad idea and here it leads to a warnig about potential stack overflow:
> 
> drivers/devfreq/event/exynos-ppmu.c:643:12: error: stack frame size of 1040 bytes in function 'exynos_ppmu_probe' [-Werror,-Wframe-larger-than=]
> 
> There is no real need for the device structure, only the string inside
> it, so add an internal helper function that simply takes the string
> as its argument and remove the device structure.
> 
> Fixes: 1dd62c66d345 ("PM / devfreq: events: extend events by type of counted data")
> Signed-off-by: Arnd Bergmann <arnd@arndb.de>
> [cw00.choi: Fix the issue from 'desc->name' to 'desc[j].name']
> Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
> ---
> Changes from v1:
> - Fix the issue from 'desc->name' to 'desc[j].name'
> 
>  drivers/devfreq/event/exynos-ppmu.c | 13 ++++++++-----
>  1 file changed, 8 insertions(+), 5 deletions(-)
> 
> diff --git a/drivers/devfreq/event/exynos-ppmu.c b/drivers/devfreq/event/exynos-ppmu.c
> index 85c7a77bf3f0..055deea42c37 100644
> --- a/drivers/devfreq/event/exynos-ppmu.c
> +++ b/drivers/devfreq/event/exynos-ppmu.c
> @@ -101,17 +101,22 @@ static struct __exynos_ppmu_events {
>  	PPMU_EVENT(dmc1_1),
>  };
>  
> -static int exynos_ppmu_find_ppmu_id(struct devfreq_event_dev *edev)
> +static int __exynos_ppmu_find_ppmu_id(const char *edev_name)
>  {
>  	int i;
>  
>  	for (i = 0; i < ARRAY_SIZE(ppmu_events); i++)
> -		if (!strcmp(edev->desc->name, ppmu_events[i].name))
> +		if (!strcmp(edev_name, ppmu_events[i].name))
>  			return ppmu_events[i].id;
>  
>  	return -EINVAL;
>  }
>  
> +static int exynos_ppmu_find_ppmu_id(struct devfreq_event_dev *edev)
> +{
> +	return __exynos_ppmu_find_ppmu_id(edev->desc->name);
> +}
> +
>  /*
>   * The devfreq-event ops structure for PPMU v1.1
>   */
> @@ -556,13 +561,11 @@ static int of_get_devfreq_events(struct device_node *np,
>  			 * use default if not.
>  			 */
>  			if (info->ppmu_type == EXYNOS_TYPE_PPMU_V2) {
> -				struct devfreq_event_dev edev;
>  				int id;
>  				/* Not all registers take the same value for
>  				 * read+write data count.
>  				 */
> -				edev.desc = &desc[j];
> -				id = exynos_ppmu_find_ppmu_id(&edev);
> +				id = __exynos_ppmu_find_ppmu_id(desc[j].name);
>  
>  				switch (id) {
>  				case PPMU_PMNCNT0:
> 

Applied it. Thanks.
diff mbox series

Patch

diff --git a/drivers/devfreq/event/exynos-ppmu.c b/drivers/devfreq/event/exynos-ppmu.c
index 85c7a77bf3f0..055deea42c37 100644
--- a/drivers/devfreq/event/exynos-ppmu.c
+++ b/drivers/devfreq/event/exynos-ppmu.c
@@ -101,17 +101,22 @@  static struct __exynos_ppmu_events {
 	PPMU_EVENT(dmc1_1),
 };
 
-static int exynos_ppmu_find_ppmu_id(struct devfreq_event_dev *edev)
+static int __exynos_ppmu_find_ppmu_id(const char *edev_name)
 {
 	int i;
 
 	for (i = 0; i < ARRAY_SIZE(ppmu_events); i++)
-		if (!strcmp(edev->desc->name, ppmu_events[i].name))
+		if (!strcmp(edev_name, ppmu_events[i].name))
 			return ppmu_events[i].id;
 
 	return -EINVAL;
 }
 
+static int exynos_ppmu_find_ppmu_id(struct devfreq_event_dev *edev)
+{
+	return __exynos_ppmu_find_ppmu_id(edev->desc->name);
+}
+
 /*
  * The devfreq-event ops structure for PPMU v1.1
  */
@@ -556,13 +561,11 @@  static int of_get_devfreq_events(struct device_node *np,
 			 * use default if not.
 			 */
 			if (info->ppmu_type == EXYNOS_TYPE_PPMU_V2) {
-				struct devfreq_event_dev edev;
 				int id;
 				/* Not all registers take the same value for
 				 * read+write data count.
 				 */
-				edev.desc = &desc[j];
-				id = exynos_ppmu_find_ppmu_id(&edev);
+				id = __exynos_ppmu_find_ppmu_id(desc[j].name);
 
 				switch (id) {
 				case PPMU_PMNCNT0: