Message ID | 20201022074551.11520-1-alexandru.ardelean@analog.com (mailing list archive) |
---|---|
State | Not Applicable |
Delegated to: | Netdev Maintainers |
Headers | show |
Series | [v2,1/2] net: phy: adin: disable diag clock & disable standby mode in config_aneg | expand |
On Thu, Oct 22, 2020 at 10:45:50AM +0300, Alexandru Ardelean wrote: > When the PHY powers up, the diagnostics clock isn't enabled (bit 2 in > register PHY_CTRL_1 (0x0012)). > Also, the PHY is not in standby mode, so bit 13 in PHY_CTRL_3 (0x0017) is > always set at power up. > > The standby mode and the diagnostics clock are both meant to be for the > cable diagnostics feature of the PHY (in phylib this would be equivalent to > the cable-test support), and for the frame-generator feature of the PHY. > > In standby mode, the PHY doesn't negotiate links or manage links. > > To use the cable diagnostics/test (or frame-generator), the PHY must be > first set in standby mode, so that the link operation doesn't interfere. > Then, the diagnostics clock must be enabled. > > For the cable-test feature, when the operation finishes, the PHY goes into > PHY_UP state, and the config_aneg hook is called. > > For the ADIN PHY, we need to make sure that during autonegotiation > configuration/setup the PHY is removed from standby mode and the > diagnostics clock is disabled, so that normal operation is resumed. > > This change does that by moving the set of the ADIN1300_LINKING_EN bit (2) > in the config_aneg (to disable standby mode). > Previously, this was set in the downshift setup, because the downshift > retry value and the ADIN1300_LINKING_EN are in the same register. > > And the ADIN1300_DIAG_CLK_EN bit (13) is cleared, to disable the > diagnostics clock. > > Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Andrew
On Sat, Oct 24, 2020 at 1:43 AM Andrew Lunn <andrew@lunn.ch> wrote: > > On Thu, Oct 22, 2020 at 10:45:50AM +0300, Alexandru Ardelean wrote: > > When the PHY powers up, the diagnostics clock isn't enabled (bit 2 in > > register PHY_CTRL_1 (0x0012)). > > Also, the PHY is not in standby mode, so bit 13 in PHY_CTRL_3 (0x0017) is > > always set at power up. > > > > The standby mode and the diagnostics clock are both meant to be for the > > cable diagnostics feature of the PHY (in phylib this would be equivalent to > > the cable-test support), and for the frame-generator feature of the PHY. > > > > In standby mode, the PHY doesn't negotiate links or manage links. > > > > To use the cable diagnostics/test (or frame-generator), the PHY must be > > first set in standby mode, so that the link operation doesn't interfere. > > Then, the diagnostics clock must be enabled. > > > > For the cable-test feature, when the operation finishes, the PHY goes into > > PHY_UP state, and the config_aneg hook is called. > > > > For the ADIN PHY, we need to make sure that during autonegotiation > > configuration/setup the PHY is removed from standby mode and the > > diagnostics clock is disabled, so that normal operation is resumed. > > > > This change does that by moving the set of the ADIN1300_LINKING_EN bit (2) > > in the config_aneg (to disable standby mode). > > Previously, this was set in the downshift setup, because the downshift > > retry value and the ADIN1300_LINKING_EN are in the same register. > > > > And the ADIN1300_DIAG_CLK_EN bit (13) is cleared, to disable the > > diagnostics clock. > > > > Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com> > > Reviewed-by: Andrew Lunn <andrew@lunn.ch> So, then re-send for this or just this patch ping? Naturally, this is for net-next. I don't mind doing either way. Thanks Alex > > Andrew
> So, then re-send for this or just this patch ping? > Naturally, this is for net-next. > I don't mind doing either way. Please resend, with all the acked-by, reviewed-by added, now that net-next is open. Andrew
diff --git a/drivers/net/phy/adin.c b/drivers/net/phy/adin.c index 5bc3926c52f0..619d36685b5d 100644 --- a/drivers/net/phy/adin.c +++ b/drivers/net/phy/adin.c @@ -23,6 +23,7 @@ #define ADIN1300_PHY_CTRL1 0x0012 #define ADIN1300_AUTO_MDI_EN BIT(10) #define ADIN1300_MAN_MDIX_EN BIT(9) +#define ADIN1300_DIAG_CLK_EN BIT(2) #define ADIN1300_RX_ERR_CNT 0x0014 @@ -326,10 +327,9 @@ static int adin_set_downshift(struct phy_device *phydev, u8 cnt) return -E2BIG; val = FIELD_PREP(ADIN1300_DOWNSPEED_RETRIES_MSK, cnt); - val |= ADIN1300_LINKING_EN; rc = phy_modify(phydev, ADIN1300_PHY_CTRL3, - ADIN1300_LINKING_EN | ADIN1300_DOWNSPEED_RETRIES_MSK, + ADIN1300_DOWNSPEED_RETRIES_MSK, val); if (rc < 0) return rc; @@ -560,6 +560,14 @@ static int adin_config_aneg(struct phy_device *phydev) { int ret; + ret = phy_clear_bits(phydev, ADIN1300_PHY_CTRL1, ADIN1300_DIAG_CLK_EN); + if (ret < 0) + return ret; + + ret = phy_set_bits(phydev, ADIN1300_PHY_CTRL3, ADIN1300_LINKING_EN); + if (ret < 0) + return ret; + ret = adin_config_mdix(phydev); if (ret) return ret;
When the PHY powers up, the diagnostics clock isn't enabled (bit 2 in register PHY_CTRL_1 (0x0012)). Also, the PHY is not in standby mode, so bit 13 in PHY_CTRL_3 (0x0017) is always set at power up. The standby mode and the diagnostics clock are both meant to be for the cable diagnostics feature of the PHY (in phylib this would be equivalent to the cable-test support), and for the frame-generator feature of the PHY. In standby mode, the PHY doesn't negotiate links or manage links. To use the cable diagnostics/test (or frame-generator), the PHY must be first set in standby mode, so that the link operation doesn't interfere. Then, the diagnostics clock must be enabled. For the cable-test feature, when the operation finishes, the PHY goes into PHY_UP state, and the config_aneg hook is called. For the ADIN PHY, we need to make sure that during autonegotiation configuration/setup the PHY is removed from standby mode and the diagnostics clock is disabled, so that normal operation is resumed. This change does that by moving the set of the ADIN1300_LINKING_EN bit (2) in the config_aneg (to disable standby mode). Previously, this was set in the downshift setup, because the downshift retry value and the ADIN1300_LINKING_EN are in the same register. And the ADIN1300_DIAG_CLK_EN bit (13) is cleared, to disable the diagnostics clock. Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com> --- Changelog v1 -> v2: * updated title; updated description to better describe the diagnostics clock & standby mode, and what they mean for the PHY drivers/net/phy/adin.c | 12 ++++++++++-- 1 file changed, 10 insertions(+), 2 deletions(-)