Message ID | a14f98e1b23ea14cf14da3c3169955343ec28bbe.1632994837.git.mchehab+huawei@kernel.org (mailing list archive) |
---|---|
State | Changes Requested |
Headers | show |
Series | ABI: add additional sysfs docs and update some other ABI files | expand |
On 9/30/21 2:44 AM, Mauro Carvalho Chehab wrote: > Such ABI symbol is currently not described. Document it. > > Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org> > --- > > See [PATCH v2 0/7] at: https://lore.kernel.org/all/cover.1632994837.git.mchehab+huawei@kernel.org/ > > Documentation/ABI/testing/sysfs-class-hwmon | 14 ++++++++++++++ > 1 file changed, 14 insertions(+) > > diff --git a/Documentation/ABI/testing/sysfs-class-hwmon b/Documentation/ABI/testing/sysfs-class-hwmon > index ea5a129ae082..1f20687def44 100644 > --- a/Documentation/ABI/testing/sysfs-class-hwmon > +++ b/Documentation/ABI/testing/sysfs-class-hwmon > @@ -410,6 +410,20 @@ Description: > > RW > > +What: /sys/class/hwmon/hwmonX/tempY_crit_alarm > +Description: > + Critical high temperature alarm flag. > + > + - 0: OK > + - 1: temperature has reached tempY_crit > + > + RW > + > + Contrary to regular alarm flags which clear themselves > + automatically when read, this one sticks until cleared by > + the user. This is done by writing 0 to the file. Writing > + other values is unsupported. > + That is not really correct. It _may_ be current implementation for some drivers, but such an implementation would not be correct. The proper implementation would be to auto-clear the flag after it was read unless the condition persists. > What: /sys/class/hwmon/hwmonX/tempY_crit_hyst > Description: > Temperature hysteresis value for critical limit. > This should be documented as part of the previous patch, together with all other alarm attributes. Guenter
diff --git a/Documentation/ABI/testing/sysfs-class-hwmon b/Documentation/ABI/testing/sysfs-class-hwmon index ea5a129ae082..1f20687def44 100644 --- a/Documentation/ABI/testing/sysfs-class-hwmon +++ b/Documentation/ABI/testing/sysfs-class-hwmon @@ -410,6 +410,20 @@ Description: RW +What: /sys/class/hwmon/hwmonX/tempY_crit_alarm +Description: + Critical high temperature alarm flag. + + - 0: OK + - 1: temperature has reached tempY_crit + + RW + + Contrary to regular alarm flags which clear themselves + automatically when read, this one sticks until cleared by + the user. This is done by writing 0 to the file. Writing + other values is unsupported. + What: /sys/class/hwmon/hwmonX/tempY_crit_hyst Description: Temperature hysteresis value for critical limit.
Such ABI symbol is currently not described. Document it. Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org> --- See [PATCH v2 0/7] at: https://lore.kernel.org/all/cover.1632994837.git.mchehab+huawei@kernel.org/ Documentation/ABI/testing/sysfs-class-hwmon | 14 ++++++++++++++ 1 file changed, 14 insertions(+)