Message ID | YmTcrq8Gzel0zYYD@jackdesk (mailing list archive) |
---|---|
State | Accepted |
Headers | show |
Series | [v2] hwmon: (aquacomputer_d5next) Add support for Aquacomputer Farbwerk | expand |
On Sun, Apr 24, 2022 at 12:14:22AM -0500, Jack Doan wrote: > Extend aquacomputer_d5next driver to expose hardware > temperature sensors of the Aquacomputer Farbwerk RGB controller, which > communicates through a proprietary USB HID protocol. > > Four temperature sensors are available. Additionally, serial number and > firmware version are exposed through debugfs. > > Also, add Jack Doan to MAINTAINERS for this driver. > > Signed-off-by: Jack Doan <me@jackdoan.com> > Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Applied. Thanks, Guenter > --- > Changes in v2: > - update Kconfig so it applies cleanly > - add "select CRC16" to Kconfig > --- > Documentation/hwmon/aquacomputer_d5next.rst | 3 +- > MAINTAINERS | 1 + > drivers/hwmon/Kconfig | 5 +-- > drivers/hwmon/aquacomputer_d5next.c | 37 ++++++++++++++++++--- > 4 files changed, 38 insertions(+), 8 deletions(-) > > diff --git a/Documentation/hwmon/aquacomputer_d5next.rst b/Documentation/hwmon/aquacomputer_d5next.rst > index e69f718caf5b..717e28226cde 100644 > --- a/Documentation/hwmon/aquacomputer_d5next.rst > +++ b/Documentation/hwmon/aquacomputer_d5next.rst > @@ -6,6 +6,7 @@ Kernel driver aquacomputer-d5next > Supported devices: > > * Aquacomputer D5 Next watercooling pump > +* Aquacomputer Farbwerk RGB controller > * Aquacomputer Farbwerk 360 RGB controller > * Aquacomputer Octo fan controller > > @@ -32,7 +33,7 @@ better suited for userspace tools. > The Octo exposes four temperature sensors and eight PWM controllable fans, along > with their speed (in RPM), power, voltage and current. > > -The Farbwerk 360 exposes four temperature sensors. Depending on the device, > +The Farbwerk and Farbwerk 360 expose four temperature sensors. Depending on the device, > not all sysfs and debugfs entries will be available. > > Usage notes > diff --git a/MAINTAINERS b/MAINTAINERS > index fd768d43e048..c5cd8dd866ee 100644 > --- a/MAINTAINERS > +++ b/MAINTAINERS > @@ -1446,6 +1446,7 @@ F: drivers/media/i2c/aptina-pll.* > > AQUACOMPUTER D5 NEXT PUMP SENSOR DRIVER > M: Aleksa Savic <savicaleksa83@gmail.com> > +M: Jack Doan <me@jackdoan.com> > L: linux-hwmon@vger.kernel.org > S: Maintained > F: Documentation/hwmon/aquacomputer_d5next.rst > diff --git a/drivers/hwmon/Kconfig b/drivers/hwmon/Kconfig > index 1f1bb4d858cb..4a6d6c5b9b69 100644 > --- a/drivers/hwmon/Kconfig > +++ b/drivers/hwmon/Kconfig > @@ -256,13 +256,14 @@ config SENSORS_AHT10 > will be called aht10. > > config SENSORS_AQUACOMPUTER_D5NEXT > - tristate "Aquacomputer D5 Next, Octo and Farbwerk 360" > + tristate "Aquacomputer D5 Next, Octo, Farbwerk, and Farbwerk 360" > depends on USB_HID > select CRC16 > help > If you say yes here you get support for sensors and fans of > the Aquacomputer D5 Next watercooling pump, Octo fan > - controller and Farbwerk 360 RGB controller, where available. > + controller, Farbwerk and Farbwerk 360 RGB controllers, where > + available. > > This driver can also be built as a module. If so, the module > will be called aquacomputer_d5next. > diff --git a/drivers/hwmon/aquacomputer_d5next.c b/drivers/hwmon/aquacomputer_d5next.c > index a464473bc981..7d2e7279abfb 100644 > --- a/drivers/hwmon/aquacomputer_d5next.c > +++ b/drivers/hwmon/aquacomputer_d5next.c > @@ -1,11 +1,12 @@ > // SPDX-License-Identifier: GPL-2.0+ > /* > - * hwmon driver for Aquacomputer devices (D5 Next, Farbwerk 360, Octo) > + * hwmon driver for Aquacomputer devices (D5 Next, Farbwerk, Farbwerk 360, Octo) > * > * Aquacomputer devices send HID reports (with ID 0x01) every second to report > * sensor values. > * > * Copyright 2021 Aleksa Savic <savicaleksa83@gmail.com> > + * Copyright 2022 Jack Doan <me@jackdoan.com> > */ > > #include <linux/crc16.h> > @@ -19,14 +20,16 @@ > #include <asm/unaligned.h> > > #define USB_VENDOR_ID_AQUACOMPUTER 0x0c70 > +#define USB_PRODUCT_ID_FARBWERK 0xf00a > #define USB_PRODUCT_ID_D5NEXT 0xf00e > #define USB_PRODUCT_ID_FARBWERK360 0xf010 > #define USB_PRODUCT_ID_OCTO 0xf011 > > -enum kinds { d5next, farbwerk360, octo }; > +enum kinds { d5next, farbwerk, farbwerk360, octo }; > > static const char *const aqc_device_names[] = { > [d5next] = "d5next", > + [farbwerk] = "farbwerk", > [farbwerk360] = "farbwerk360", > [octo] = "octo" > }; > @@ -69,6 +72,12 @@ static u8 secondary_ctrl_report[] = { > #define D5NEXT_PUMP_CURRENT 112 > #define D5NEXT_FAN_CURRENT 99 > > +/* Register offsets for the Farbwerk RGB controller */ > +#define FARBWERK_NUM_SENSORS 4 > +#define FARBWERK_SENSOR_START 0x2f > +#define FARBWERK_SENSOR_SIZE 0x02 > +#define FARBWERK_SENSOR_DISCONNECTED 0x7FFF > + > /* Register offsets for the Farbwerk 360 RGB controller */ > #define FARBWERK360_NUM_SENSORS 4 > #define FARBWERK360_SENSOR_START 0x32 > @@ -125,7 +134,7 @@ static const char *const label_d5next_current[] = { > "Fan current" > }; > > -/* Labels for Farbwerk 360 and Octo temperature sensors */ > +/* Labels for Farbwerk, Farbwerk 360 and Octo temperature sensors */ > static const char *const label_temp_sensors[] = { > "Sensor 1", > "Sensor 2", > @@ -319,6 +328,7 @@ static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3 > if (channel == 0) > return 0444; > break; > + case farbwerk: > case farbwerk360: > case octo: > return 0444; > @@ -551,8 +561,7 @@ static const struct hwmon_chip_info aqc_chip_info = { > .info = aqc_info, > }; > > -static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8 *data, > - int size) > +static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8 *data, int size) > { > int i, sensor_value; > struct aqc_data *priv; > @@ -587,6 +596,17 @@ static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8 > priv->current_input[0] = get_unaligned_be16(data + D5NEXT_PUMP_CURRENT); > priv->current_input[1] = get_unaligned_be16(data + D5NEXT_FAN_CURRENT); > break; > + case farbwerk: > + /* Temperature sensor readings */ > + for (i = 0; i < FARBWERK_NUM_SENSORS; i++) { > + sensor_value = get_unaligned_be16(data + FARBWERK_SENSOR_START + > + i * FARBWERK_SENSOR_SIZE); > + if (sensor_value == FARBWERK_SENSOR_DISCONNECTED) > + priv->temp_input[i] = -ENODATA; > + else > + priv->temp_input[i] = sensor_value * 10; > + } > + break; > case farbwerk360: > /* Temperature sensor readings */ > for (i = 0; i < FARBWERK360_NUM_SENSORS; i++) { > @@ -733,6 +753,11 @@ static int aqc_probe(struct hid_device *hdev, const struct hid_device_id *id) > priv->voltage_label = label_d5next_voltages; > priv->current_label = label_d5next_current; > break; > + case USB_PRODUCT_ID_FARBWERK: > + priv->kind = farbwerk; > + > + priv->temp_label = label_temp_sensors; > + break; > case USB_PRODUCT_ID_FARBWERK360: > priv->kind = farbwerk360; > > @@ -795,6 +820,7 @@ static void aqc_remove(struct hid_device *hdev) > > static const struct hid_device_id aqc_table[] = { > { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_D5NEXT) }, > + { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_FARBWERK) }, > { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_FARBWERK360) }, > { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_OCTO) }, > { } > @@ -826,4 +852,5 @@ module_exit(aqc_exit); > > MODULE_LICENSE("GPL"); > MODULE_AUTHOR("Aleksa Savic <savicaleksa83@gmail.com>"); > +MODULE_AUTHOR("Jack Doan <me@jackdoan.com>"); > MODULE_DESCRIPTION("Hwmon driver for Aquacomputer devices");
Thank you! Aleksa
diff --git a/Documentation/hwmon/aquacomputer_d5next.rst b/Documentation/hwmon/aquacomputer_d5next.rst index e69f718caf5b..717e28226cde 100644 --- a/Documentation/hwmon/aquacomputer_d5next.rst +++ b/Documentation/hwmon/aquacomputer_d5next.rst @@ -6,6 +6,7 @@ Kernel driver aquacomputer-d5next Supported devices: * Aquacomputer D5 Next watercooling pump +* Aquacomputer Farbwerk RGB controller * Aquacomputer Farbwerk 360 RGB controller * Aquacomputer Octo fan controller @@ -32,7 +33,7 @@ better suited for userspace tools. The Octo exposes four temperature sensors and eight PWM controllable fans, along with their speed (in RPM), power, voltage and current. -The Farbwerk 360 exposes four temperature sensors. Depending on the device, +The Farbwerk and Farbwerk 360 expose four temperature sensors. Depending on the device, not all sysfs and debugfs entries will be available. Usage notes diff --git a/MAINTAINERS b/MAINTAINERS index fd768d43e048..c5cd8dd866ee 100644 --- a/MAINTAINERS +++ b/MAINTAINERS @@ -1446,6 +1446,7 @@ F: drivers/media/i2c/aptina-pll.* AQUACOMPUTER D5 NEXT PUMP SENSOR DRIVER M: Aleksa Savic <savicaleksa83@gmail.com> +M: Jack Doan <me@jackdoan.com> L: linux-hwmon@vger.kernel.org S: Maintained F: Documentation/hwmon/aquacomputer_d5next.rst diff --git a/drivers/hwmon/Kconfig b/drivers/hwmon/Kconfig index 1f1bb4d858cb..4a6d6c5b9b69 100644 --- a/drivers/hwmon/Kconfig +++ b/drivers/hwmon/Kconfig @@ -256,13 +256,14 @@ config SENSORS_AHT10 will be called aht10. config SENSORS_AQUACOMPUTER_D5NEXT - tristate "Aquacomputer D5 Next, Octo and Farbwerk 360" + tristate "Aquacomputer D5 Next, Octo, Farbwerk, and Farbwerk 360" depends on USB_HID select CRC16 help If you say yes here you get support for sensors and fans of the Aquacomputer D5 Next watercooling pump, Octo fan - controller and Farbwerk 360 RGB controller, where available. + controller, Farbwerk and Farbwerk 360 RGB controllers, where + available. This driver can also be built as a module. If so, the module will be called aquacomputer_d5next. diff --git a/drivers/hwmon/aquacomputer_d5next.c b/drivers/hwmon/aquacomputer_d5next.c index a464473bc981..7d2e7279abfb 100644 --- a/drivers/hwmon/aquacomputer_d5next.c +++ b/drivers/hwmon/aquacomputer_d5next.c @@ -1,11 +1,12 @@ // SPDX-License-Identifier: GPL-2.0+ /* - * hwmon driver for Aquacomputer devices (D5 Next, Farbwerk 360, Octo) + * hwmon driver for Aquacomputer devices (D5 Next, Farbwerk, Farbwerk 360, Octo) * * Aquacomputer devices send HID reports (with ID 0x01) every second to report * sensor values. * * Copyright 2021 Aleksa Savic <savicaleksa83@gmail.com> + * Copyright 2022 Jack Doan <me@jackdoan.com> */ #include <linux/crc16.h> @@ -19,14 +20,16 @@ #include <asm/unaligned.h> #define USB_VENDOR_ID_AQUACOMPUTER 0x0c70 +#define USB_PRODUCT_ID_FARBWERK 0xf00a #define USB_PRODUCT_ID_D5NEXT 0xf00e #define USB_PRODUCT_ID_FARBWERK360 0xf010 #define USB_PRODUCT_ID_OCTO 0xf011 -enum kinds { d5next, farbwerk360, octo }; +enum kinds { d5next, farbwerk, farbwerk360, octo }; static const char *const aqc_device_names[] = { [d5next] = "d5next", + [farbwerk] = "farbwerk", [farbwerk360] = "farbwerk360", [octo] = "octo" }; @@ -69,6 +72,12 @@ static u8 secondary_ctrl_report[] = { #define D5NEXT_PUMP_CURRENT 112 #define D5NEXT_FAN_CURRENT 99 +/* Register offsets for the Farbwerk RGB controller */ +#define FARBWERK_NUM_SENSORS 4 +#define FARBWERK_SENSOR_START 0x2f +#define FARBWERK_SENSOR_SIZE 0x02 +#define FARBWERK_SENSOR_DISCONNECTED 0x7FFF + /* Register offsets for the Farbwerk 360 RGB controller */ #define FARBWERK360_NUM_SENSORS 4 #define FARBWERK360_SENSOR_START 0x32 @@ -125,7 +134,7 @@ static const char *const label_d5next_current[] = { "Fan current" }; -/* Labels for Farbwerk 360 and Octo temperature sensors */ +/* Labels for Farbwerk, Farbwerk 360 and Octo temperature sensors */ static const char *const label_temp_sensors[] = { "Sensor 1", "Sensor 2", @@ -319,6 +328,7 @@ static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3 if (channel == 0) return 0444; break; + case farbwerk: case farbwerk360: case octo: return 0444; @@ -551,8 +561,7 @@ static const struct hwmon_chip_info aqc_chip_info = { .info = aqc_info, }; -static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8 *data, - int size) +static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8 *data, int size) { int i, sensor_value; struct aqc_data *priv; @@ -587,6 +596,17 @@ static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8 priv->current_input[0] = get_unaligned_be16(data + D5NEXT_PUMP_CURRENT); priv->current_input[1] = get_unaligned_be16(data + D5NEXT_FAN_CURRENT); break; + case farbwerk: + /* Temperature sensor readings */ + for (i = 0; i < FARBWERK_NUM_SENSORS; i++) { + sensor_value = get_unaligned_be16(data + FARBWERK_SENSOR_START + + i * FARBWERK_SENSOR_SIZE); + if (sensor_value == FARBWERK_SENSOR_DISCONNECTED) + priv->temp_input[i] = -ENODATA; + else + priv->temp_input[i] = sensor_value * 10; + } + break; case farbwerk360: /* Temperature sensor readings */ for (i = 0; i < FARBWERK360_NUM_SENSORS; i++) { @@ -733,6 +753,11 @@ static int aqc_probe(struct hid_device *hdev, const struct hid_device_id *id) priv->voltage_label = label_d5next_voltages; priv->current_label = label_d5next_current; break; + case USB_PRODUCT_ID_FARBWERK: + priv->kind = farbwerk; + + priv->temp_label = label_temp_sensors; + break; case USB_PRODUCT_ID_FARBWERK360: priv->kind = farbwerk360; @@ -795,6 +820,7 @@ static void aqc_remove(struct hid_device *hdev) static const struct hid_device_id aqc_table[] = { { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_D5NEXT) }, + { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_FARBWERK) }, { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_FARBWERK360) }, { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_OCTO) }, { } @@ -826,4 +852,5 @@ module_exit(aqc_exit); MODULE_LICENSE("GPL"); MODULE_AUTHOR("Aleksa Savic <savicaleksa83@gmail.com>"); +MODULE_AUTHOR("Jack Doan <me@jackdoan.com>"); MODULE_DESCRIPTION("Hwmon driver for Aquacomputer devices");