Series | thermal/drivers/qcom/temp-alarm: fix inaccurate warning for gen2 | expand |
On Thu, Oct 20, 2022 at 8:23 PM Luca Weiss <luca.weiss@fairphone.com> wrote: > > On gen2 chips the stage2 threshold is not 140 degC but 125 degC. > > Make the warning message clearer by using this variable and also by > including the temperature that was checked for. > > Fixes: aa92b3310c55 ("thermal/drivers/qcom-spmi-temp-alarm: Add support for GEN2 rev 1 PMIC peripherals") > Signed-off-by: Luca Weiss <luca.weiss@fairphone.com> Reviewed-by: Amit Kucheria <amitk@kernel.org> > --- > drivers/thermal/qcom/qcom-spmi-temp-alarm.c | 3 ++- > 1 file changed, 2 insertions(+), 1 deletion(-) > > diff --git a/drivers/thermal/qcom/qcom-spmi-temp-alarm.c b/drivers/thermal/qcom/qcom-spmi-temp-alarm.c > index be785ab37e53..ad84978109e6 100644 > --- a/drivers/thermal/qcom/qcom-spmi-temp-alarm.c > +++ b/drivers/thermal/qcom/qcom-spmi-temp-alarm.c > @@ -252,7 +252,8 @@ static int qpnp_tm_update_critical_trip_temp(struct qpnp_tm_chip *chip, > disable_s2_shutdown = true; > else > dev_warn(chip->dev, > - "No ADC is configured and critical temperature is above the maximum stage 2 threshold of 140 C! Configuring stage 2 shutdown at 140 C.\n"); > + "No ADC is configured and critical temperature %d mC is above the maximum stage 2 threshold of %ld mC! Configuring stage 2 shutdown at %ld mC.\n", > + temp, stage2_threshold_max, stage2_threshold_max); > } > > skip: > -- > 2.38.1 >
diff --git a/drivers/thermal/qcom/qcom-spmi-temp-alarm.c b/drivers/thermal/qcom/qcom-spmi-temp-alarm.c index be785ab37e53..ad84978109e6 100644 --- a/drivers/thermal/qcom/qcom-spmi-temp-alarm.c +++ b/drivers/thermal/qcom/qcom-spmi-temp-alarm.c @@ -252,7 +252,8 @@ static int qpnp_tm_update_critical_trip_temp(struct qpnp_tm_chip *chip, disable_s2_shutdown = true; else dev_warn(chip->dev, - "No ADC is configured and critical temperature is above the maximum stage 2 threshold of 140 C! Configuring stage 2 shutdown at 140 C.\n"); + "No ADC is configured and critical temperature %d mC is above the maximum stage 2 threshold of %ld mC! Configuring stage 2 shutdown at %ld mC.\n", + temp, stage2_threshold_max, stage2_threshold_max); } skip:
On gen2 chips the stage2 threshold is not 140 degC but 125 degC. Make the warning message clearer by using this variable and also by including the temperature that was checked for. Fixes: aa92b3310c55 ("thermal/drivers/qcom-spmi-temp-alarm: Add support for GEN2 rev 1 PMIC peripherals") Signed-off-by: Luca Weiss <luca.weiss@fairphone.com> --- drivers/thermal/qcom/qcom-spmi-temp-alarm.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)