thermal: qcom-spmi-temp-alarm: Log the actual max stage 2 threshold

Message ID 20221025171453.1.I13c2a23f276fb63bfc225aeab0bf0db9560a90e0@changeid (mailing list archive)
State New, archived
Delegated to: Daniel Lezcano
Headers show
Series thermal: qcom-spmi-temp-alarm: Log the actual max stage 2 threshold | expand

Commit Message

Matthias Kaehlcke Oct. 25, 2022, 5:15 p.m. UTC
If the critical trip point of the thermal zone is higher than
the max threshold of the PMIC log the actual max threshold of the
chip, not the gen1 max threshold of 140°C.

Reported-by: Luca Weiss <luca.weiss@fairphone.com>
Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
---

 drivers/thermal/qcom/qcom-spmi-temp-alarm.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

Comments

Matthias Kaehlcke Oct. 25, 2022, 9:33 p.m. UTC | #1
I just saw that Luca already posted a similar patch:

https://lore.kernel.org/lkml/CAHLCerN+-5qKsRmpuF55RdeUMZJZuiZJ-7O4LnM8+QuHJfs0mQ@mail.gmail.com/T/

Please disregard this one.

On Tue, Oct 25, 2022 at 05:15:08PM +0000, Matthias Kaehlcke wrote:
> If the critical trip point of the thermal zone is higher than
> the max threshold of the PMIC log the actual max threshold of the
> chip, not the gen1 max threshold of 140°C.
> 
> Reported-by: Luca Weiss <luca.weiss@fairphone.com>
> Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
> ---
> 
>  drivers/thermal/qcom/qcom-spmi-temp-alarm.c | 3 ++-
>  1 file changed, 2 insertions(+), 1 deletion(-)
> 
> diff --git a/drivers/thermal/qcom/qcom-spmi-temp-alarm.c b/drivers/thermal/qcom/qcom-spmi-temp-alarm.c
> index be785ab37e53..bdfe2129c357 100644
> --- a/drivers/thermal/qcom/qcom-spmi-temp-alarm.c
> +++ b/drivers/thermal/qcom/qcom-spmi-temp-alarm.c
> @@ -252,7 +252,8 @@ static int qpnp_tm_update_critical_trip_temp(struct qpnp_tm_chip *chip,
>  			disable_s2_shutdown = true;
>  		else
>  			dev_warn(chip->dev,
> -				 "No ADC is configured and critical temperature is above the maximum stage 2 threshold of 140 C! Configuring stage 2 shutdown at 140 C.\n");
> +				 "No ADC is configured and critical temperature is above the maximum stage 2 threshold of %d C! Configuring stage 2 shutdown at %d C.\n",
> +				 stage2_threshold_max / 1000, stage2_threshold_max / 1000);
>  	}
>  
>  skip:
> -- 
> 2.38.0.135.g90850a2211-goog
>
diff mbox series

Patch

diff --git a/drivers/thermal/qcom/qcom-spmi-temp-alarm.c b/drivers/thermal/qcom/qcom-spmi-temp-alarm.c
index be785ab37e53..bdfe2129c357 100644
--- a/drivers/thermal/qcom/qcom-spmi-temp-alarm.c
+++ b/drivers/thermal/qcom/qcom-spmi-temp-alarm.c
@@ -252,7 +252,8 @@  static int qpnp_tm_update_critical_trip_temp(struct qpnp_tm_chip *chip,
 			disable_s2_shutdown = true;
 		else
 			dev_warn(chip->dev,
-				 "No ADC is configured and critical temperature is above the maximum stage 2 threshold of 140 C! Configuring stage 2 shutdown at 140 C.\n");
+				 "No ADC is configured and critical temperature is above the maximum stage 2 threshold of %d C! Configuring stage 2 shutdown at %d C.\n",
+				 stage2_threshold_max / 1000, stage2_threshold_max / 1000);
 	}
 
 skip: