Message ID | 1342434670.4717.6.camel@phoenix (mailing list archive) |
---|---|
State | New, archived |
Headers | show |
Axel, On Monday 16 July 2012 04:01 PM, Axel Lin wrote: > According to the datasheet, the voltage for twl6030ldo_ops is not linear for > all cases. Linear mapping is only for the selection code from > 00000001 to 00011000. > > Table 9. LDO Output Voltage Selection Code > CODE VOUT(V) COD VOUT(V) CODE VOUT(V) CODE VOUT(V) > 00000000 0 00001000 1.7 00010000 2.5 00011000 3.3 > 00000001 1.0 00001001 1.8 00010001 2.6 00011001 Reserved > 00000010 1.1 00001010 1.9 00010010 2.7 00011010 Reserved > 00000011 1.2 00001011 2.0 00010011 2.8 00011011 Reserved > 00000100 1.3 00001100 2.1 00010100 2.9 00011100 Reserved > 00000101 1.4 00001101 2.2 00010101 3.0 00011101 Reserved > 00000110 1.5 00001110 2.3 00010110 3.1 00011110 Reserved > 00000111 1.6 00001111 2.4 00010111 3.2 00011111 2.75 > > This patch implements the list_voltage callback based on above table. > > Signed-off-by: Axel Lin<axel.lin@gmail.com> Seems to work fine on my 4460 Panda. Without this fix.. [ 0.337341] V1V8: 1800 mV normal standby [ 0.338531] V2V1: 2100 mV normal standby [ 0.339813] VMMC: 1200 <--> 3000 mV at 3100 mV normal standby ^^^^^^^^ [ 0.341278] VPP: 1800 <--> 2500 mV at 2000 mV normal standby ^^^^^^^^^ [ 0.343505] VCXIO: 1800 mV normal standby [ 0.343597] VCXIO: supplied by V2V1 [ 0.345855] VDAC: 1800 mV normal standby [ 0.345947] VDAC: supplied by V2V1 [ 0.347717] VAUX2_6030: 1200 <--> 2800 mV at 1900 mV normal standby ^^^^^^^^ [ 0.349212] VAUX3_6030: 1000 <--> 3000 mV at 1300 mV normal standby ^^^^^^^^ And with the fix.. [ 0.337707] V1V8: 1800 mV normal standby [ 0.338897] V2V1: 2100 mV normal standby [ 0.340179] VMMC: 1200 <--> 3000 mV at 3000 mV normal standby [ 0.341674] VPP: 1800 <--> 2500 mV at 1900 mV normal standby [ 0.343383] VCXIO: 1800 mV normal standby [ 0.343475] VCXIO: supplied by V2V1 [ 0.345764] VDAC: 1800 mV normal standby [ 0.345825] VDAC: supplied by V2V1 [ 0.347656] VAUX2_6030: 1200 <--> 2800 mV at 1800 mV normal standby [ 0.349121] VAUX3_6030: 1000 <--> 3000 mV at 1200 mV normal standby Thanks for the patch. Tested-by: Rajendra Nayak <rnayak@ti.com> > --- > drivers/regulator/twl-regulator.c | 31 ++++++++++++++++++++++++------- > 1 file changed, 24 insertions(+), 7 deletions(-) > > diff --git a/drivers/regulator/twl-regulator.c b/drivers/regulator/twl-regulator.c > index de99b78..242fe90 100644 > --- a/drivers/regulator/twl-regulator.c > +++ b/drivers/regulator/twl-regulator.c > @@ -559,6 +559,27 @@ static struct regulator_ops twl6030coresmps_ops = { > .get_voltage = twl6030coresmps_get_voltage, > }; > > +static int twl6030ldo_list_voltage(struct regulator_dev *rdev, unsigned sel) > +{ > + struct twlreg_info *info = rdev_get_drvdata(rdev); > + > + switch (sel) { > + case 0: > + return 0; > + case 1 ... 24: > + /* Linear mapping from 00000001 to 00011000: > + * Absolute voltage value = 1.0 V + 0.1 V × (sel – 00000001) > + */ > + return (info->min_mV + 100 * (sel - 1)) * 1000; > + case 25 ... 30: > + return -EINVAL; > + case 31: > + return 2750000; > + default: > + return -EINVAL; > + } > +} > + > static int > twl6030ldo_set_voltage_sel(struct regulator_dev *rdev, unsigned selector) > { > @@ -577,7 +598,7 @@ static int twl6030ldo_get_voltage_sel(struct regulator_dev *rdev) > } > > static struct regulator_ops twl6030ldo_ops = { > - .list_voltage = regulator_list_voltage_linear, > + .list_voltage = twl6030ldo_list_voltage, > > .set_voltage_sel = twl6030ldo_set_voltage_sel, > .get_voltage_sel = twl6030ldo_get_voltage_sel, > @@ -906,12 +927,10 @@ static struct twlreg_info TWL6030_INFO_##label = { \ > .desc = { \ > .name = #label, \ > .id = TWL6030_REG_##label, \ > - .n_voltages = (max_mVolts - min_mVolts)/100 + 1, \ > + .n_voltages = 32, \ > .ops =&twl6030ldo_ops, \ > .type = REGULATOR_VOLTAGE, \ > .owner = THIS_MODULE, \ > - .min_uV = min_mVolts * 1000, \ > - .uV_step = 100 * 1000, \ > }, \ > } > > @@ -923,12 +942,10 @@ static struct twlreg_info TWL6025_INFO_##label = { \ > .desc = { \ > .name = #label, \ > .id = TWL6025_REG_##label, \ > - .n_voltages = ((max_mVolts - min_mVolts)/100) + 1, \ > + .n_voltages = 32, \ > .ops =&twl6030ldo_ops, \ > .type = REGULATOR_VOLTAGE, \ > .owner = THIS_MODULE, \ > - .min_uV = min_mVolts * 1000, \ > - .uV_step = 100 * 1000, \ > }, \ > } > -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
Sorry, I seemed to have messed up with the underlining. On Monday 16 July 2012 05:38 PM, Rajendra Nayak wrote: > [ 0.337341] V1V8: 1800 mV normal standby > [ 0.338531] V2V1: 2100 mV normal standby > [ 0.339813] VMMC: 1200 <--> 3000 mV at 3100 mV normal standby > ^^^^^^^^ I meant 3100 mV normal standby was wrong. > [ 0.341278] VPP: 1800 <--> 2500 mV at 2000 mV normal standby > ^^^^^^^^^ 2000 mV being wrong here. > [ 0.343505] VCXIO: 1800 mV normal standby > [ 0.343597] VCXIO: supplied by V2V1 > [ 0.345855] VDAC: 1800 mV normal standby > [ 0.345947] VDAC: supplied by V2V1 > [ 0.347717] VAUX2_6030: 1200 <--> 2800 mV at 1900 mV normal standby > ^^^^^^^^ 1900 mV here.. > [ 0.349212] VAUX3_6030: 1000 <--> 3000 mV at 1300 mV normal standby > ^^^^^^^^ and 1300 mV here. -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
On Mon, Jul 16, 2012 at 06:31:10PM +0800, Axel Lin wrote: > According to the datasheet, the voltage for twl6030ldo_ops is not linear for > all cases. Linear mapping is only for the selection code from > 00000001 to 00011000. Applied, thanks.
diff --git a/drivers/regulator/twl-regulator.c b/drivers/regulator/twl-regulator.c index de99b78..242fe90 100644 --- a/drivers/regulator/twl-regulator.c +++ b/drivers/regulator/twl-regulator.c @@ -559,6 +559,27 @@ static struct regulator_ops twl6030coresmps_ops = { .get_voltage = twl6030coresmps_get_voltage, }; +static int twl6030ldo_list_voltage(struct regulator_dev *rdev, unsigned sel) +{ + struct twlreg_info *info = rdev_get_drvdata(rdev); + + switch (sel) { + case 0: + return 0; + case 1 ... 24: + /* Linear mapping from 00000001 to 00011000: + * Absolute voltage value = 1.0 V + 0.1 V × (sel – 00000001) + */ + return (info->min_mV + 100 * (sel - 1)) * 1000; + case 25 ... 30: + return -EINVAL; + case 31: + return 2750000; + default: + return -EINVAL; + } +} + static int twl6030ldo_set_voltage_sel(struct regulator_dev *rdev, unsigned selector) { @@ -577,7 +598,7 @@ static int twl6030ldo_get_voltage_sel(struct regulator_dev *rdev) } static struct regulator_ops twl6030ldo_ops = { - .list_voltage = regulator_list_voltage_linear, + .list_voltage = twl6030ldo_list_voltage, .set_voltage_sel = twl6030ldo_set_voltage_sel, .get_voltage_sel = twl6030ldo_get_voltage_sel, @@ -906,12 +927,10 @@ static struct twlreg_info TWL6030_INFO_##label = { \ .desc = { \ .name = #label, \ .id = TWL6030_REG_##label, \ - .n_voltages = (max_mVolts - min_mVolts)/100 + 1, \ + .n_voltages = 32, \ .ops = &twl6030ldo_ops, \ .type = REGULATOR_VOLTAGE, \ .owner = THIS_MODULE, \ - .min_uV = min_mVolts * 1000, \ - .uV_step = 100 * 1000, \ }, \ } @@ -923,12 +942,10 @@ static struct twlreg_info TWL6025_INFO_##label = { \ .desc = { \ .name = #label, \ .id = TWL6025_REG_##label, \ - .n_voltages = ((max_mVolts - min_mVolts)/100) + 1, \ + .n_voltages = 32, \ .ops = &twl6030ldo_ops, \ .type = REGULATOR_VOLTAGE, \ .owner = THIS_MODULE, \ - .min_uV = min_mVolts * 1000, \ - .uV_step = 100 * 1000, \ }, \ }
According to the datasheet, the voltage for twl6030ldo_ops is not linear for all cases. Linear mapping is only for the selection code from 00000001 to 00011000. Table 9. LDO Output Voltage Selection Code CODE VOUT(V) COD VOUT(V) CODE VOUT(V) CODE VOUT(V) 00000000 0 00001000 1.7 00010000 2.5 00011000 3.3 00000001 1.0 00001001 1.8 00010001 2.6 00011001 Reserved 00000010 1.1 00001010 1.9 00010010 2.7 00011010 Reserved 00000011 1.2 00001011 2.0 00010011 2.8 00011011 Reserved 00000100 1.3 00001100 2.1 00010100 2.9 00011100 Reserved 00000101 1.4 00001101 2.2 00010101 3.0 00011101 Reserved 00000110 1.5 00001110 2.3 00010110 3.1 00011110 Reserved 00000111 1.6 00001111 2.4 00010111 3.2 00011111 2.75 This patch implements the list_voltage callback based on above table. Signed-off-by: Axel Lin <axel.lin@gmail.com> --- drivers/regulator/twl-regulator.c | 31 ++++++++++++++++++++++++------- 1 file changed, 24 insertions(+), 7 deletions(-)