[v3,1/2] dt-bindings: hwmon: pwm-fan: Document start from stopped state properties

Message ID 20241106185925.223736-1-marex@denx.de (mailing list archive)
State Accepted
Headers show
Series [v3,1/2] dt-bindings: hwmon: pwm-fan: Document start from stopped state properties | expand

Commit Message

Marek Vasut Nov. 6, 2024, 6:59 p.m. UTC
Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle
to spin up from a stopped state, and can be afterward throttled down to
lower PWM duty cycle. Introduce support for operating such fans which
need to start at higher PWM duty cycle first and can slow down next.

Document two new DT properties, "fan-stop-to-start-percent" and
"fan-stop-to-start-usec". The former describes the minimum percent
of fan RPM at which it will surely spin up from stopped state. This
value can be found in the fan datasheet and can be converted to PWM
duty cycle easily. The "fan-stop-to-start-usec" describes the minimum
time in microseconds for which the fan has to be set to stopped state
start RPM for the fan to surely spin up.

Signed-off-by: Marek Vasut <marex@denx.de>
---
Cc: Conor Dooley <conor+dt@kernel.org>
Cc: Guenter Roeck <linux@roeck-us.net>
Cc: Jean Delvare <jdelvare@suse.com>
Cc: Krzysztof Kozlowski <krzk+dt@kernel.org>
Cc: Rob Herring <robh@kernel.org>
Cc: devicetree@vger.kernel.org
Cc: linux-hwmon@vger.kernel.org
---
V2: - Rename fan-dead-stop-start-percent to fan-stop-to-start-percent
    - Rename fan-dead-stop-start-usec to fan-stop-to-start-us
V3: - Drop ref: /schemas/types.yaml#/definitions/uint32 from fan-stop-to-start-us
---
 Documentation/devicetree/bindings/hwmon/pwm-fan.yaml | 10 ++++++++++
 1 file changed, 10 insertions(+)

Comments

Conor Dooley Nov. 7, 2024, 5:24 p.m. UTC | #1
On Wed, Nov 06, 2024 at 07:59:04PM +0100, Marek Vasut wrote:
> Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle
> to spin up from a stopped state, and can be afterward throttled down to
> lower PWM duty cycle. Introduce support for operating such fans which
> need to start at higher PWM duty cycle first and can slow down next.
> 
> Document two new DT properties, "fan-stop-to-start-percent" and
> "fan-stop-to-start-usec". The former describes the minimum percent
> of fan RPM at which it will surely spin up from stopped state. This
> value can be found in the fan datasheet and can be converted to PWM
> duty cycle easily. The "fan-stop-to-start-usec" describes the minimum
> time in microseconds for which the fan has to be set to stopped state
> start RPM for the fan to surely spin up.
> 
> Signed-off-by: Marek Vasut <marex@denx.de>

Acked-by: Conor Dooley <conor.dooley@microchip.com>
Guenter Roeck Nov. 11, 2024, 7:32 p.m. UTC | #2
On Wed, Nov 06, 2024 at 07:59:04PM +0100, Marek Vasut wrote:
> Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle
> to spin up from a stopped state, and can be afterward throttled down to
> lower PWM duty cycle. Introduce support for operating such fans which
> need to start at higher PWM duty cycle first and can slow down next.
> 
> Document two new DT properties, "fan-stop-to-start-percent" and
> "fan-stop-to-start-usec". The former describes the minimum percent
> of fan RPM at which it will surely spin up from stopped state. This
> value can be found in the fan datasheet and can be converted to PWM
> duty cycle easily. The "fan-stop-to-start-usec" describes the minimum
> time in microseconds for which the fan has to be set to stopped state
> start RPM for the fan to surely spin up.
> 
> Signed-off-by: Marek Vasut <marex@denx.de>
> Acked-by: Conor Dooley <conor.dooley@microchip.com>

Applied.

Thanks,
Guenter
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/hwmon/pwm-fan.yaml b/Documentation/devicetree/bindings/hwmon/pwm-fan.yaml
index 4e5abf7580cc6..8b4ed5ee962fb 100644
--- a/Documentation/devicetree/bindings/hwmon/pwm-fan.yaml
+++ b/Documentation/devicetree/bindings/hwmon/pwm-fan.yaml
@@ -31,6 +31,16 @@  properties:
       it must be self resetting edge interrupts.
     maxItems: 1
 
+  fan-stop-to-start-percent:
+    description:
+      Minimum fan RPM in percent to start when stopped.
+    minimum: 0
+    maximum: 100
+
+  fan-stop-to-start-us:
+    description:
+      Time to wait in microseconds after start when stopped.
+
   pulses-per-revolution:
     description:
       Define the number of pulses per fan revolution for each tachometer