diff mbox series

[RFC,net-next,10/16] net: mvneta: implement pcs_inband_caps() method

Message ID E1tFrog-005xQY-LH@rmk-PC.armlinux.org.uk (mailing list archive)
State New
Headers show
Series net: add negotiation of in-band capabilities | expand

Commit Message

Russell King (Oracle) Nov. 26, 2024, 9:25 a.m. UTC
Report the PCS in-band capabilities to phylink for Marvell NETA
interfaces.

Signed-off-by: Russell King (Oracle) <rmk+kernel@armlinux.org.uk>
---
 drivers/net/ethernet/marvell/mvneta.c | 27 +++++++++++++++++----------
 1 file changed, 17 insertions(+), 10 deletions(-)

Comments

Andrew Lunn Nov. 26, 2024, 9:06 p.m. UTC | #1
On Tue, Nov 26, 2024 at 09:25:06AM +0000, Russell King (Oracle) wrote:
> Report the PCS in-band capabilities to phylink for Marvell NETA
> interfaces.
> 
> Signed-off-by: Russell King (Oracle) <rmk+kernel@armlinux.org.uk>

Reviewed-by: Andrew Lunn <andrew@lunn.ch>

    Andrew
diff mbox series

Patch

diff --git a/drivers/net/ethernet/marvell/mvneta.c b/drivers/net/ethernet/marvell/mvneta.c
index 1fb285fa0bdb..fe6261b81540 100644
--- a/drivers/net/ethernet/marvell/mvneta.c
+++ b/drivers/net/ethernet/marvell/mvneta.c
@@ -3960,20 +3960,27 @@  static struct mvneta_port *mvneta_pcs_to_port(struct phylink_pcs *pcs)
 	return container_of(pcs, struct mvneta_port, phylink_pcs);
 }
 
-static int mvneta_pcs_validate(struct phylink_pcs *pcs,
-			       unsigned long *supported,
-			       const struct phylink_link_state *state)
+static unsigned int mvneta_pcs_inband_caps(struct phylink_pcs *pcs,
+					   phy_interface_t interface)
 {
-	/* We only support QSGMII, SGMII, 802.3z and RGMII modes.
-	 * When in 802.3z mode, we must have AN enabled:
+	/* When operating in an 802.3z mode, we must have AN enabled:
 	 * "Bit 2 Field InBandAnEn In-band Auto-Negotiation enable. ...
 	 * When <PortType> = 1 (1000BASE-X) this field must be set to 1."
+	 * Therefore, inband is "required".
 	 */
-	if (phy_interface_mode_is_8023z(state->interface) &&
-	    !phylink_test(state->advertising, Autoneg))
-		return -EINVAL;
+	if (phy_interface_mode_is_8023z(interface))
+		return LINK_INBAND_ENABLE;
 
-	return 0;
+	/* QSGMII, SGMII and RGMII can be configured to use inband
+	 * signalling of the AN result. Indicate these as "possible".
+	 */
+	if (interface == PHY_INTERFACE_MODE_SGMII ||
+	    interface == PHY_INTERFACE_MODE_QSGMII ||
+	    phy_interface_mode_is_rgmii(interface))
+		return LINK_INBAND_DISABLE | LINK_INBAND_ENABLE;
+
+	/* For any other modes, indicate that inband is not supported. */
+	return LINK_INBAND_DISABLE;
 }
 
 static void mvneta_pcs_get_state(struct phylink_pcs *pcs,
@@ -4071,7 +4078,7 @@  static void mvneta_pcs_an_restart(struct phylink_pcs *pcs)
 }
 
 static const struct phylink_pcs_ops mvneta_phylink_pcs_ops = {
-	.pcs_validate = mvneta_pcs_validate,
+	.pcs_inband_caps = mvneta_pcs_inband_caps,
 	.pcs_get_state = mvneta_pcs_get_state,
 	.pcs_config = mvneta_pcs_config,
 	.pcs_an_restart = mvneta_pcs_an_restart,