diff mbox

hid: wacom: Intuos4 battery charging changes

Message ID 1372499833-7814-1-git-send-email-przemo@firszt.eu (mailing list archive)
State New, archived
Delegated to: Jiri Kosina
Headers show

Commit Message

Przemysław Firszt June 29, 2013, 9:57 a.m. UTC
Intuos4 WL is separately reporting power supply and battery
charging status - now hid-wacom is using that information.
Previously hid-wacom was wrongly treating "battery charging" bit
as "power supply connected". Now it should report battery charging,
battery discharging, battery full and power supply status.

Intuos4 WL sends reports when is in use (obvious) and when unplugging
power supply. If means that if the device is being charged, but it's not
being used it will never report "battery full". The same problem happens
after the device has been connected, but it's not in use - the
battery/ac status will be incorrect. Currently there is no mechanism to
ask the device to send a report containing battery/ac status.

Signed-off-by: Przemo Firszt <przemo@firszt.eu>
---
 drivers/hid/hid-wacom.c | 14 +++++++++++++-
 1 file changed, 13 insertions(+), 1 deletion(-)

Comments

Jiri Kosina July 1, 2013, 12:51 p.m. UTC | #1
On Sat, 29 Jun 2013, Przemo Firszt wrote:

> Intuos4 WL is separately reporting power supply and battery
> charging status - now hid-wacom is using that information.
> Previously hid-wacom was wrongly treating "battery charging" bit
> as "power supply connected". Now it should report battery charging,
> battery discharging, battery full and power supply status.
> 
> Intuos4 WL sends reports when is in use (obvious) and when unplugging
> power supply. If means that if the device is being charged, but it's not
> being used it will never report "battery full". The same problem happens
> after the device has been connected, but it's not in use - the
> battery/ac status will be incorrect. Currently there is no mechanism to
> ask the device to send a report containing battery/ac status.
> 
> Signed-off-by: Przemo Firszt <przemo@firszt.eu>

Applied, thanks Przemo.
diff mbox

Patch

diff --git a/drivers/hid/hid-wacom.c b/drivers/hid/hid-wacom.c
index a4a8bb0..60c75dc 100644
--- a/drivers/hid/hid-wacom.c
+++ b/drivers/hid/hid-wacom.c
@@ -46,6 +46,7 @@  struct wacom_data {
 	__u8 battery_capacity;
 	__u8 power_raw;
 	__u8 ps_connected;
+	__u8 bat_charging;
 	struct power_supply battery;
 	struct power_supply ac;
 	__u8 led_selector;
@@ -62,6 +63,7 @@  static enum power_supply_property wacom_battery_props[] = {
 	POWER_SUPPLY_PROP_PRESENT,
 	POWER_SUPPLY_PROP_CAPACITY,
 	POWER_SUPPLY_PROP_SCOPE,
+	POWER_SUPPLY_PROP_STATUS,
 };
 
 static enum power_supply_property wacom_ac_props[] = {
@@ -287,6 +289,15 @@  static int wacom_battery_get_property(struct power_supply *psy,
 	case POWER_SUPPLY_PROP_CAPACITY:
 		val->intval = wdata->battery_capacity;
 		break;
+	case POWER_SUPPLY_PROP_STATUS:
+		if (wdata->bat_charging)
+			val->intval = POWER_SUPPLY_STATUS_CHARGING;
+		else
+			if (wdata->battery_capacity == 100 && wdata->ps_connected)
+				val->intval = POWER_SUPPLY_STATUS_FULL;
+			else
+				val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+		break;
 	default:
 		ret = -EINVAL;
 		break;
@@ -727,7 +738,8 @@  static int wacom_raw_event(struct hid_device *hdev, struct hid_report *report,
 			if (power_raw != wdata->power_raw) {
 				wdata->power_raw = power_raw;
 				wdata->battery_capacity = batcap_i4[power_raw & 0x07];
-				wdata->ps_connected = power_raw & 0x08;
+				wdata->bat_charging = (power_raw & 0x08) ? 1 : 0;
+				wdata->ps_connected = (power_raw & 0x10) ? 1 : 0;
 			}
 
 			break;