diff mbox

[RFC,08/14] KVM-test: Add a subtest of nic promisc

Message ID 20100720013558.2212.32065.stgit@z (mailing list archive)
State New, archived
Headers show

Commit Message

Amos Kong July 20, 2010, 1:35 a.m. UTC
None
diff mbox

Patch

diff --git a/client/tests/kvm/tests/nic_promisc.py b/client/tests/kvm/tests/nic_promisc.py
new file mode 100644
index 0000000..9a0c979
--- /dev/null
+++ b/client/tests/kvm/tests/nic_promisc.py
@@ -0,0 +1,87 @@ 
+import logging, commands
+from autotest_lib.client.common_lib import error
+import kvm_utils, kvm_test_utils, kvm_net_utils
+
+def run_nic_promisc(test, params, env):
+    """
+    Test nic driver in promisc mode:
+
+    1) Boot up a guest
+    2) Repeatedly enable/disable promiscuous mode in guest
+    3) TCP data transmission from host to guest, and from guest to host,
+       with 1/1460/65000/100000000 bytes payloads
+    4) Clean temporary files
+    5) Stop enable/disable promiscuous mode change
+
+    @param test: kvm test object
+    @param params: Dictionary with the test parameters
+    @param env: Dictionary with test environment
+    """
+    timeout = int(params.get("login_timeout", 360))
+    vm = kvm_test_utils.get_living_vm(env, params.get("main_vm"))
+    session = kvm_test_utils.wait_for_login(vm, timeout=timeout)
+    logging.info("Trying to log into guest '%s' by serial", vm.name)
+    session2 = kvm_utils.wait_for(lambda: vm.serial_login(),
+                                  timeout, 0, step=2)
+    if not session2:
+        raise error.TestFail("Could not log into guest '%s'" % vm.name)
+
+    def compare(filename):
+        cmd = "md5sum %s" % filename
+        s1, ret_host = commands.getstatusoutput(cmd)
+        s2, ret_guest = session.get_command_status_output(cmd)
+        if s1 != 0 or s2 != 0:
+            logging.debug("ret_host:%s, ret_guest:%s" % (ret_host, ret_guest))
+            logging.error("Could not get md5, cmd:%s" % cmd)
+            return False
+        if ret_host.strip() != ret_guest.strip():
+            logging.debug("ret_host :%s, ret_guest:%s" % (ret_host, ret_guest))
+            logging.error("Files' md5sum mismatch" % (receiver))
+            return False
+        return True
+
+    ethname = kvm_net_utils.get_linux_ifname(session, vm.get_macaddr(0))
+    set_promisc_cmd = "ip link set %s promisc on; sleep 0.01;" % ethname
+    set_promisc_cmd += "ip link set %s promisc off; sleep 0.01" % ethname
+    logging.info("Set promisc change repeatedly in guest")
+    session2.sendline("while true; do %s; done" % set_promisc_cmd)
+
+    dd_cmd = "dd if=/dev/urandom of=%s bs=%d count=1"
+    filename = "/tmp/nic_promisc_file"
+    file_size = params.get("file_size", "1, 1460, 65000, 100000000").split(",")
+    try:
+        for size in file_size:
+            logging.info("Create %s bytes file on host" % size)
+            s, o = commands.getstatusoutput(dd_cmd % (filename, int(size)))
+            if s != 0:
+                logging.debug("Output: %s"% o)
+                raise error.TestFail("Create file on host failed")
+
+            logging.info("Transfer file from host to guest")
+            if not vm.copy_files_to(filename, filename):
+                raise error.TestFail("File transfer failed")
+            if not compare(filename):
+                raise error.TestFail("Compare file failed")
+
+            logging.info("Create %s bytes file on guest" % size)
+            if session.get_command_status(dd_cmd % (filename, int(size)),
+                                                    timeout=100) != 0:
+                raise error.TestFail("Create file on guest failed")
+
+            logging.info("Transfer file from guest to host")
+            if not vm.copy_files_from(filename, filename):
+                raise error.TestFail("File transfer failed")
+            if not compare(filename):
+                raise error.TestFail("Compare file failed")
+
+            logging.info("Clean temporal files")
+            cmd = "rm -f %s" % filename
+            s1, o = commands.getstatusoutput(cmd)
+            s2 = session.get_command_status(cmd)
+            if s1 != 0 or s2 != 0:
+                raise error.TestError("Fail to clean temporal files")
+    finally:
+        logging.info("Restore the %s to the nonpromisc mode" % ethname)
+        session2.close()
+        session.get_command_status("ip link set %s promisc off" % ethname)
+        session.close()
diff --git a/client/tests/kvm/tests_base.cfg.sample b/client/tests/kvm/tests_base.cfg.sample
index 03d15c0..9e2b9a0 100644
--- a/client/tests/kvm/tests_base.cfg.sample
+++ b/client/tests/kvm/tests_base.cfg.sample
@@ -370,6 +370,10 @@  variants:
         scp_timeout = 300
         thread_num = 10
 
+    - nic_promisc:  install setup unattended_install.cdrom
+        type = nic_promisc
+        file_size = 1, 1460, 65000, 100000000
+
     - physical_resources_check: install setup unattended_install.cdrom
         type = physical_resources_check
         catch_uuid_cmd = dmidecode | awk -F: '/UUID/ {print $2}'
@@ -1046,7 +1050,7 @@  variants:
 
     # Windows section
     - @Windows:
-        no autotest linux_s3 vlan_tag ioquit unattended_install.(url|nfs|remote_ks) jumbo file_transfer nicdriver_unload
+        no autotest linux_s3 vlan_tag ioquit unattended_install.(url|nfs|remote_ks) jumbo file_transfer nicdriver_unload nic_promisc
         shutdown_command = shutdown /s /f /t 0
         reboot_command = shutdown /r /f /t 0
         status_test_command = echo %errorlevel%