[2/6] thermal: sysfs-api.txt - document passive attribute for thermal zones

Message ID 1251303445-25317-3-git-send-email-elendil@planet.nl (mailing list archive)
State RFC, archived
Headers show

Commit Message

Frans Pop Aug. 26, 2009, 4:17 p.m. UTC
Signed-off-by: Frans Pop <elendil@planet.nl>
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Sujith Thomas <sujith.thomas@intel.com>
Cc: Matthew Garrett <mjg59@srcf.ucam.org>

--
To unsubscribe from this list: send the line "unsubscribe linux-acpi" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Comments

Zhang, Rui Aug. 31, 2009, 8:18 a.m. UTC | #1
On Thu, 2009-08-27 at 00:17 +0800, Frans Pop wrote:
> Signed-off-by: Frans Pop <elendil@planet.nl>
> Cc: Zhang Rui <rui.zhang@intel.com>
> Cc: Sujith Thomas <sujith.thomas@intel.com>
> Cc: Matthew Garrett <mjg59@srcf.ucam.org>
> 
> diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
> index 895337f..2a036eb 100644
> --- a/Documentation/thermal/sysfs-api.txt
> +++ b/Documentation/thermal/sysfs-api.txt
> @@ -3,7 +3,7 @@ Generic Thermal Sysfs driver How To
>  
>  Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
>  
> -Updated: 2 January 2008
> +Updated: 21 August 2009
>  
>  Copyright (c)  2008 Intel Corporation
>  
> @@ -199,6 +199,15 @@ cdev[0-*]_trip_point
>  	point.
>  	RO, Optional
>  
> +passive
> +	Attribute is only present for zones which do not have a passive
> +	cooling policy (_PSV) defined in ACPI.

We should not involve any platform specific stuff in this documentation.
how about "Attribute is only present for zones in which the passive
cooling policy is not supported by native thermal driver"

>  Default is zero and can be
> +	set to a temperature (in millidegrees) to enable a passive trip
> +	point for the zone. Activation is done by polling with an interval
> +	of 1 second.
> +	Unit: millidegrees Celsius
> +	RW, Optional
> +
>  *****************************
>  * Cooling device attributes *
>  *****************************
> @@ -230,8 +239,9 @@ thermal_zone_device (thermal_zone1) with 4 trip points in all.
>  It has one processor and one fan, which are both registered as
>  thermal_cooling_device.
>  
> -If the processor is listed in _PSL method, and the fan is listed in _AL0
> -method, the sys I/F structure will be built like this:
> +If the processor is listed in _PSL method, the fan is listed in _AL0
> +method, and the zone has a _PSV method, the sys I/F structure will be
> +built like this:
>  
For an ACPI thermal zone, supporting passive cooling means that both
_PSL and _PSV are available.
so I don't think we need to change this. :)

thanks,
rui
>  /sys/class/thermal:
>  

--
To unsubscribe from this list: send the line "unsubscribe linux-acpi" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
diff mbox

Patch

diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index 895337f..2a036eb 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -3,7 +3,7 @@  Generic Thermal Sysfs driver How To
 
 Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
 
-Updated: 2 January 2008
+Updated: 21 August 2009
 
 Copyright (c)  2008 Intel Corporation
 
@@ -199,6 +199,15 @@  cdev[0-*]_trip_point
 	point.
 	RO, Optional
 
+passive
+	Attribute is only present for zones which do not have a passive
+	cooling policy (_PSV) defined in ACPI. Default is zero and can be
+	set to a temperature (in millidegrees) to enable a passive trip
+	point for the zone. Activation is done by polling with an interval
+	of 1 second.
+	Unit: millidegrees Celsius
+	RW, Optional
+
 *****************************
 * Cooling device attributes *
 *****************************
@@ -230,8 +239,9 @@  thermal_zone_device (thermal_zone1) with 4 trip points in all.
 It has one processor and one fan, which are both registered as
 thermal_cooling_device.
 
-If the processor is listed in _PSL method, and the fan is listed in _AL0
-method, the sys I/F structure will be built like this:
+If the processor is listed in _PSL method, the fan is listed in _AL0
+method, and the zone has a _PSV method, the sys I/F structure will be
+built like this:
 
 /sys/class/thermal: