@@ -46,7 +46,7 @@ MODULE_LICENSE("GPL");
* a certain cooling device on a certain trip point
* in a certain thermal zone
*/
-struct thermal_cooling_device_instance {
+struct thermal_instance {
int id;
char name[THERMAL_NAME_LENGTH];
struct thermal_zone_device *tz;
@@ -429,10 +429,10 @@ static ssize_t
thermal_cooling_device_trip_point_show(struct device *dev,
struct device_attribute *attr, char *buf)
{
- struct thermal_cooling_device_instance *instance;
+ struct thermal_instance *instance;
instance =
- container_of(attr, struct thermal_cooling_device_instance, attr);
+ container_of(attr, struct thermal_instance, attr);
if (instance->trip == THERMAL_TRIPS_NONE)
return sprintf(buf, "-1\n");
@@ -727,7 +727,7 @@ static void thermal_zone_device_passive(struct thermal_zone_device *tz,
int temp, int trip_temp, int trip)
{
int trend = 0;
- struct thermal_cooling_device_instance *instance;
+ struct thermal_instance *instance;
struct thermal_cooling_device *cdev;
long state, max_state;
@@ -812,8 +812,8 @@ int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
struct thermal_cooling_device *cdev,
long upper, long lower)
{
- struct thermal_cooling_device_instance *dev;
- struct thermal_cooling_device_instance *pos;
+ struct thermal_instance *dev;
+ struct thermal_instance *pos;
struct thermal_zone_device *pos1;
struct thermal_cooling_device *pos2;
unsigned long max_state;
@@ -844,7 +844,7 @@ int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
return -EINVAL;
dev =
- kzalloc(sizeof(struct thermal_cooling_device_instance), GFP_KERNEL);
+ kzalloc(sizeof(struct thermal_instance), GFP_KERNEL);
if (!dev)
return -ENOMEM;
dev->tz = tz;
@@ -909,7 +909,7 @@ int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
int trip,
struct thermal_cooling_device *cdev)
{
- struct thermal_cooling_device_instance *pos, *next;
+ struct thermal_instance *pos, *next;
mutex_lock(&tz->lock);
list_for_each_entry_safe(pos, next, &tz->cooling_devices, node) {
@@ -1095,7 +1095,7 @@ EXPORT_SYMBOL(thermal_cooling_device_unregister);
static void thermal_zone_trip_update(struct thermal_zone_device *tz,
int trip, long temp)
{
- struct thermal_cooling_device_instance *instance;
+ struct thermal_instance *instance;
struct thermal_cooling_device *cdev = NULL;
unsigned long cur_state, max_state;
long trip_temp;
This struct is used to describe the behavior for a thermal cooling device on a certain trip point for a certain thremal zone. thermal_cooling_device_instance is not accurate, as a cooling device can be used for more than one trip point in one thermal zone device. Signed-off-by: Zhang Rui <rui.zhang@intel.com> --- drivers/thermal/thermal_sys.c | 18 +++++++++--------- 1 file changed, 9 insertions(+), 9 deletions(-)