Message ID | 1344516365-7230-13-git-send-email-durgadoss.r@intel.com (mailing list archive) |
---|---|
State | New, archived |
Headers | show |
hello, On Thu, Aug 09, 2012 at 06:16:04PM +0530, Durgadoss R wrote: > This patch adds documentation for the structure > thermal_zone_params, and also shows an example of > how to populate them. Just a reminder, I believe you should also expose some documentation about the new functions exported in this series. > > Signed-off-by: Durgadoss R <durgadoss.r@intel.com> > --- > Documentation/thermal/sysfs-api.txt | 30 ++++++++++++++++++++++++++++++ > 1 file changed, 30 insertions(+) > > diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt > index ca1a1a3..669720c 100644 > --- a/Documentation/thermal/sysfs-api.txt > +++ b/Documentation/thermal/sysfs-api.txt > @@ -112,6 +112,36 @@ temperature) and throttle appropriate devices. > trip: indicates which trip point the cooling devices is associated with > in this thermal zone. > > +1.4 Thermal Zone Parameters > +1.4.1 struct thermal_zone_params > + This structure defines the platform level parameters for a thermal zone. > + This data, for each thermal zone should come from the platform layer. > + This is an optional feature where some platforms can choose not to > + provide this data. > +1.4.2 struct thermal_zone_params attributes > + .thermal_zone_name: Name of the thermal zone, for which these parameters > + are being defined. > + .num_cdevs: Number of cooling devices associated with this > + thermal zone. > + .cdevs_name: Names of the cooling devices associated with this > + thermal zone. > + .weights: This parameter defines the 'influence' of a particular cooling > + device on this thermal zone, on a percentage scale. The sum of > + all these weights cannot exceed 100. The order of values in > + this array should match with that of the cdevs_name. > + .trip_mask: This is a bit mask that gives the binding relation between > + this thermal zone and cdev, for a particular trip point. > + If nth bit is set, then the cdev and thermal zone are bound > + for trip point n. > +1.4.3 An example thermal_zone_params structure > + struct thermal_zone_params tzp = { > + .thermal_zone_name = "CPU", > + .num_cdevs = 2, > + .cdevs_name = {"CPU", "Memory"}, > + .weights = {70, 30}, > + .trip_mask = {0x0F, 0x08}, > + }; > + > 2. sysfs attributes structure > > RO read only value > -- > 1.7.9.5 > -- To unsubscribe from this list: send the line "unsubscribe linux-acpi" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
> -----Original Message----- > From: linux-acpi-owner@vger.kernel.org [mailto:linux-acpi- > owner@vger.kernel.org] On Behalf Of Eduardo Valentin > Sent: Tuesday, August 21, 2012 11:09 AM > To: R, Durgadoss > Cc: lenb@kernel.org; Zhang, Rui; rjw@sisk.pl; linux-acpi@vger.kernel.org; > linux-pm@vger.kernel.org; eduardo.valentin@ti.com; > amit.kachhap@linaro.org; wni@nvidia.com > Subject: Re: [PATCH 12/13] Thermal: Add documentation for platform layer > data > > hello, > > On Thu, Aug 09, 2012 at 06:16:04PM +0530, Durgadoss R wrote: > > This patch adds documentation for the structure > > thermal_zone_params, and also shows an example of > > how to populate them. > > Just a reminder, I believe you should also expose some documentation > about > the new functions exported in this series. Thanks for the catch :-) Will add in v2. > > > > > Signed-off-by: Durgadoss R <durgadoss.r@intel.com> > > --- > > Documentation/thermal/sysfs-api.txt | 30 > ++++++++++++++++++++++++++++++ > > 1 file changed, 30 insertions(+) > > > > diff --git a/Documentation/thermal/sysfs-api.txt > b/Documentation/thermal/sysfs-api.txt > > index ca1a1a3..669720c 100644 > > --- a/Documentation/thermal/sysfs-api.txt > > +++ b/Documentation/thermal/sysfs-api.txt > > @@ -112,6 +112,36 @@ temperature) and throttle appropriate devices. > > trip: indicates which trip point the cooling devices is associated with > > in this thermal zone. > > > > +1.4 Thermal Zone Parameters > > +1.4.1 struct thermal_zone_params > > + This structure defines the platform level parameters for a thermal zone. > > + This data, for each thermal zone should come from the platform layer. > > + This is an optional feature where some platforms can choose not to > > + provide this data. > > +1.4.2 struct thermal_zone_params attributes > > + .thermal_zone_name: Name of the thermal zone, for which these > parameters > > + are being defined. > > + .num_cdevs: Number of cooling devices associated with this > > + thermal zone. > > + .cdevs_name: Names of the cooling devices associated with this > > + thermal zone. > > + .weights: This parameter defines the 'influence' of a particular cooling > > + device on this thermal zone, on a percentage scale. The sum of > > + all these weights cannot exceed 100. The order of values in > > + this array should match with that of the cdevs_name. > > + .trip_mask: This is a bit mask that gives the binding relation between > > + this thermal zone and cdev, for a particular trip point. > > + If nth bit is set, then the cdev and thermal zone are bound > > + for trip point n. > > +1.4.3 An example thermal_zone_params structure > > + struct thermal_zone_params tzp = { > > + .thermal_zone_name = "CPU", > > + .num_cdevs = 2, > > + .cdevs_name = {"CPU", "Memory"}, > > + .weights = {70, 30}, > > + .trip_mask = {0x0F, 0x08}, > > + }; > > + > > 2. sysfs attributes structure > > > > RO read only value > > -- > > 1.7.9.5 > > > -- > To unsubscribe from this list: send the line "unsubscribe linux-acpi" in > the body of a message to majordomo@vger.kernel.org > More majordomo info at http://vger.kernel.org/majordomo-info.html -- To unsubscribe from this list: send the line "unsubscribe linux-acpi" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index ca1a1a3..669720c 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt @@ -112,6 +112,36 @@ temperature) and throttle appropriate devices. trip: indicates which trip point the cooling devices is associated with in this thermal zone. +1.4 Thermal Zone Parameters +1.4.1 struct thermal_zone_params + This structure defines the platform level parameters for a thermal zone. + This data, for each thermal zone should come from the platform layer. + This is an optional feature where some platforms can choose not to + provide this data. +1.4.2 struct thermal_zone_params attributes + .thermal_zone_name: Name of the thermal zone, for which these parameters + are being defined. + .num_cdevs: Number of cooling devices associated with this + thermal zone. + .cdevs_name: Names of the cooling devices associated with this + thermal zone. + .weights: This parameter defines the 'influence' of a particular cooling + device on this thermal zone, on a percentage scale. The sum of + all these weights cannot exceed 100. The order of values in + this array should match with that of the cdevs_name. + .trip_mask: This is a bit mask that gives the binding relation between + this thermal zone and cdev, for a particular trip point. + If nth bit is set, then the cdev and thermal zone are bound + for trip point n. +1.4.3 An example thermal_zone_params structure + struct thermal_zone_params tzp = { + .thermal_zone_name = "CPU", + .num_cdevs = 2, + .cdevs_name = {"CPU", "Memory"}, + .weights = {70, 30}, + .trip_mask = {0x0F, 0x08}, + }; + 2. sysfs attributes structure RO read only value
This patch adds documentation for the structure thermal_zone_params, and also shows an example of how to populate them. Signed-off-by: Durgadoss R <durgadoss.r@intel.com> --- Documentation/thermal/sysfs-api.txt | 30 ++++++++++++++++++++++++++++++ 1 file changed, 30 insertions(+)