@@ -353,10 +353,20 @@ power[1-*]_average Average power use
Unit: microWatt
RO
-power[1-*]_average_interval Power use averaging interval
+power[1-*]_average_interval Power use averaging interval. A poll
+ notification is sent to this file if the
+ hardware changes the averaging interval.
Unit: milliseconds
RW
+power[1-*]_average_interval_max Maximum power use averaging interval
+ Unit: milliseconds
+ RO
+
+power[1-*]_average_interval_min Minimum power use averaging interval
+ Unit: milliseconds
+ RO
+
power[1-*]_average_highest Historical average maximum power use
Unit: microWatt
RO
@@ -365,6 +375,18 @@ power[1-*]_average_lowest Historical average minimum power use
Unit: microWatt
RO
+power[1-*]_average_max A poll notification is sent to
+ power[1-*]_average when power use
+ rises above this value.
+ Unit: microWatt
+ RW
+
+power[1-*]_average_min A poll notification is sent to
+ power[1-*]_average when power use
+ sinks below this value.
+ Unit: microWatt
+ RW
+
power[1-*]_input Instantaneous power use
Unit: microWatt
RO
@@ -381,6 +403,42 @@ power[1-*]_reset_history Reset input_highest, input_lowest,
average_highest and average_lowest.
WO
+power[1-*]_accuracy Accuracy of the power meter.
+ Unit: Percent
+ RO
+
+power[1-*]_alarm 1 if the system is drawing more power than the
+ cap allows; 0 otherwise. A poll notification is
+ sent to this file if the power use exceeds the
+ cap. The action that is taken when this event
+ happens is undefined--it is possible that the
+ hardware will reduce performance to cut the
+ power use, but it is also possible that the
+ system designer expects the OS to try to
+ reduce power consumption. Contact your
+ machine's vendor to find out which.
+ RO
+
+power[1-*]_cap If power use rises above this limit, the
+ system should take action to reduce power use.
+ A poll notification is sent to this file if the
+ cap is changed by the hardware.
+ Unit: microWatt
+ RW
+
+power[1-*]_cap_hyst Margin of hysteresis built around capping and
+ notification.
+ Unit: microWatt
+ RW
+
+power[1-*]_cap_max Maximum cap that can be set.
+ Unit: microWatt
+ RO
+
+power[1-*]_cap_min Minimum cap that can be set.
+ Unit: microWatt
+ RO
+
**********
* Energy *
**********
Augment the documentation of the hwmon sysfs API to accomodate ACPI power meters. Signed-off-by: Darrick J. Wong <djwong@us.ibm.com> --- Documentation/hwmon/sysfs-interface | 60 ++++++++++++++++++++++++++++++++++- 1 files changed, 59 insertions(+), 1 deletions(-) -- To unsubscribe from this list: send the line "unsubscribe linux-acpi" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html