Message ID | 20231129134004.3642121-3-jbrunet@baylibre.com (mailing list archive) |
---|---|
State | Superseded |
Headers | show |
Series | pwm: meson: dt-bindings fixup | expand |
Hi, On 29/11/2023 14:39, Jerome Brunet wrote: > Add a new compatible for the pwm found in the meson8 to sm1 Amlogic SoCs, > dealing with clocks differently. This does not enable new HW. It is meant > to fix a bad DT ABI for the currently supported HW. > > The original clock bindings describe which input the PWM channel > multiplexer should pick among its possible parents, which are > hard-coded in the driver. As such, it is a setting tied to the driver > implementation and does not describe the HW. > > The new bindings introduce here describe the clocks input of the PWM block > as they exist. > > The old compatible is deprecated but kept to maintain ABI compatibility. > > The SoC specific compatibles introduced match the SoC families supported > by the original bindings. > > Signed-off-by: Jerome Brunet <jbrunet@baylibre.com> > --- > .../devicetree/bindings/pwm/pwm-amlogic.yaml | 52 ++++++++++++++++--- > 1 file changed, 46 insertions(+), 6 deletions(-) > > diff --git a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml > index 387976ed36d5..eece390114a3 100644 > --- a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml > +++ b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml > @@ -21,23 +21,35 @@ properties: > - amlogic,meson-g12a-ee-pwm > - amlogic,meson-g12a-ao-pwm-ab > - amlogic,meson-g12a-ao-pwm-cd > - - amlogic,meson-s4-pwm > + deprecated: true > - items: > - const: amlogic,meson-gx-pwm > - const: amlogic,meson-gxbb-pwm > + deprecated: true > - items: > - const: amlogic,meson-gx-ao-pwm > - const: amlogic,meson-gxbb-ao-pwm > + deprecated: true > - items: > - const: amlogic,meson8-pwm > - const: amlogic,meson8b-pwm > + deprecated: true I think deprecated should be moved in a third patch > + - const: amlogic,meson8-pwm-v2 > + - items: > + - enum: > + - amlogic,meson8b-pwm-v2 > + - amlogic,meson-gxbb-pwm-v2 > + - amlogic,meson-axg-pwm-v2 > + - amlogic,meson-g12-pwm-v2 > + - const: amlogic,meson8-pwm-v2 > + - const: amlogic,meson-s4-pwm > > reg: > maxItems: 1 > > clocks: > minItems: 1 > - maxItems: 2 > + maxItems: 4 > > clock-names: > minItems: 1 > @@ -58,7 +70,6 @@ allOf: > compatible: > contains: > enum: > - - amlogic,meson8-pwm > - amlogic,meson8b-pwm > - amlogic,meson-gxbb-pwm > - amlogic,meson-gxbb-ao-pwm > @@ -67,14 +78,15 @@ allOf: > - amlogic,meson-g12a-ee-pwm > - amlogic,meson-g12a-ao-pwm-ab > - amlogic,meson-g12a-ao-pwm-cd > - - amlogic,meson-gx-pwm > - - amlogic,meson-gx-ao-pwm I don't understand why those entries are removed > then: > - # Historic bindings tied to the driver implementation > + # Obsolete historic bindings tied to the driver implementation > # The clocks provided here are meant to be matched with the input > # known (hard-coded) in the driver and used to select pwm clock > # source. Currently, the linux driver ignores this. > + # This is kept to maintain ABI backward compatibility. Same here, this should go in a third patch > properties: > + clocks: > + maxItems: 2 > clock-names: > oneOf: > - items: > @@ -83,6 +95,27 @@ allOf: > - const: clkin0 > - const: clkin1 > > + # Newer binding where clock describe the actual clock inputs of the pwm > + # block. These are necessary but some inputs may be grounded. > + - if: > + properties: > + compatible: > + contains: > + enum: > + - amlogic,meson8-pwm-v2 > + then: > + properties: > + clocks: > + minItems: 1 > + items: > + - description: input clock 0 of the pwm block > + - description: input clock 1 of the pwm block > + - description: input clock 2 of the pwm block > + - description: input clock 3 of the pwm block > + clock-names: false > + required: > + - clocks > + > # Newer IP block take a single input per channel, instead of 4 inputs > # for both channels > - if: > @@ -112,6 +145,13 @@ examples: > clock-names = "clkin0", "clkin1"; > #pwm-cells = <3>; > }; > + - | > + pwm@2000 { > + compatible = "amlogic,meson8-pwm-v2"; > + reg = <0x1000 0x10>; > + clocks = <&xtal>, <0>, <&fdiv4>, <&fdiv5>; > + #pwm-cells = <3>; > + }; > - | > pwm@1000 { > compatible = "amlogic,meson-s4-pwm"; Neil
On Wed 29 Nov 2023 at 17:20, Neil Armstrong <neil.armstrong@linaro.org> wrote: > Hi, > > On 29/11/2023 14:39, Jerome Brunet wrote: >> Add a new compatible for the pwm found in the meson8 to sm1 Amlogic SoCs, >> dealing with clocks differently. This does not enable new HW. It is meant >> to fix a bad DT ABI for the currently supported HW. >> The original clock bindings describe which input the PWM channel >> multiplexer should pick among its possible parents, which are >> hard-coded in the driver. As such, it is a setting tied to the driver >> implementation and does not describe the HW. >> The new bindings introduce here describe the clocks input of the PWM >> block >> as they exist. >> The old compatible is deprecated but kept to maintain ABI compatibility. >> The SoC specific compatibles introduced match the SoC families supported >> by the original bindings. >> Signed-off-by: Jerome Brunet <jbrunet@baylibre.com> >> --- >> .../devicetree/bindings/pwm/pwm-amlogic.yaml | 52 ++++++++++++++++--- >> 1 file changed, 46 insertions(+), 6 deletions(-) >> diff --git a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >> b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >> index 387976ed36d5..eece390114a3 100644 >> --- a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >> +++ b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >> @@ -21,23 +21,35 @@ properties: >> - amlogic,meson-g12a-ee-pwm >> - amlogic,meson-g12a-ao-pwm-ab >> - amlogic,meson-g12a-ao-pwm-cd >> - - amlogic,meson-s4-pwm >> + deprecated: true >> - items: >> - const: amlogic,meson-gx-pwm >> - const: amlogic,meson-gxbb-pwm >> + deprecated: true >> - items: >> - const: amlogic,meson-gx-ao-pwm >> - const: amlogic,meson-gxbb-ao-pwm >> + deprecated: true >> - items: >> - const: amlogic,meson8-pwm >> - const: amlogic,meson8b-pwm >> + deprecated: true > > I think deprecated should be moved in a third patch The complain on v2 was that it was not clear the new binding was making the old one obsolete. It looked to me that the deprecation old bindings needed to go together with the introduction of the new. I don't mind one way or the other Is there a rule somewhere about this ? > >> + - const: amlogic,meson8-pwm-v2 >> + - items: >> + - enum: >> + - amlogic,meson8b-pwm-v2 >> + - amlogic,meson-gxbb-pwm-v2 >> + - amlogic,meson-axg-pwm-v2 >> + - amlogic,meson-g12-pwm-v2 >> + - const: amlogic,meson8-pwm-v2 >> + - const: amlogic,meson-s4-pwm >> reg: >> maxItems: 1 >> clocks: >> minItems: 1 >> - maxItems: 2 >> + maxItems: 4 >> clock-names: >> minItems: 1 >> @@ -58,7 +70,6 @@ allOf: >> compatible: >> contains: >> enum: >> - - amlogic,meson8-pwm >> - amlogic,meson8b-pwm >> - amlogic,meson-gxbb-pwm >> - amlogic,meson-gxbb-ao-pwm >> @@ -67,14 +78,15 @@ allOf: >> - amlogic,meson-g12a-ee-pwm >> - amlogic,meson-g12a-ao-pwm-ab >> - amlogic,meson-g12a-ao-pwm-cd >> - - amlogic,meson-gx-pwm >> - - amlogic,meson-gx-ao-pwm > > I don't understand why those entries are removed It's a mistake. It should not have been added to begin with in the first patch. "amlogic,meson-gx-*" must go along with "amlogic,meson-gxbb-*" so it matches correctly without it. I'll fix it > >> then: >> - # Historic bindings tied to the driver implementation >> + # Obsolete historic bindings tied to the driver implementation >> # The clocks provided here are meant to be matched with the input >> # known (hard-coded) in the driver and used to select pwm clock >> # source. Currently, the linux driver ignores this. >> + # This is kept to maintain ABI backward compatibility. > > Same here, this should go in a third patch > >> properties: >> + clocks: >> + maxItems: 2 >> clock-names: >> oneOf: >> - items: >> @@ -83,6 +95,27 @@ allOf: >> - const: clkin0 >> - const: clkin1 >> + # Newer binding where clock describe the actual clock inputs of the >> pwm >> + # block. These are necessary but some inputs may be grounded. >> + - if: >> + properties: >> + compatible: >> + contains: >> + enum: >> + - amlogic,meson8-pwm-v2 >> + then: >> + properties: >> + clocks: >> + minItems: 1 >> + items: >> + - description: input clock 0 of the pwm block >> + - description: input clock 1 of the pwm block >> + - description: input clock 2 of the pwm block >> + - description: input clock 3 of the pwm block >> + clock-names: false >> + required: >> + - clocks >> + >> # Newer IP block take a single input per channel, instead of 4 inputs >> # for both channels >> - if: >> @@ -112,6 +145,13 @@ examples: >> clock-names = "clkin0", "clkin1"; >> #pwm-cells = <3>; >> }; >> + - | >> + pwm@2000 { >> + compatible = "amlogic,meson8-pwm-v2"; >> + reg = <0x1000 0x10>; >> + clocks = <&xtal>, <0>, <&fdiv4>, <&fdiv5>; >> + #pwm-cells = <3>; >> + }; >> - | >> pwm@1000 { >> compatible = "amlogic,meson-s4-pwm"; > > Neil
Hi, On 29/11/2023 17:26, Jerome Brunet wrote: > > On Wed 29 Nov 2023 at 17:20, Neil Armstrong <neil.armstrong@linaro.org> wrote: > >> Hi, >> >> On 29/11/2023 14:39, Jerome Brunet wrote: >>> Add a new compatible for the pwm found in the meson8 to sm1 Amlogic SoCs, >>> dealing with clocks differently. This does not enable new HW. It is meant >>> to fix a bad DT ABI for the currently supported HW. >>> The original clock bindings describe which input the PWM channel >>> multiplexer should pick among its possible parents, which are >>> hard-coded in the driver. As such, it is a setting tied to the driver >>> implementation and does not describe the HW. >>> The new bindings introduce here describe the clocks input of the PWM >>> block >>> as they exist. >>> The old compatible is deprecated but kept to maintain ABI compatibility. >>> The SoC specific compatibles introduced match the SoC families supported >>> by the original bindings. >>> Signed-off-by: Jerome Brunet <jbrunet@baylibre.com> >>> --- >>> .../devicetree/bindings/pwm/pwm-amlogic.yaml | 52 ++++++++++++++++--- >>> 1 file changed, 46 insertions(+), 6 deletions(-) >>> diff --git a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>> b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>> index 387976ed36d5..eece390114a3 100644 >>> --- a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>> +++ b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>> @@ -21,23 +21,35 @@ properties: >>> - amlogic,meson-g12a-ee-pwm >>> - amlogic,meson-g12a-ao-pwm-ab >>> - amlogic,meson-g12a-ao-pwm-cd >>> - - amlogic,meson-s4-pwm >>> + deprecated: true >>> - items: >>> - const: amlogic,meson-gx-pwm >>> - const: amlogic,meson-gxbb-pwm >>> + deprecated: true >>> - items: >>> - const: amlogic,meson-gx-ao-pwm >>> - const: amlogic,meson-gxbb-ao-pwm >>> + deprecated: true >>> - items: >>> - const: amlogic,meson8-pwm >>> - const: amlogic,meson8b-pwm >>> + deprecated: true >> >> I think deprecated should be moved in a third patch > > The complain on v2 was that it was not clear the new binding was making > the old one obsolete. It looked to me that the deprecation old bindings > needed to go together with the introduction of the new. > > I don't mind one way or the other > > Is there a rule somewhere about this ? Not sure about that, I don't think it's a problem to have both valid at the same time, setting them deprecated afterwards looks cleaner to avoid mixing too much changes at the same time. Neil > >> >>> + - const: amlogic,meson8-pwm-v2 >>> + - items: >>> + - enum: >>> + - amlogic,meson8b-pwm-v2 >>> + - amlogic,meson-gxbb-pwm-v2 >>> + - amlogic,meson-axg-pwm-v2 >>> + - amlogic,meson-g12-pwm-v2 >>> + - const: amlogic,meson8-pwm-v2 >>> + - const: amlogic,meson-s4-pwm >>> reg: >>> maxItems: 1 >>> clocks: >>> minItems: 1 >>> - maxItems: 2 >>> + maxItems: 4 >>> clock-names: >>> minItems: 1 >>> @@ -58,7 +70,6 @@ allOf: >>> compatible: >>> contains: >>> enum: >>> - - amlogic,meson8-pwm >>> - amlogic,meson8b-pwm >>> - amlogic,meson-gxbb-pwm >>> - amlogic,meson-gxbb-ao-pwm >>> @@ -67,14 +78,15 @@ allOf: >>> - amlogic,meson-g12a-ee-pwm >>> - amlogic,meson-g12a-ao-pwm-ab >>> - amlogic,meson-g12a-ao-pwm-cd >>> - - amlogic,meson-gx-pwm >>> - - amlogic,meson-gx-ao-pwm >> >> I don't understand why those entries are removed > > It's a mistake. It should not have been added to begin with in > the first patch. "amlogic,meson-gx-*" must go along with > "amlogic,meson-gxbb-*" so it matches correctly without it. > > I'll fix it > >> >>> then: >>> - # Historic bindings tied to the driver implementation >>> + # Obsolete historic bindings tied to the driver implementation >>> # The clocks provided here are meant to be matched with the input >>> # known (hard-coded) in the driver and used to select pwm clock >>> # source. Currently, the linux driver ignores this. >>> + # This is kept to maintain ABI backward compatibility. >> >> Same here, this should go in a third patch >> >>> properties: >>> + clocks: >>> + maxItems: 2 >>> clock-names: >>> oneOf: >>> - items: >>> @@ -83,6 +95,27 @@ allOf: >>> - const: clkin0 >>> - const: clkin1 >>> + # Newer binding where clock describe the actual clock inputs of the >>> pwm >>> + # block. These are necessary but some inputs may be grounded. >>> + - if: >>> + properties: >>> + compatible: >>> + contains: >>> + enum: >>> + - amlogic,meson8-pwm-v2 >>> + then: >>> + properties: >>> + clocks: >>> + minItems: 1 >>> + items: >>> + - description: input clock 0 of the pwm block >>> + - description: input clock 1 of the pwm block >>> + - description: input clock 2 of the pwm block >>> + - description: input clock 3 of the pwm block >>> + clock-names: false >>> + required: >>> + - clocks >>> + >>> # Newer IP block take a single input per channel, instead of 4 inputs >>> # for both channels >>> - if: >>> @@ -112,6 +145,13 @@ examples: >>> clock-names = "clkin0", "clkin1"; >>> #pwm-cells = <3>; >>> }; >>> + - | >>> + pwm@2000 { >>> + compatible = "amlogic,meson8-pwm-v2"; >>> + reg = <0x1000 0x10>; >>> + clocks = <&xtal>, <0>, <&fdiv4>, <&fdiv5>; >>> + #pwm-cells = <3>; >>> + }; >>> - | >>> pwm@1000 { >>> compatible = "amlogic,meson-s4-pwm"; >> >> Neil > >
On 29/11/2023 17:41, neil.armstrong@linaro.org wrote: >>>> .../devicetree/bindings/pwm/pwm-amlogic.yaml | 52 ++++++++++++++++--- >>>> 1 file changed, 46 insertions(+), 6 deletions(-) >>>> diff --git a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>>> b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>>> index 387976ed36d5..eece390114a3 100644 >>>> --- a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>>> +++ b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>>> @@ -21,23 +21,35 @@ properties: >>>> - amlogic,meson-g12a-ee-pwm >>>> - amlogic,meson-g12a-ao-pwm-ab >>>> - amlogic,meson-g12a-ao-pwm-cd >>>> - - amlogic,meson-s4-pwm >>>> + deprecated: true >>>> - items: >>>> - const: amlogic,meson-gx-pwm >>>> - const: amlogic,meson-gxbb-pwm >>>> + deprecated: true >>>> - items: >>>> - const: amlogic,meson-gx-ao-pwm >>>> - const: amlogic,meson-gxbb-ao-pwm >>>> + deprecated: true >>>> - items: >>>> - const: amlogic,meson8-pwm >>>> - const: amlogic,meson8b-pwm >>>> + deprecated: true >>> >>> I think deprecated should be moved in a third patch >> >> The complain on v2 was that it was not clear the new binding was making >> the old one obsolete. It looked to me that the deprecation old bindings >> needed to go together with the introduction of the new. >> >> I don't mind one way or the other >> >> Is there a rule somewhere about this ? > > Not sure about that, I don't think it's a problem to have both valid > at the same time, setting them deprecated afterwards looks cleaner > to avoid mixing too much changes at the same time. For me current order is correct and intuitive: you add new binding, because old binding was wrong, so the old binding should be deprecated. Otherwise you have a state with both new and old binding and one could question - why did we need new binding? For dtschema it does not matter, but it matters how we read the code. Best regards, Krzysztof
On 30/11/2023 09:36, Krzysztof Kozlowski wrote: > On 29/11/2023 17:41, neil.armstrong@linaro.org wrote: >>>>> .../devicetree/bindings/pwm/pwm-amlogic.yaml | 52 ++++++++++++++++--- >>>>> 1 file changed, 46 insertions(+), 6 deletions(-) >>>>> diff --git a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>>>> b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>>>> index 387976ed36d5..eece390114a3 100644 >>>>> --- a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>>>> +++ b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml >>>>> @@ -21,23 +21,35 @@ properties: >>>>> - amlogic,meson-g12a-ee-pwm >>>>> - amlogic,meson-g12a-ao-pwm-ab >>>>> - amlogic,meson-g12a-ao-pwm-cd >>>>> - - amlogic,meson-s4-pwm >>>>> + deprecated: true >>>>> - items: >>>>> - const: amlogic,meson-gx-pwm >>>>> - const: amlogic,meson-gxbb-pwm >>>>> + deprecated: true >>>>> - items: >>>>> - const: amlogic,meson-gx-ao-pwm >>>>> - const: amlogic,meson-gxbb-ao-pwm >>>>> + deprecated: true >>>>> - items: >>>>> - const: amlogic,meson8-pwm >>>>> - const: amlogic,meson8b-pwm >>>>> + deprecated: true >>>> >>>> I think deprecated should be moved in a third patch >>> >>> The complain on v2 was that it was not clear the new binding was making >>> the old one obsolete. It looked to me that the deprecation old bindings >>> needed to go together with the introduction of the new. >>> >>> I don't mind one way or the other >>> >>> Is there a rule somewhere about this ? >> >> Not sure about that, I don't think it's a problem to have both valid >> at the same time, setting them deprecated afterwards looks cleaner >> to avoid mixing too much changes at the same time. > > For me current order is correct and intuitive: you add new binding, > because old binding was wrong, so the old binding should be deprecated. > Otherwise you have a state with both new and old binding and one could > question - why did we need new binding? For dtschema it does not matter, > but it matters how we read the code. Ack thx for the clarification > > Best regards, > Krzysztof > Thanks, Neil
diff --git a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml index 387976ed36d5..eece390114a3 100644 --- a/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml +++ b/Documentation/devicetree/bindings/pwm/pwm-amlogic.yaml @@ -21,23 +21,35 @@ properties: - amlogic,meson-g12a-ee-pwm - amlogic,meson-g12a-ao-pwm-ab - amlogic,meson-g12a-ao-pwm-cd - - amlogic,meson-s4-pwm + deprecated: true - items: - const: amlogic,meson-gx-pwm - const: amlogic,meson-gxbb-pwm + deprecated: true - items: - const: amlogic,meson-gx-ao-pwm - const: amlogic,meson-gxbb-ao-pwm + deprecated: true - items: - const: amlogic,meson8-pwm - const: amlogic,meson8b-pwm + deprecated: true + - const: amlogic,meson8-pwm-v2 + - items: + - enum: + - amlogic,meson8b-pwm-v2 + - amlogic,meson-gxbb-pwm-v2 + - amlogic,meson-axg-pwm-v2 + - amlogic,meson-g12-pwm-v2 + - const: amlogic,meson8-pwm-v2 + - const: amlogic,meson-s4-pwm reg: maxItems: 1 clocks: minItems: 1 - maxItems: 2 + maxItems: 4 clock-names: minItems: 1 @@ -58,7 +70,6 @@ allOf: compatible: contains: enum: - - amlogic,meson8-pwm - amlogic,meson8b-pwm - amlogic,meson-gxbb-pwm - amlogic,meson-gxbb-ao-pwm @@ -67,14 +78,15 @@ allOf: - amlogic,meson-g12a-ee-pwm - amlogic,meson-g12a-ao-pwm-ab - amlogic,meson-g12a-ao-pwm-cd - - amlogic,meson-gx-pwm - - amlogic,meson-gx-ao-pwm then: - # Historic bindings tied to the driver implementation + # Obsolete historic bindings tied to the driver implementation # The clocks provided here are meant to be matched with the input # known (hard-coded) in the driver and used to select pwm clock # source. Currently, the linux driver ignores this. + # This is kept to maintain ABI backward compatibility. properties: + clocks: + maxItems: 2 clock-names: oneOf: - items: @@ -83,6 +95,27 @@ allOf: - const: clkin0 - const: clkin1 + # Newer binding where clock describe the actual clock inputs of the pwm + # block. These are necessary but some inputs may be grounded. + - if: + properties: + compatible: + contains: + enum: + - amlogic,meson8-pwm-v2 + then: + properties: + clocks: + minItems: 1 + items: + - description: input clock 0 of the pwm block + - description: input clock 1 of the pwm block + - description: input clock 2 of the pwm block + - description: input clock 3 of the pwm block + clock-names: false + required: + - clocks + # Newer IP block take a single input per channel, instead of 4 inputs # for both channels - if: @@ -112,6 +145,13 @@ examples: clock-names = "clkin0", "clkin1"; #pwm-cells = <3>; }; + - | + pwm@2000 { + compatible = "amlogic,meson8-pwm-v2"; + reg = <0x1000 0x10>; + clocks = <&xtal>, <0>, <&fdiv4>, <&fdiv5>; + #pwm-cells = <3>; + }; - | pwm@1000 { compatible = "amlogic,meson-s4-pwm";
Add a new compatible for the pwm found in the meson8 to sm1 Amlogic SoCs, dealing with clocks differently. This does not enable new HW. It is meant to fix a bad DT ABI for the currently supported HW. The original clock bindings describe which input the PWM channel multiplexer should pick among its possible parents, which are hard-coded in the driver. As such, it is a setting tied to the driver implementation and does not describe the HW. The new bindings introduce here describe the clocks input of the PWM block as they exist. The old compatible is deprecated but kept to maintain ABI compatibility. The SoC specific compatibles introduced match the SoC families supported by the original bindings. Signed-off-by: Jerome Brunet <jbrunet@baylibre.com> --- .../devicetree/bindings/pwm/pwm-amlogic.yaml | 52 ++++++++++++++++--- 1 file changed, 46 insertions(+), 6 deletions(-)