Message ID | 2778d0d4813cc56be851719846afecbab5f2e657.1542362530.git.viresh.kumar@linaro.org (mailing list archive) |
---|---|
State | Accepted |
Commit | a5c12132d2167c7526a44e61cb368212afc7da16 |
Headers | show |
Series | ARM64: dts: Fix incomplete cooling-maps | expand |
On 16/11/2018 11:04, Viresh Kumar wrote: > Each CPU can (and does) participate in cooling down the system but the > DT only captures a handful of them, normally CPU0, in the cooling maps. > Things work by chance currently as under normal circumstances its the > first CPU of each cluster which is used by the operating systems to > probe the cooling devices. But as soon as this CPU ordering changes and > any other CPU is used to bring up the cooling device, we will start > seeing failures. > > Also the DT is rather incomplete when we list only one CPU in the > cooling maps, as the hardware doesn't have any such limitations. > > Update cooling maps to include all devices affected by individual trip > points. > > Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> > --- > .../dts/amlogic/meson-gxm-khadas-vim2.dts | 22 ++++++++----------- > 1 file changed, 9 insertions(+), 13 deletions(-) > > diff --git a/arch/arm64/boot/dts/amlogic/meson-gxm-khadas-vim2.dts b/arch/arm64/boot/dts/amlogic/meson-gxm-khadas-vim2.dts > index 313f88f8759e..cfc92d06a28f 100644 > --- a/arch/arm64/boot/dts/amlogic/meson-gxm-khadas-vim2.dts > +++ b/arch/arm64/boot/dts/amlogic/meson-gxm-khadas-vim2.dts > @@ -132,19 +132,15 @@ > > map1 { > trip = <&cpu_alert1>; > - cooling-device = <&gpio_fan 2 THERMAL_NO_LIMIT>; > - }; > - > - map2 { > - trip = <&cpu_alert1>; > - cooling-device = > - <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; > - }; > - > - map3 { > - trip = <&cpu_alert1>; > - cooling-device = > - <&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; > + cooling-device = <&gpio_fan 2 THERMAL_NO_LIMIT>, > + <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, > + <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, > + <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, > + <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, > + <&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, > + <&cpu5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, > + <&cpu6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, > + <&cpu7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; > }; > }; > }; > Acked-by: Neil Armstrong <narmstrong@baylibre.com>
Viresh Kumar <viresh.kumar@linaro.org> writes: > Each CPU can (and does) participate in cooling down the system but the > DT only captures a handful of them, normally CPU0, in the cooling maps. > Things work by chance currently as under normal circumstances its the > first CPU of each cluster which is used by the operating systems to > probe the cooling devices. But as soon as this CPU ordering changes and > any other CPU is used to bring up the cooling device, we will start > seeing failures. > > Also the DT is rather incomplete when we list only one CPU in the > cooling maps, as the hardware doesn't have any such limitations. > > Update cooling maps to include all devices affected by individual trip > points. > > Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Queued for v4.21, Thanks! Kevin
diff --git a/arch/arm64/boot/dts/amlogic/meson-gxm-khadas-vim2.dts b/arch/arm64/boot/dts/amlogic/meson-gxm-khadas-vim2.dts index 313f88f8759e..cfc92d06a28f 100644 --- a/arch/arm64/boot/dts/amlogic/meson-gxm-khadas-vim2.dts +++ b/arch/arm64/boot/dts/amlogic/meson-gxm-khadas-vim2.dts @@ -132,19 +132,15 @@ map1 { trip = <&cpu_alert1>; - cooling-device = <&gpio_fan 2 THERMAL_NO_LIMIT>; - }; - - map2 { - trip = <&cpu_alert1>; - cooling-device = - <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; - }; - - map3 { - trip = <&cpu_alert1>; - cooling-device = - <&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; + cooling-device = <&gpio_fan 2 THERMAL_NO_LIMIT>, + <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; }; }; };
Each CPU can (and does) participate in cooling down the system but the DT only captures a handful of them, normally CPU0, in the cooling maps. Things work by chance currently as under normal circumstances its the first CPU of each cluster which is used by the operating systems to probe the cooling devices. But as soon as this CPU ordering changes and any other CPU is used to bring up the cooling device, we will start seeing failures. Also the DT is rather incomplete when we list only one CPU in the cooling maps, as the hardware doesn't have any such limitations. Update cooling maps to include all devices affected by individual trip points. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> --- .../dts/amlogic/meson-gxm-khadas-vim2.dts | 22 ++++++++----------- 1 file changed, 9 insertions(+), 13 deletions(-)