@@ -235,7 +235,7 @@
};
&mmc1 {
- vmmc-supply = <&vmmcsd_fixed>;
+ vmmc-supply = <&ldo9_reg>;
bus-width = <4>;
};
@@ -348,10 +348,8 @@
ldo1_reg: ldo1 {
/* VDDAPHY_CAM: vdda_csiport */
regulator-name = "ldo1";
- regulator-min-microvolt = <2800000>;
- regulator-max-microvolt = <2800000>;
- regulator-always-on;
- regulator-boot-on;
+ regulator-min-microvolt = <1500000>;
+ regulator-max-microvolt = <1800000>;
};
ldo2_reg: ldo2 {
@@ -366,19 +364,18 @@
ldo3_reg: ldo3 {
/* VDDAPHY_MDM: vdda_lli */
regulator-name = "ldo3";
- regulator-min-microvolt = <3000000>;
- regulator-max-microvolt = <3000000>;
- regulator-always-on;
+ regulator-min-microvolt = <1500000>;
+ regulator-max-microvolt = <1500000>;
regulator-boot-on;
+ /* Only if Modem is used */
+ status = "disabled";
};
ldo4_reg: ldo4 {
/* VDDAPHY_DISP: vdda_dsiport/hdmi */
regulator-name = "ldo4";
- regulator-min-microvolt = <2200000>;
- regulator-max-microvolt = <2200000>;
- regulator-always-on;
- regulator-boot-on;
+ regulator-min-microvolt = <1500000>;
+ regulator-max-microvolt = <1800000>;
};
ldo5_reg: ldo5 {
@@ -393,8 +390,8 @@
ldo6_reg: ldo6 {
/* VDDS_1V2_WKUP: hsic/ldo_emu_wkup */
regulator-name = "ldo6";
- regulator-min-microvolt = <1500000>;
- regulator-max-microvolt = <1500000>;
+ regulator-min-microvolt = <1200000>;
+ regulator-max-microvolt = <1200000>;
regulator-always-on;
regulator-boot-on;
};
@@ -402,10 +399,10 @@
ldo7_reg: ldo7 {
/* VDD_VPP: vpp1 */
regulator-name = "ldo7";
- regulator-min-microvolt = <1500000>;
- regulator-max-microvolt = <1500000>;
- regulator-always-on;
- regulator-boot-on;
+ regulator-min-microvolt = <2000000>;
+ regulator-max-microvolt = <2000000>;
+ /* Only for efuse reprograming! */
+ status = "disabled";
};
ldo8_reg: ldo8 {
@@ -421,8 +418,7 @@
/* VCC_DV_SDIO: vdds_sdcard */
regulator-name = "ldo9";
regulator-min-microvolt = <1800000>;
- regulator-max-microvolt = <3300000>;
- regulator-always-on;
+ regulator-max-microvolt = <3000000>;
regulator-boot-on;
};
@@ -443,6 +439,13 @@
regulator-always-on;
regulator-boot-on;
};
+
+ regen3_reg: regen3 {
+ /* REGEN3 controls LDO9 supply to card */
+ regulator-name = "regen3";
+ regulator-always-on;
+ regulator-boot-on;
+ };
};
};
};