@@ -2,8 +2,10 @@ Marvell Armada 370 and Armada XP Timers
---------------------------------------
Required properties:
-- compatible: Should be either "marvell,armada-370-timer" or
- "marvell,armada-xp-timer" as appropriate.
+- compatible: Should be one of the following
+ "marvell,armada-370-timer",
+ "marvell,armada-375-timer",
+ "marvell,armada-xp-timer".
- interrupts: Should contain the list of Global Timer interrupts and
then local timer interrupts
- reg: Should contain location and length for timers register. First
@@ -13,7 +15,8 @@ Required properties:
Clocks required for compatible = "marvell,armada-370-timer":
- clocks : Must contain a single entry describing the clock input
-Clocks required for compatible = "marvell,armada-xp-timer":
+Clocks required for compatibles = "marvell,armada-xp-timer",
+ "marvell,armada-375-timer":
- clocks : Must contain an entry for each entry in clock-names.
- clock-names : Must include the following entries:
"nbclk" (L2/coherency fabric clock),
@@ -301,6 +301,34 @@ static void __init armada_xp_timer_init(struct device_node *np)
CLOCKSOURCE_OF_DECLARE(armada_xp, "marvell,armada-xp-timer",
armada_xp_timer_init);
+static void __init armada_375_timer_init(struct device_node *np)
+{
+ struct clk *clk;
+
+ clk = of_clk_get_by_name(np, "fixed");
+ if (!IS_ERR(clk)) {
+ clk_prepare_enable(clk);
+ timer_clk = clk_get_rate(clk);
+ } else {
+
+ /*
+ * This fallback is required in order to retain proper
+ * devicetree backwards compatibility.
+ */
+ clk = of_clk_get(np, 0);
+
+ /* Must have at least a clock */
+ BUG_ON(IS_ERR(clk));
+ clk_prepare_enable(clk);
+ timer_clk = clk_get_rate(clk) / TIMER_DIVIDER;
+ timer25Mhz = false;
+ }
+
+ armada_370_xp_timer_common_init(np);
+}
+CLOCKSOURCE_OF_DECLARE(armada_375, "marvell,armada-375-timer",
+ armada_375_timer_init);
+
static void __init armada_370_timer_init(struct device_node *np)
{
struct clk *clk = of_clk_get(np, 0);