Addy, On Thu, Feb 19, 2015 at 6:55 PM, Addy Ke <addy.ke@rock-chips.com> wrote: > The STOP command can terminate a data transfer between a memory card and > mmc controller. > > As show in Synopsys DesignWare Cores Mobile Stroage Host Databook: > Data timeout and Data end-bit error will terminate further data transfer > by mmc controller. So we should not send abort command to terminate a > data transfer again if we got DRTO and EBE interrupt. > > After this patch, all mmc_test cases can pass on RK3288-Pink2 board. > > Signed-off-by: Addy Ke <addy.ke@rock-chips.com> > --- > Changes in v2: > - DRTO and EBE are both set, should not send abort command too, > suggested by Doug Anderson. > > drivers/mmc/host/dw_mmc.c | 10 ++++++++-- > 1 file changed, 8 insertions(+), 2 deletions(-) I also suggested that you change the subject to "mmc: dw_mmc: fix mmc_test by not sending abort for DRTO / EBE errors" which you didn't do. ...I guess that's not critical. Perhaps Jaehoon (who is collecting patches for Ulf now I think) can adjust the subject when he applies. In any case, v2 fixes my problems and seems OK to me. Reviewed-by: Doug Anderson <dianders@chromium.org> On rk3288 on a 3.14 kernel w/ lotsa backports: Tested-by: Doug Anderson <dianders@chromium.org>
Hello Addy, On 02/20/2015 03:55 AM, Addy Ke wrote: > The STOP command can terminate a data transfer between a memory card and > mmc controller. > > As show in Synopsys DesignWare Cores Mobile Stroage Host Databook: s/Stroage/Storage but maybe Ulf can amend the typo when applying? > Data timeout and Data end-bit error will terminate further data transfer > by mmc controller. So we should not send abort command to terminate a > data transfer again if we got DRTO and EBE interrupt. > > After this patch, all mmc_test cases can pass on RK3288-Pink2 board. > > Signed-off-by: Addy Ke <addy.ke@rock-chips.com> I did not run all the tests listed in /sys/kernel/debug/mmc*/*/testlist because some of them will overwrite the data in my card but at least the read ones completed successfully and $subject does not cause a regression in the Exynos5250 Snow, Exynos5420 Peach Pit and Exynos5800 Peach Pi Chromebooks where I tested it. Tested-by: Javier Martinez Canillas <javier.martinez@collabora.co.uk> Best regards, Javier
Hi, I will apply into my-tree after change the subject and fix typo. Acked-by: Jaehoon Chung <jh80.chung@samsung.com> Best Regards, Jaehoon Chung On 02/26/2015 03:17 AM, Javier Martinez Canillas wrote: > Hello Addy, > > On 02/20/2015 03:55 AM, Addy Ke wrote: >> The STOP command can terminate a data transfer between a memory card and >> mmc controller. >> >> As show in Synopsys DesignWare Cores Mobile Stroage Host Databook: > > s/Stroage/Storage but maybe Ulf can amend the typo when applying? > >> Data timeout and Data end-bit error will terminate further data transfer >> by mmc controller. So we should not send abort command to terminate a >> data transfer again if we got DRTO and EBE interrupt. >> >> After this patch, all mmc_test cases can pass on RK3288-Pink2 board. >> >> Signed-off-by: Addy Ke <addy.ke@rock-chips.com> > > I did not run all the tests listed in /sys/kernel/debug/mmc*/*/testlist > because some of them will overwrite the data in my card but at least > the read ones completed successfully and $subject does not cause a > regression in the Exynos5250 Snow, Exynos5420 Peach Pit and Exynos5800 > Peach Pi Chromebooks where I tested it. > > Tested-by: Javier Martinez Canillas <javier.martinez@collabora.co.uk> > > Best regards, > Javier >
diff --git a/drivers/mmc/host/dw_mmc.c b/drivers/mmc/host/dw_mmc.c index 4d2e3c2..a27048a 100644 --- a/drivers/mmc/host/dw_mmc.c +++ b/drivers/mmc/host/dw_mmc.c @@ -1520,7 +1520,10 @@ static void dw_mci_tasklet_func(unsigned long priv) if (test_and_clear_bit(EVENT_DATA_ERROR, &host->pending_events)) { dw_mci_stop_dma(host); - send_stop_abort(host, data); + if (data->stop || + !(host->data_status & (SDMMC_INT_DRTO | + SDMMC_INT_EBE))) + send_stop_abort(host, data); state = STATE_DATA_ERROR; break; } @@ -1547,7 +1550,10 @@ static void dw_mci_tasklet_func(unsigned long priv) if (test_and_clear_bit(EVENT_DATA_ERROR, &host->pending_events)) { dw_mci_stop_dma(host); - send_stop_abort(host, data); + if (data->stop || + !(host->data_status & (SDMMC_INT_DRTO | + SDMMC_INT_EBE))) + send_stop_abort(host, data); state = STATE_DATA_ERROR; break; }
The STOP command can terminate a data transfer between a memory card and mmc controller. As show in Synopsys DesignWare Cores Mobile Stroage Host Databook: Data timeout and Data end-bit error will terminate further data transfer by mmc controller. So we should not send abort command to terminate a data transfer again if we got DRTO and EBE interrupt. After this patch, all mmc_test cases can pass on RK3288-Pink2 board. Signed-off-by: Addy Ke <addy.ke@rock-chips.com> --- Changes in v2: - DRTO and EBE are both set, should not send abort command too, suggested by Doug Anderson. drivers/mmc/host/dw_mmc.c | 10 ++++++++-- 1 file changed, 8 insertions(+), 2 deletions(-)