new file mode 100644
@@ -0,0 +1,44 @@
+Tegra124 CPU frequency scaling driver bindings
+----------------------------------------------
+
+Both required and optional properties listed below must be defined
+under node /cpus/cpu@0.
+
+Required properties:
+- clocks: Must contain an entry for each entry in clock-names.
+ See ../clocks/clock-bindings.txt for details.
+- clock-names: Must include the following entries:
+ - cpu_g: Clock mux for the fast CPU cluster.
+ - cpu_lp: Clock mux for the low-power CPU cluster.
+ - pll_x: Fast PLL clocksource.
+ - pll_p: Auxiliary PLL used during fast PLL rate changes.
+ - dfll: Fast DFLL clocksource that also automatically scales CPU voltage.
+- vdd-cpu-supply: Regulator for CPU voltage
+
+Optional properties:
+- clock-latency: Specify the possible maximum transition latency for clock,
+ in unit of nanoseconds.
+
+Example:
+--------
+cpus {
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ cpu@0 {
+ device_type = "cpu";
+ compatible = "arm,cortex-a15";
+ reg = <0>;
+
+ clocks = <&tegra_car TEGRA124_CLK_CCLK_G>,
+ <&tegra_car TEGRA124_CLK_CCLK_LP>,
+ <&tegra_car TEGRA124_CLK_PLL_X>,
+ <&tegra_car TEGRA124_CLK_PLL_P>,
+ <&dfll>;
+ clock-names = "cpu_g", "cpu_lp", "pll_x", "pll_p", "dfll";
+ clock-latency = <300000>;
+ vdd-cpu-supply: <&vdd_cpu>;
+ };
+
+ <...>
+};