new file mode 100644
@@ -0,0 +1,7 @@
+Innolux AT070TN92 7.0" WQVGA TFT LCD panel
+
+Required properties:
+- compatible: should be "innolux,at070tn92"
+
+This binding is compatible with the simple-panel binding, which is specified
+in simple-panel.txt in this directory.
@@ -822,6 +822,29 @@ static const struct panel_desc innolux_at043tn24 = {
.bus_format = MEDIA_BUS_FMT_RGB888_1X24,
};
+static const struct drm_display_mode innolux_at070tn92_mode = {
+ .clock = 33333,
+ .hdisplay = 800,
+ .hsync_start = 800 + 210,
+ .hsync_end = 800 + 210 + 20,
+ .htotal = 800 + 210 + 20 + 46,
+ .vdisplay = 480,
+ .vsync_start = 480 + 22,
+ .vsync_end = 480 + 22 + 10,
+ .vtotal = 480 + 22 + 23 + 10,
+ .vrefresh = 60,
+};
+
+static const struct panel_desc innolux_at070tn92 = {
+ .modes = &innolux_at070tn92_mode,
+ .num_modes = 1,
+ .size = {
+ .width = 154,
+ .height = 86,
+ },
+ .bus_format = MEDIA_BUS_FMT_RGB888_1X24,
+};
+
static const struct drm_display_mode innolux_g121i1_l01_mode = {
.clock = 71000,
.hdisplay = 1280,
@@ -1362,6 +1385,9 @@ static const struct of_device_id platform_of_match[] = {
.compatible = "innolux,at043tn24",
.data = &innolux_at043tn24,
}, {
+ .compatible = "innolux,at070tn92",
+ .data = &innolux_at070tn92,
+ }, {
.compatible ="innolux,g121i1-l01",
.data = &innolux_g121i1_l01
}, {