Message ID | 1484311084-31547-4-git-send-email-bgolaszewski@baylibre.com (mailing list archive) |
---|---|
State | New, archived |
Headers | show |
On 01/13/2017 06:37 AM, Bartosz Golaszewski wrote: > Add DT bindings for the TI DA850 AHCI SATA controller. > > Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com> > --- > .../devicetree/bindings/ata/ahci-da850.txt | 21 +++++++++++++++++++++ > 1 file changed, 21 insertions(+) > create mode 100644 Documentation/devicetree/bindings/ata/ahci-da850.txt > > diff --git a/Documentation/devicetree/bindings/ata/ahci-da850.txt b/Documentation/devicetree/bindings/ata/ahci-da850.txt > new file mode 100644 > index 0000000..d07c241 > --- /dev/null > +++ b/Documentation/devicetree/bindings/ata/ahci-da850.txt > @@ -0,0 +1,21 @@ > +Device tree binding for the TI DA850 AHCI SATA Controller > +--------------------------------------------------------- > + > +Required properties: > + - compatible: must be "ti,da850-ahci" > + - reg: physical base addresses and sizes of the controller's register areas > + - interrupts: interrupt specifier (refer to the interrupt binding) > + > +Optional properties: > + - clocks: clock specifier (refer to the common clock binding) > + - da850,clk_multiplier: the multiplier for the reference clock needed > + for 1.5GHz PLL output A clock multiplier property seems redundant if you are specifying a clock. It should be possible to get the rate from the clock to determine which multiplier is needed. > + > +Example: > + > + sata: ahci@0x218000 { > + compatible = "ti,da850-ahci"; > + reg = <0x218000 0x2000>, <0x22c018 0x4>; > + interrupts = <67>; > + da850,clk_multiplier = <7>; > + }; >
2017-01-13 20:25 GMT+01:00 David Lechner <david@lechnology.com>: > On 01/13/2017 06:37 AM, Bartosz Golaszewski wrote: >> >> Add DT bindings for the TI DA850 AHCI SATA controller. >> >> Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com> >> --- >> .../devicetree/bindings/ata/ahci-da850.txt | 21 >> +++++++++++++++++++++ >> 1 file changed, 21 insertions(+) >> create mode 100644 Documentation/devicetree/bindings/ata/ahci-da850.txt >> >> diff --git a/Documentation/devicetree/bindings/ata/ahci-da850.txt >> b/Documentation/devicetree/bindings/ata/ahci-da850.txt >> new file mode 100644 >> index 0000000..d07c241 >> --- /dev/null >> +++ b/Documentation/devicetree/bindings/ata/ahci-da850.txt >> @@ -0,0 +1,21 @@ >> +Device tree binding for the TI DA850 AHCI SATA Controller >> +--------------------------------------------------------- >> + >> +Required properties: >> + - compatible: must be "ti,da850-ahci" >> + - reg: physical base addresses and sizes of the controller's register >> areas >> + - interrupts: interrupt specifier (refer to the interrupt binding) >> + >> +Optional properties: >> + - clocks: clock specifier (refer to the common clock binding) >> + - da850,clk_multiplier: the multiplier for the reference clock needed >> + for 1.5GHz PLL output > > > A clock multiplier property seems redundant if you are specifying a clock. > It should be possible to get the rate from the clock to determine which > multiplier is needed. > I probably should have named it differently. This is not a multiplier of a clock derived from PLL0 or PLL1. Instead it's a value set by writing to the Port PHY Control Register (MPY bits) of the SATA controller that configures the multiplier for the external low-jitter clock. On the lcdk the signals (REFCLKP, REFCLKN) are provided by CDCM61001 (SATA OSCILLATOR component on the schematics). I'll find a better name and comment the property accordingly. FYI: the da850 platform does not use the common clock framework, so I don't specify the clock property on the sata node in the device tree. Instead I add the clock lookup entry in patch [01/10]. This is transparent for AHCI which can get the clock as usual by calling clk_get() in ahci_platform_get_resources(). Thanks, Bartosz Golaszewski
On Monday 16 January 2017 03:43 PM, Bartosz Golaszewski wrote: > 2017-01-13 20:25 GMT+01:00 David Lechner <david@lechnology.com>: >> On 01/13/2017 06:37 AM, Bartosz Golaszewski wrote: >>> >>> Add DT bindings for the TI DA850 AHCI SATA controller. >>> >>> Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com> >>> --- >>> .../devicetree/bindings/ata/ahci-da850.txt | 21 >>> +++++++++++++++++++++ >>> 1 file changed, 21 insertions(+) >>> create mode 100644 Documentation/devicetree/bindings/ata/ahci-da850.txt >>> >>> diff --git a/Documentation/devicetree/bindings/ata/ahci-da850.txt >>> b/Documentation/devicetree/bindings/ata/ahci-da850.txt >>> new file mode 100644 >>> index 0000000..d07c241 >>> --- /dev/null >>> +++ b/Documentation/devicetree/bindings/ata/ahci-da850.txt >>> @@ -0,0 +1,21 @@ >>> +Device tree binding for the TI DA850 AHCI SATA Controller >>> +--------------------------------------------------------- >>> + >>> +Required properties: >>> + - compatible: must be "ti,da850-ahci" >>> + - reg: physical base addresses and sizes of the controller's register >>> areas >>> + - interrupts: interrupt specifier (refer to the interrupt binding) >>> + >>> +Optional properties: >>> + - clocks: clock specifier (refer to the common clock binding) >>> + - da850,clk_multiplier: the multiplier for the reference clock needed >>> + for 1.5GHz PLL output >> >> >> A clock multiplier property seems redundant if you are specifying a clock. >> It should be possible to get the rate from the clock to determine which >> multiplier is needed. >> > > I probably should have named it differently. This is not a multiplier > of a clock derived from PLL0 or PLL1. Instead it's a value set by > writing to the Port PHY Control Register (MPY bits) of the SATA > controller that configures the multiplier for the external low-jitter > clock. On the lcdk the signals (REFCLKP, REFCLKN) are provided by > CDCM61001 (SATA OSCILLATOR component on the schematics). > > I'll find a better name and comment the property accordingly. > > FYI: the da850 platform does not use the common clock framework, so I > don't specify the clock property on the sata node in the device tree. > Instead I add the clock lookup entry in patch [01/10]. This is > transparent for AHCI which can get the clock as usual by calling > clk_get() in ahci_platform_get_resources(). I think David's point is that the SATA_REFCLK needs to be modeled as a actual clock input to the IP. You should be able to get the rate using clk_get_rate() and make the MPY bits calculation depending on the incoming rate. You should be able to model the clock even when not using common clock framework. DA850 AHCI does not use a con_id at the moment (it assumes a single clock), and that needs to change. Thanks, Sekhar
2017-01-16 13:45 GMT+01:00 Sekhar Nori <nsekhar@ti.com>: > On Monday 16 January 2017 03:43 PM, Bartosz Golaszewski wrote: >> 2017-01-13 20:25 GMT+01:00 David Lechner <david@lechnology.com>: >>> >>> A clock multiplier property seems redundant if you are specifying a clock. >>> It should be possible to get the rate from the clock to determine which >>> multiplier is needed. >>> >> >> I probably should have named it differently. This is not a multiplier >> of a clock derived from PLL0 or PLL1. Instead it's a value set by >> writing to the Port PHY Control Register (MPY bits) of the SATA >> controller that configures the multiplier for the external low-jitter >> clock. On the lcdk the signals (REFCLKP, REFCLKN) are provided by >> CDCM61001 (SATA OSCILLATOR component on the schematics). >> >> I'll find a better name and comment the property accordingly. >> >> FYI: the da850 platform does not use the common clock framework, so I >> don't specify the clock property on the sata node in the device tree. >> Instead I add the clock lookup entry in patch [01/10]. This is >> transparent for AHCI which can get the clock as usual by calling >> clk_get() in ahci_platform_get_resources(). > > I think David's point is that the SATA_REFCLK needs to be modeled as a > actual clock input to the IP. You should be able to get the rate using > clk_get_rate() and make the MPY bits calculation depending on the > incoming rate. > > You should be able to model the clock even when not using common clock > framework. > > DA850 AHCI does not use a con_id at the moment (it assumes a single > clock), and that needs to change. > It's true that once davinci gets ported (is this planned?) to using the common clock framework, we could just create a fixed-clock node in da850-lcdk for the SATA oscillator, so the new property is redundant. What I don't get is how should I model a clock that is not configurable and is board-specific? Is hard-coding the relevant rate in da850.c with a huge FIXME the right way? Thanks, Bartosz Golaszewski
diff --git a/Documentation/devicetree/bindings/ata/ahci-da850.txt b/Documentation/devicetree/bindings/ata/ahci-da850.txt new file mode 100644 index 0000000..d07c241 --- /dev/null +++ b/Documentation/devicetree/bindings/ata/ahci-da850.txt @@ -0,0 +1,21 @@ +Device tree binding for the TI DA850 AHCI SATA Controller +--------------------------------------------------------- + +Required properties: + - compatible: must be "ti,da850-ahci" + - reg: physical base addresses and sizes of the controller's register areas + - interrupts: interrupt specifier (refer to the interrupt binding) + +Optional properties: + - clocks: clock specifier (refer to the common clock binding) + - da850,clk_multiplier: the multiplier for the reference clock needed + for 1.5GHz PLL output + +Example: + + sata: ahci@0x218000 { + compatible = "ti,da850-ahci"; + reg = <0x218000 0x2000>, <0x22c018 0x4>; + interrupts = <67>; + da850,clk_multiplier = <7>; + };
Add DT bindings for the TI DA850 AHCI SATA controller. Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com> --- .../devicetree/bindings/ata/ahci-da850.txt | 21 +++++++++++++++++++++ 1 file changed, 21 insertions(+) create mode 100644 Documentation/devicetree/bindings/ata/ahci-da850.txt