diff mbox

[1/3] dt-bindings: mfd: d1w: iproc: Documentation for d1w driver

Message ID 1502905525-5646-2-git-send-email-scott.branden@broadcom.com (mailing list archive)
State New, archived
Headers show

Commit Message

Scott Branden Aug. 16, 2017, 5:45 p.m. UTC
From: Shreesha Rajashekar <shreesha@broadcom.com>

Adding document for IPROC d1w driver.

Signed-off-by: Shreesha Rajashekar <shreesha@broadcom.com>
Signed-off-by: Scott Branden <scott.branden@broadcom.com>
---
 .../devicetree/bindings/mfd/brcm,iproc-d1w.txt     | 27 ++++++++++++++++++++++
 1 file changed, 27 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt

Comments

Rob Herring Aug. 16, 2017, 8:45 p.m. UTC | #1
On Wed, Aug 16, 2017 at 12:45 PM, Scott Branden
<scott.branden@broadcom.com> wrote:
> From: Shreesha Rajashekar <shreesha@broadcom.com>
>
> Adding document for IPROC d1w driver.
>
> Signed-off-by: Shreesha Rajashekar <shreesha@broadcom.com>
> Signed-off-by: Scott Branden <scott.branden@broadcom.com>
> ---
>  .../devicetree/bindings/mfd/brcm,iproc-d1w.txt     | 27 ++++++++++++++++++++++
>  1 file changed, 27 insertions(+)
>  create mode 100644 Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt

How is this an MFD? Should be bindings/w1/...

>
> diff --git a/Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt b/Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt
> new file mode 100644
> index 0000000..2bb99c1
> --- /dev/null
> +++ b/Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt
> @@ -0,0 +1,27 @@
> +* Broadcom Dallas One wire (D1W) bus master controller
> +
> +Required properties:
> +- compatible : should be "brcm,iproc-d1w"
> +- reg : Address and length of the register set for the device
> +- interrupts : IRQ number of D1W controller
> +
> +Optional properties:
> +- clocks : phandle of clock that supplies the module (required if platform
> +               clock bindings use device tree)
> +- clock-names : name for the clock
> +- clock-frequency : D1W divisor clock rate

This should be bus-frequency. We messed up on I2C.

> +- reset-recover-delay : Delay while reset D1W in milliseconds.

Is this a standard 1-wire bus operation? I'm guessing so, but if not
needs a vendor prefix.

Also, needs unit suffix as defined in property-units.txt.

> +
> +Example:
> +
> +- From bcm-cygnus.dtsi:
> +iproc_d1w: d1w@180ab000 {

Should be a generic name. So far in bindings/w1/ we have 3 different
ones in 3 bindings. Lets go with "onewire".

> +       compatible = "brcm,iproc_d1w";

Doesn't match the doc.

> +       reg = <0x180ab000 0x0f>;
> +       interrupts = <GIC_SPI 150 IRQ_TYPE_LEVEL_HIGH>;
> +       clocks = <&axi81_clk>;
> +       clock-names = "iproc_d1w_clk";
> +       clock-frequency = <100000000>;
> +       reset-recover-delay = <1>;
> +};
> +
> --
> 2.5.0
>
Scott Branden Aug. 17, 2017, 6:20 p.m. UTC | #2
Thanks for review Rob


On 17-08-16 01:45 PM, Rob Herring wrote:
> On Wed, Aug 16, 2017 at 12:45 PM, Scott Branden
> <scott.branden@broadcom.com> wrote:
>> From: Shreesha Rajashekar <shreesha@broadcom.com>
>>
>> Adding document for IPROC d1w driver.
>>
>> Signed-off-by: Shreesha Rajashekar <shreesha@broadcom.com>
>> Signed-off-by: Scott Branden <scott.branden@broadcom.com>
>> ---
>>   .../devicetree/bindings/mfd/brcm,iproc-d1w.txt     | 27 ++++++++++++++++++++++
>>   1 file changed, 27 insertions(+)
>>   create mode 100644 Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt
> How is this an MFD? Should be bindings/w1/...
>
>> diff --git a/Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt b/Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt
>> new file mode 100644
>> index 0000000..2bb99c1
>> --- /dev/null
>> +++ b/Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt
>> @@ -0,0 +1,27 @@
>> +* Broadcom Dallas One wire (D1W) bus master controller
>> +
>> +Required properties:
>> +- compatible : should be "brcm,iproc-d1w"
>> +- reg : Address and length of the register set for the device
>> +- interrupts : IRQ number of D1W controller
>> +
>> +Optional properties:
>> +- clocks : phandle of clock that supplies the module (required if platform
>> +               clock bindings use device tree)
>> +- clock-names : name for the clock
>> +- clock-frequency : D1W divisor clock rate
> This should be bus-frequency. We messed up on I2C.
>
>> +- reset-recover-delay : Delay while reset D1W in milliseconds.
> Is this a standard 1-wire bus operation? I'm guessing so, but if not
> needs a vendor prefix.
>
> Also, needs unit suffix as defined in property-units.txt.
>
>> +
>> +Example:
>> +
>> +- From bcm-cygnus.dtsi:
>> +iproc_d1w: d1w@180ab000 {
> Should be a generic name. So far in bindings/w1/ we have 3 different
> ones in 3 bindings. Lets go with "onewire".
>
>> +       compatible = "brcm,iproc_d1w";
> Doesn't match the doc.
We have some cleanup work to do.  Need to move to mfd and address your 
comments.
>
>> +       reg = <0x180ab000 0x0f>;
>> +       interrupts = <GIC_SPI 150 IRQ_TYPE_LEVEL_HIGH>;
>> +       clocks = <&axi81_clk>;
>> +       clock-names = "iproc_d1w_clk";
>> +       clock-frequency = <100000000>;
>> +       reset-recover-delay = <1>;
>> +};
>> +
>> --
>> 2.5.0
>>
diff mbox

Patch

diff --git a/Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt b/Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt
new file mode 100644
index 0000000..2bb99c1
--- /dev/null
+++ b/Documentation/devicetree/bindings/mfd/brcm,iproc-d1w.txt
@@ -0,0 +1,27 @@ 
+* Broadcom Dallas One wire (D1W) bus master controller
+
+Required properties:
+- compatible : should be "brcm,iproc-d1w"
+- reg : Address and length of the register set for the device
+- interrupts : IRQ number of D1W controller
+
+Optional properties:
+- clocks : phandle of clock that supplies the module (required if platform
+		clock bindings use device tree)
+- clock-names : name for the clock
+- clock-frequency : D1W divisor clock rate
+- reset-recover-delay : Delay while reset D1W in milliseconds.
+
+Example:
+
+- From bcm-cygnus.dtsi:
+iproc_d1w: d1w@180ab000 {
+	compatible = "brcm,iproc_d1w";
+	reg = <0x180ab000 0x0f>;
+	interrupts = <GIC_SPI 150 IRQ_TYPE_LEVEL_HIGH>;
+	clocks = <&axi81_clk>;
+	clock-names = "iproc_d1w_clk";
+	clock-frequency = <100000000>;
+	reset-recover-delay = <1>;
+};
+