@@ -29,6 +29,7 @@ Mandatory properties specific to STM32 DSI:
- compatible: "st,stm32-dsi".
- clock-names:
- phy pll reference clock string name, must be "ref".
+ - DPI/RGB input pixel clock string name, must be "px_clk".
- resets: see [5].
- reset-names: see [5].
@@ -97,8 +98,9 @@ Example 2: DSI panel
#size-cells = <0>;
compatible = "st,stm32-dsi";
reg = <0x40016c00 0x800>;
- clocks = <&rcc 1 CLK_F469_DSI>, <&clk_hse>;
- clock-names = "pclk", "ref";
+ clocks = <&rcc 1 CLK_F469_DSI>, <&clk_hse>,
+ <&rcc 1 CLK_LCD>;
+ clock-names = "pclk", "ref", "px_clk";
resets = <&rcc STM32F4_APB2_RESET(DSI)>;
reset-names = "apb";
Add the DPI/RGB input pixel clock in mandatory properties because it really offers a better preciseness for timing computations. Signed-off-by: Philippe Cornu <philippe.cornu@st.com> --- Please apply "dt-bindings: display: stm32: correct clock-names in dsi panel example" before this patch. Changes in v3: remove the note regarding swapped clock names (now in a separate patch). Changes in v2: put new clock in last position (Rob Herring) Documentation/devicetree/bindings/display/st,stm32-ltdc.txt | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-)