@@ -214,6 +214,7 @@
interrupts = <27>;
clocks = <&soc_clocks MMP2_CLK_UART0>;
resets = <&soc_clocks MMP2_CLK_UART0>;
+ reg-shift = <2>;
status = "disabled";
};
@@ -223,6 +224,7 @@
interrupts = <28>;
clocks = <&soc_clocks MMP2_CLK_UART1>;
resets = <&soc_clocks MMP2_CLK_UART1>;
+ reg-shift = <2>;
status = "disabled";
};
@@ -232,6 +234,7 @@
interrupts = <24>;
clocks = <&soc_clocks MMP2_CLK_UART2>;
resets = <&soc_clocks MMP2_CLK_UART2>;
+ reg-shift = <2>;
status = "disabled";
};
@@ -241,6 +244,7 @@
interrupts = <46>;
clocks = <&soc_clocks MMP2_CLK_UART3>;
resets = <&soc_clocks MMP2_CLK_UART3>;
+ reg-shift = <2>;
status = "disabled";
};
This makes the 8250_of driver happy. There are two more drivers in the tree that bind to mrvl,mmp-uart compatibles: pxa and 8250_pxa and neither of them requires the reg-shift property, assuming it's always 2. Signed-off-by: Lubomir Rintel <lkundrak@v3.sk> --- Changes since v1: - Updated the subject to fit the style of the DTS updates --- arch/arm/boot/dts/mmp2.dtsi | 4 ++++ 1 file changed, 4 insertions(+)