new file mode 100644
@@ -0,0 +1,135 @@
+# SPDX-License-Identifier: GPL-2.0-only OR BSD-2-Clause
+# Copyright (c) 2023-2025 Qualcomm Innovation Center, Inc. All rights reserved.
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/arm/qcom,coresight-tgu.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Trigger Generation Unit - TGU
+
+description: |
+ The Trigger Generation Unit (TGU) is a Data Engine which can be utilized
+ to sense a plurality of signals and create a trigger into the CTI or
+ generate interrupts to processors. The TGU is like the trigger circuit
+ of a Logic Analyzer. The corresponding trigger logic can be realized by
+ configuring the conditions for each step after sensing the signal.
+ Once setup and enabled, it will observe sense inputs and based upon
+ the activity of those inputs, even over clock cycles, may detect a
+ preprogrammed state/sequence and then produce a trigger or interrupt.
+
+ The primary use case of the TGU is to detect patterns or sequences on a
+ given set of signals within some region of the SoC.
+
+maintainers:
+ - Mao Jinlong <quic_jinlmao@quicinc.com>
+ - Sam Chai <quic_songchai@quicinc.com>
+
+# Need a custom select here or 'arm,primecell' will match on lots of nodes
+select:
+ properties:
+ compatible:
+ contains:
+ enum:
+ - qcom,coresight-tgu
+ required:
+ - compatible
+
+properties:
+ compatible:
+ items:
+ - const: qcom,coresight-tgu
+ - const: arm,primecell
+
+ reg:
+ maxItems: 1
+
+ clocks:
+ maxItems: 1
+
+ clock-names:
+ items:
+ - const: apb_pclk
+
+ qcom,tgu-steps:
+ description:
+ The trigger logic is realized by configuring each step after sensing
+ the signal. The parameter here is used to describe the maximum of steps
+ that could be configured in the current TGU.
+ $ref: /schemas/types.yaml#/definitions/uint32
+ minimum: 1
+ maximum: 8
+
+ qcom,tgu-regs:
+ description:
+ There are some "groups" register clusters in each step, which are used to
+ configure the signal that we want to detect. Meanwhile, each group has its
+ own priority, and the priority increases with number of groups. For example,
+ group3 has a higher priority than group2, the signal configured in group3
+ will be sensed more preferentially than the signal which is configured in group2.
+ The parameter here is used to describe the signal number that each group
+ could be configured.
+ $ref: /schemas/types.yaml#/definitions/uint32
+ minimum: 1
+ maximum: 18
+
+ qcom,tgu-conditions:
+ description:
+ A condition sets a specific requirement for a step and defines the subsequent
+ action once the requirement is met. For example, in step two, if signal A is
+ detected three times, the process jumps back to step one. The parameter describes
+ the register number for each functionality, whether it is setting a specific
+ requirement or defining a subsequent action.
+ $ref: /schemas/types.yaml#/definitions/uint32
+ minimum: 1
+ maximum: 4
+
+ qcom,tgu-timer-counters:
+ description:
+ TGU has timer and counter which are used to set some requirement on each step.
+ For example, we could use counter to create a trigger into CTI once TGU senses
+ the target signal three times.This parameter is used to describe the number of
+ Timers/Counters in TGU.
+ $ref: /schemas/types.yaml#/definitions/uint32
+ minimum: 0
+ maximum: 2
+
+ in-ports:
+ $ref: /schemas/graph.yaml#/properties/ports
+ additionalProperties: false
+
+ properties:
+ port:
+ description: AXI Slave connected to another Coresight component
+ $ref: /schemas/graph.yaml#/properties/port
+
+required:
+ - compatible
+ - reg
+ - clocks
+ - clock-names
+
+additionalProperties: false
+
+examples:
+ - |
+ tgu@10b0e000 {
+ compatible = "qcom,coresight-tgu", "arm,primecell";
+ reg = <0x10b0e000 0x1000>;
+
+ clocks = <&aoss_qmp>;
+ clock-names = "apb_pclk";
+
+ qcom,tgu-steps = <3>;
+ qcom,tgu-regs = <4>;
+ qcom,tgu-conditions = <4>;
+ qcom,tgu-timer-counters = <1>;
+
+ in-ports {
+ port {
+ tgu_in_tpdm_swao: endpoint{
+ remote-endpoint = <&tpdm_swao_out_tgu>;
+ };
+ };
+ };
+ };
+...