@@ -318,7 +318,7 @@
/* VDD_MPU voltage limits 0.95V - 1.26V with +/-4% tolerance */
regulator-name = "vdd_mpu";
regulator-min-microvolt = <925000>;
- regulator-max-microvolt = <1325000>;
+ regulator-max-microvolt = <1351500>;
regulator-boot-on;
regulator-always-on;
};
@@ -640,7 +640,7 @@
/* VDD_MPU voltage limits 0.95V - 1.26V with +/-4% tolerance */
regulator-name = "vdd_mpu";
regulator-min-microvolt = <912500>;
- regulator-max-microvolt = <1312500>;
+ regulator-max-microvolt = <1351500>;
regulator-boot-on;
regulator-always-on;
};
@@ -560,7 +560,7 @@
/* VDD_MPU voltage limits 0.95V - 1.26V with +/-4% tolerance */
regulator-name = "vdd_mpu";
regulator-min-microvolt = <912500>;
- regulator-max-microvolt = <1312500>;
+ regulator-max-microvolt = <1351500>;
regulator-boot-on;
regulator-always-on;
};
Now that we are moving to OPPv2 bindings and able to add 1GHz OPP for MPU, let's update the max MPU voltage range to align with the maximum possible value allowed in the operating-points table, which is max target voltage of 132500 uV + 2%. Signed-off-by: Dave Gerlach <d-gerlach@ti.com> --- arch/arm/boot/dts/am335x-bone-common.dtsi | 2 +- arch/arm/boot/dts/am335x-evm.dts | 2 +- arch/arm/boot/dts/am335x-evmsk.dts | 2 +- 3 files changed, 3 insertions(+), 3 deletions(-)