diff mbox series

[08/10] arm64: dts: qcom: Fix IPQ8074 PCIe PHY nodes

Message ID 20210929034253.24570-9-shawn.guo@linaro.org (mailing list archive)
State Accepted
Headers show
Series Make Qualcomm QMP PHY dtbs_check warning free | expand

Commit Message

Shawn Guo Sept. 29, 2021, 3:42 a.m. UTC
IPQ8074 PCIe PHY nodes are broken in the many ways:

- '#address-cells', '#size-cells' and 'ranges' are missing.
- Child phy/lane node is missing, and the child properties like
  '#phy-cells' and 'clocks' are mistakenly put into parent node.
- The clocks properties for parent node are missing.

Fix them to get the nodes comply with the bindings schema.

Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
---
 arch/arm64/boot/dts/qcom/ipq8074.dtsi | 46 +++++++++++++++++++++------
 1 file changed, 36 insertions(+), 10 deletions(-)
diff mbox series

Patch

diff --git a/arch/arm64/boot/dts/qcom/ipq8074.dtsi b/arch/arm64/boot/dts/qcom/ipq8074.dtsi
index 2e4e1399e276..dfdd3e4a4087 100644
--- a/arch/arm64/boot/dts/qcom/ipq8074.dtsi
+++ b/arch/arm64/boot/dts/qcom/ipq8074.dtsi
@@ -174,34 +174,60 @@ 
 			status = "disabled";
 		};
 
-		pcie_phy0: phy@86000 {
+		pcie_qmp0: phy@86000 {
 			compatible = "qcom,ipq8074-qmp-pcie-phy";
 			reg = <0x00086000 0x1000>;
-			#phy-cells = <0>;
-			clocks = <&gcc GCC_PCIE0_PIPE_CLK>;
-			clock-names = "pipe_clk";
-			clock-output-names = "pcie20_phy0_pipe_clk";
+			#address-cells = <1>;
+			#size-cells = <1>;
+			ranges;
 
+			clocks = <&gcc GCC_PCIE0_AUX_CLK>,
+				<&gcc GCC_PCIE0_AHB_CLK>;
+			clock-names = "aux", "cfg_ahb";
 			resets = <&gcc GCC_PCIE0_PHY_BCR>,
 				<&gcc GCC_PCIE0PHY_PHY_BCR>;
 			reset-names = "phy",
 				      "common";
 			status = "disabled";
+
+			pcie_phy0: phy@86200 {
+				reg = <0x86200 0x16c>,
+				      <0x86400 0x200>,
+				      <0x86800 0x4f4>;
+				#phy-cells = <0>;
+				#clock-cells = <0>;
+				clocks = <&gcc GCC_PCIE0_PIPE_CLK>;
+				clock-names = "pipe0";
+				clock-output-names = "pcie_0_pipe_clk";
+			};
 		};
 
-		pcie_phy1: phy@8e000 {
+		pcie_qmp1: phy@8e000 {
 			compatible = "qcom,ipq8074-qmp-pcie-phy";
 			reg = <0x0008e000 0x1000>;
-			#phy-cells = <0>;
-			clocks = <&gcc GCC_PCIE1_PIPE_CLK>;
-			clock-names = "pipe_clk";
-			clock-output-names = "pcie20_phy1_pipe_clk";
+			#address-cells = <1>;
+			#size-cells = <1>;
+			ranges;
 
+			clocks = <&gcc GCC_PCIE1_AUX_CLK>,
+				<&gcc GCC_PCIE1_AHB_CLK>;
+			clock-names = "aux", "cfg_ahb";
 			resets = <&gcc GCC_PCIE1_PHY_BCR>,
 				<&gcc GCC_PCIE1PHY_PHY_BCR>;
 			reset-names = "phy",
 				      "common";
 			status = "disabled";
+
+			pcie_phy1: phy@8e200 {
+				reg = <0x8e200 0x16c>,
+				      <0x8e400 0x200>,
+				      <0x8e800 0x4f4>;
+				#phy-cells = <0>;
+				#clock-cells = <0>;
+				clocks = <&gcc GCC_PCIE1_PIPE_CLK>;
+				clock-names = "pipe0";
+				clock-output-names = "pcie_1_pipe_clk";
+			};
 		};
 
 		prng: rng@e3000 {