Series | [V2,1/2] dt-bindings: clk: versaclock5: Add optional load capacitance property | expand |
Hi Adam, On 19/01/21 22:21, Adam Ford wrote: > There are two registers which can set the load capacitance for > XTAL1 and XTAL2. These are optional registers when using an > external crystal. Since XTAL1 and XTAL2 will set to the same value, > update the binding to support a single property called > xtal-load-femtofarads. > > Signed-off-by: Adam Ford <aford173@gmail.com> > --- > V2: No Change > > diff --git a/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml b/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml > index 2ac1131fd922..c268debe5b8d 100644 > --- a/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml > +++ b/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml > @@ -59,6 +59,12 @@ properties: > minItems: 1 > maxItems: 2 > > + idt,xtal-load-femtofarads: > + $ref: /schemas/types.yaml#/definitions/uint32 "Vendor specific properties having a standard unit suffix don't need a type." -- Documentation/devicetree/bindings/example-schema.yaml Overall looks good.
On Wed, Jan 20, 2021 at 10:35 AM Luca Ceresoli <luca@lucaceresoli.net> wrote: > > Hi Adam, > > On 19/01/21 22:21, Adam Ford wrote: > > There are two registers which can set the load capacitance for > > XTAL1 and XTAL2. These are optional registers when using an > > external crystal. Since XTAL1 and XTAL2 will set to the same value, > > update the binding to support a single property called > > xtal-load-femtofarads. > > > > Signed-off-by: Adam Ford <aford173@gmail.com> > > --- > > V2: No Change > > > > diff --git a/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml b/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml > > index 2ac1131fd922..c268debe5b8d 100644 > > --- a/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml > > +++ b/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml > > @@ -59,6 +59,12 @@ properties: > > minItems: 1 > > maxItems: 2 > > > > + idt,xtal-load-femtofarads: > > + $ref: /schemas/types.yaml#/definitions/uint32 > > "Vendor specific properties having a standard unit suffix don't need a > type." -- Documentation/devicetree/bindings/example-schema.yaml > I tried to remove the "$ref: /schemas/types.yaml#/definitions/uint32" but when I ran the test to make the yaml files, it threw an error, so I put it back. adam > Overall looks good. > > -- > Luca
diff --git a/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml b/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml index 2ac1131fd922..c268debe5b8d 100644 --- a/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml +++ b/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml @@ -59,6 +59,12 @@ properties: minItems: 1 maxItems: 2 + idt,xtal-load-femtofarads: + $ref: /schemas/types.yaml#/definitions/uint32 + minimum: 9000 + maximum: 22760 + description: Optional load capacitor for XTAL1 and XTAL2 + patternProperties: "^OUT[1-4]$": type: object
There are two registers which can set the load capacitance for XTAL1 and XTAL2. These are optional registers when using an external crystal. Since XTAL1 and XTAL2 will set to the same value, update the binding to support a single property called xtal-load-femtofarads. Signed-off-by: Adam Ford <aford173@gmail.com> --- V2: No Change