diff mbox series

[2/3] arm64: dts: meson: add S4 Soc clock controller in DT

Message ID 20220708062757.3662-3-yu.tu@amlogic.com (mailing list archive)
State Not Applicable, archived
Headers show
Series Add S4 SoC clock controller driver | expand

Commit Message

Yu Tu July 8, 2022, 6:27 a.m. UTC
Added information about the S4 SOC Clock controller in DT.

Signed-off-by: Yu Tu <yu.tu@amlogic.com>
---
 arch/arm64/boot/dts/amlogic/meson-s4.dtsi | 9 ++++++++-
 1 file changed, 8 insertions(+), 1 deletion(-)

Comments

Krzysztof Kozlowski July 12, 2022, 9:41 a.m. UTC | #1
On 08/07/2022 08:27, Yu Tu wrote:
> Added information about the S4 SOC Clock controller in DT.
> 
> Signed-off-by: Yu Tu <yu.tu@amlogic.com>
> ---
>  arch/arm64/boot/dts/amlogic/meson-s4.dtsi | 9 ++++++++-
>  1 file changed, 8 insertions(+), 1 deletion(-)
> 
> diff --git a/arch/arm64/boot/dts/amlogic/meson-s4.dtsi b/arch/arm64/boot/dts/amlogic/meson-s4.dtsi
> index ff213618a598..ad2ec26a1f4a 100644
> --- a/arch/arm64/boot/dts/amlogic/meson-s4.dtsi
> +++ b/arch/arm64/boot/dts/amlogic/meson-s4.dtsi
> @@ -86,7 +86,7 @@ gic: interrupt-controller@fff01000 {
>  		};
>  
>  		apb4: apb4@fe000000 {
> -			compatible = "simple-bus";
> +			compatible = "simple-bus", "syscon";

This is not allowed.
1. syscon needs also dedicated compatible
2. simple-bus with syscon means it is not a simple bus anymore, so nope.

>  			reg = <0x0 0xfe000000 0x0 0x480000>;
>  			#address-cells = <2>;
>  			#size-cells = <2>;
> @@ -118,6 +118,13 @@ gpio_intc: interrupt-controller@4080 {
>  					<10 11 12 13 14 15 16 17 18 19 20 21>;
>  			};
>  
> +			clkc: clock-controller {
> +				compatible = "amlogic,s4-clkc";
> +				#clock-cells = <1>;
> +				clocks = <&xtal>;
> +				clock-names = "xtal";
> +			};
> +
>  			uart_B: serial@7a000 {
>  				compatible = "amlogic,meson-s4-uart",
>  					     "amlogic,meson-ao-uart";


Best regards,
Krzysztof
Yu Tu July 19, 2022, 5:57 a.m. UTC | #2
Hi Krzysztof,
	Thank you for your advice.

On 2022/7/12 17:41, Krzysztof Kozlowski wrote:
> [ EXTERNAL EMAIL ]
> 
> On 08/07/2022 08:27, Yu Tu wrote:
>> Added information about the S4 SOC Clock controller in DT.
>>
>> Signed-off-by: Yu Tu <yu.tu@amlogic.com>
>> ---
>>   arch/arm64/boot/dts/amlogic/meson-s4.dtsi | 9 ++++++++-
>>   1 file changed, 8 insertions(+), 1 deletion(-)
>>
>> diff --git a/arch/arm64/boot/dts/amlogic/meson-s4.dtsi b/arch/arm64/boot/dts/amlogic/meson-s4.dtsi
>> index ff213618a598..ad2ec26a1f4a 100644
>> --- a/arch/arm64/boot/dts/amlogic/meson-s4.dtsi
>> +++ b/arch/arm64/boot/dts/amlogic/meson-s4.dtsi
>> @@ -86,7 +86,7 @@ gic: interrupt-controller@fff01000 {
>>   		};
>>   
>>   		apb4: apb4@fe000000 {
>> -			compatible = "simple-bus";
>> +			compatible = "simple-bus", "syscon";
> 
> This is not allowed.
> 1. syscon needs also dedicated compatible
> 2. simple-bus with syscon means it is not a simple bus anymore, so nope.
I will correct it.
> 
>>   			reg = <0x0 0xfe000000 0x0 0x480000>;
>>   			#address-cells = <2>;
>>   			#size-cells = <2>;
>> @@ -118,6 +118,13 @@ gpio_intc: interrupt-controller@4080 {
>>   					<10 11 12 13 14 15 16 17 18 19 20 21>;
>>   			};
>>   
>> +			clkc: clock-controller {
>> +				compatible = "amlogic,s4-clkc";
>> +				#clock-cells = <1>;
>> +				clocks = <&xtal>;
>> +				clock-names = "xtal";
>> +			};
>> +
>>   			uart_B: serial@7a000 {
>>   				compatible = "amlogic,meson-s4-uart",
>>   					     "amlogic,meson-ao-uart";
> 
> 
> Best regards,
> Krzysztof
> 
> .
diff mbox series

Patch

diff --git a/arch/arm64/boot/dts/amlogic/meson-s4.dtsi b/arch/arm64/boot/dts/amlogic/meson-s4.dtsi
index ff213618a598..ad2ec26a1f4a 100644
--- a/arch/arm64/boot/dts/amlogic/meson-s4.dtsi
+++ b/arch/arm64/boot/dts/amlogic/meson-s4.dtsi
@@ -86,7 +86,7 @@  gic: interrupt-controller@fff01000 {
 		};
 
 		apb4: apb4@fe000000 {
-			compatible = "simple-bus";
+			compatible = "simple-bus", "syscon";
 			reg = <0x0 0xfe000000 0x0 0x480000>;
 			#address-cells = <2>;
 			#size-cells = <2>;
@@ -118,6 +118,13 @@  gpio_intc: interrupt-controller@4080 {
 					<10 11 12 13 14 15 16 17 18 19 20 21>;
 			};
 
+			clkc: clock-controller {
+				compatible = "amlogic,s4-clkc";
+				#clock-cells = <1>;
+				clocks = <&xtal>;
+				clock-names = "xtal";
+			};
+
 			uart_B: serial@7a000 {
 				compatible = "amlogic,meson-s4-uart",
 					     "amlogic,meson-ao-uart";