@@ -77,6 +77,7 @@ static inline unsigned int IN_FROM_REG(u8 reg, int n)
static inline u8 IN_TO_REG(unsigned long val, int n)
{
+ val = clamp_val(val, 0, 65535);
return clamp_val(SCALE(val, 192, nom_mv[n]), 0, 255);
}
@@ -84,7 +85,7 @@ static inline u8 IN_TO_REG(unsigned long val, int n)
* TEMP: 0.001 degC units (-128C to +127C)
* REG: 1C/bit, two's complement
*/
-static inline s8 TEMP_TO_REG(int val)
+static inline s8 TEMP_TO_REG(long val)
{
return SCALE(clamp_val(val, -128000, 127000), 1, 1000);
}
Module test reports overflows when writing into temperature and voltage limit attributes temp1_min: Suspected overflow: [127000 vs. 0] temp1_max: Suspected overflow: [127000 vs. 0] temp1_offset: Suspected overflow: [127000 vs. 0] temp2_min: Suspected overflow: [127000 vs. 0] temp2_max: Suspected overflow: [127000 vs. 0] temp2_offset: Suspected overflow: [127000 vs. 0] temp3_min: Suspected overflow: [127000 vs. 0] temp3_max: Suspected overflow: [127000 vs. 0] temp3_offset: Suspected overflow: [127000 vs. 0] in0_min: Suspected overflow: [3320 vs. 0] in0_max: Suspected overflow: [3320 vs. 0] in4_min: Suspected overflow: [15938 vs. 0] in4_max: Suspected overflow: [15938 vs. 0] in6_min: Suspected overflow: [1992 vs. 0] in6_max: Suspected overflow: [1992 vs. 0] in7_min: Suspected overflow: [2391 vs. 0] in7_max: Suspected overflow: [2391 vs. 0] The problem is caused by conversions from unsigned long to long and from long to int. Signed-off-by: Guenter Roeck <linux@roeck-us.net> --- drivers/hwmon/smsc47m192.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)