@@ -34,7 +34,7 @@ static int int340x_thermal_get_zone_temp(struct thermal_zone_device *zone,
*temp = (unsigned long)conv_temp * 10;
} else
/* _TMP returns the temperature in tenths of degrees Kelvin */
- *temp = DECI_KELVIN_TO_MILLICELSIUS(tmp);
+ *temp = deci_kelvin_to_millicelsius(tmp);
return 0;
}
@@ -116,7 +116,7 @@ static int int340x_thermal_set_trip_temp(struct thermal_zone_device *zone,
snprintf(name, sizeof(name), "PAT%d", trip);
status = acpi_execute_simple_method(d->adev->handle, name,
- MILLICELSIUS_TO_DECI_KELVIN(temp));
+ millicelsius_to_deci_kelvin(temp));
if (ACPI_FAILURE(status))
return -EIO;
@@ -163,7 +163,7 @@ static int int340x_thermal_get_trip_config(acpi_handle handle, char *name,
if (ACPI_FAILURE(status))
return -EIO;
- *temp = DECI_KELVIN_TO_MILLICELSIUS(r);
+ *temp = deci_kelvin_to_millicelsius(r);
return 0;
}
This switches the int340x thermal zone driver to use deci_kelvin_to_millicelsius() and millicelsius_to_deci_kelvin() in <linux/temperature.h> instead of helpers in <linux/thermal.h>. This is preparation for centralizing the kelvin to/from Celsius conversion helpers in <linux/temprature.h>. Cc: Sujith Thomas <sujith.thomas@intel.com> Cc: Darren Hart <dvhart@infradead.org> Cc: Andy Shevchenko <andy@infradead.org> Cc: Zhang Rui <rui.zhang@intel.com> Cc: Eduardo Valentin <edubezval@gmail.com> Cc: Daniel Lezcano <daniel.lezcano@linaro.org> Cc: Amit Kucheria <amit.kucheria@verdurent.com> Cc: Jean Delvare <jdelvare@suse.com> Cc: Guenter Roeck <linux@roeck-us.net> Cc: Keith Busch <kbusch@kernel.org> Cc: Jens Axboe <axboe@fb.com> Cc: Christoph Hellwig <hch@lst.de> Cc: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Akinobu Mita <akinobu.mita@gmail.com> --- drivers/thermal/intel/int340x_thermal/int340x_thermal_zone.c | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-)