Naveen Krishna Chatradhi Sept. 29, 2020, 10:53 a.m. UTC
On a system with course grain resolution of energy unit (milli J) the
accumulation thread can be executed less frequently than on the system
with fine grain resolution(micro J).

This patch sets the accumulation thread interval to an optimum value
calculated based on the (energy unit) resolution supported by the
hardware (assuming a peak wattage of 240W).

Signed-off-by: Naveen Krishna Chatradhi <nchatrad@amd.com>
---
Changes since v1:
1. Generalized formula as suggested by Guenter.
2. Use milli seconds for interval

 drivers/hwmon/amd_energy.c | 20 +++++++++++---------
 1 file changed, 11 insertions(+), 9 deletions(-)
diff mbox series

Patch

diff --git a/drivers/hwmon/amd_energy.c b/drivers/hwmon/amd_energy.c
index 9580a16185b8..c413adfc6a73 100644
--- a/drivers/hwmon/amd_energy.c
+++ b/drivers/hwmon/amd_energy.c
@@ -46,8 +46,9 @@  struct amd_energy_data {
 	struct mutex lock;
 	/* An accumulator for each core and socket */
 	struct sensor_accumulator *accums;
+	unsigned int timeout_ms;
 	/* Energy Status Units */
-	u64 energy_units;
+	int energy_units;
 	int nr_cpus;
 	int nr_socks;
 	int core_id;
@@ -215,6 +216,7 @@  static umode_t amd_energy_is_visible(const void *_data,
 static int energy_accumulator(void *p)
 {
 	struct amd_energy_data *data = (struct amd_energy_data *)p;
+	unsigned int timeout = data->timeout_ms;
 
 	while (!kthread_should_stop()) {
 		/*
@@ -227,14 +229,7 @@  static int energy_accumulator(void *p)
 		if (kthread_should_stop())
 			break;
 
-		/*
-		 * On a 240W system, with default resolution the
-		 * Socket Energy status register may wrap around in
-		 * 2^32*15.3 e-6/240 = 273.8041 secs (~4.5 mins)
-		 *
-		 * let us accumulate for every 100secs
-		 */
-		schedule_timeout(msecs_to_jiffies(100000));
+		schedule_timeout(msecs_to_jiffies(timeout));
 	}
 	return 0;
 }
@@ -331,6 +326,13 @@  static int amd_energy_probe(struct platform_device *pdev)
 	if (IS_ERR(hwmon_dev))
 		return PTR_ERR(hwmon_dev);
 
+	/*
+	 * On a system with peak wattage of 250W
+	 * timeout = 2 ^ 32 / 2 ^ energy_units / 250 secs
+	 */
+	data->timeout_ms = 1000 *
+			   BIT(min(28, 31 - data->energy_units)) / 250;
+
 	data->wrap_accumulate = kthread_run(energy_accumulator, data,
 					    "%s", dev_name(hwmon_dev));