diff mbox series

hwmon: (aquacomputer_d5next) Add support for Aquacomputer Leakshield

Message ID 20230516164213.7938-1-savicaleksa83@gmail.com (mailing list archive)
State Changes Requested
Headers show
Series hwmon: (aquacomputer_d5next) Add support for Aquacomputer Leakshield | expand

Commit Message

Aleksa Savic May 16, 2023, 4:42 p.m. UTC
Extend aquacomputer_d5next driver to expose various hardware sensors of the
Aquacomputer Leakshield leak prevention system, which communicates
through a proprietary USB HID protocol. Implemented by Noah Bergbauer [1].

Two temperature sensors are exposed, along with pressure (current, min, max
and target), reservoir volume (total and filled), pump speed and flow. Pump
speed and flow values are user provided and allow the Leakshield to
optimize its operation. Writing them to the device is subject of future
patches.

[1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/41

Originally-from: Noah Bergbauer <main@ehvag.de>
Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
---
 Documentation/hwmon/aquacomputer_d5next.rst |   9 ++
 drivers/hwmon/aquacomputer_d5next.c         | 117 ++++++++++++++++++--
 2 files changed, 118 insertions(+), 8 deletions(-)

Comments

Guenter Roeck May 19, 2023, 12:56 p.m. UTC | #1
On Tue, May 16, 2023 at 06:42:13PM +0200, Aleksa Savic wrote:
> Extend aquacomputer_d5next driver to expose various hardware sensors of the
> Aquacomputer Leakshield leak prevention system, which communicates
> through a proprietary USB HID protocol. Implemented by Noah Bergbauer [1].
> 
> Two temperature sensors are exposed, along with pressure (current, min, max
> and target), reservoir volume (total and filled), pump speed and flow. Pump
> speed and flow values are user provided and allow the Leakshield to
> optimize its operation. Writing them to the device is subject of future
> patches.
> 
> [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/41
> 
> Originally-from: Noah Bergbauer <main@ehvag.de>
> Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
> ---
>  Documentation/hwmon/aquacomputer_d5next.rst |   9 ++
>  drivers/hwmon/aquacomputer_d5next.c         | 117 ++++++++++++++++++--
>  2 files changed, 118 insertions(+), 8 deletions(-)
> 
> diff --git a/Documentation/hwmon/aquacomputer_d5next.rst b/Documentation/hwmon/aquacomputer_d5next.rst
> index 14b37851af0c..94dc2d93d180 100644
> --- a/Documentation/hwmon/aquacomputer_d5next.rst
> +++ b/Documentation/hwmon/aquacomputer_d5next.rst
> @@ -12,6 +12,7 @@ Supported devices:
>  * Aquacomputer Octo fan controller
>  * Aquacomputer Quadro fan controller
>  * Aquacomputer High Flow Next sensor
> +* Aquacomputer Leakshield leak prevention system
>  * Aquacomputer Aquastream XT watercooling pump
>  * Aquacomputer Aquastream Ultimate watercooling pump
>  * Aquacomputer Poweradjust 3 fan controller
> @@ -57,6 +58,11 @@ The High Flow Next exposes +5V voltages, water quality, conductivity and flow re
>  A temperature sensor can be connected to it, in which case it provides its reading
>  and an estimation of the dissipated/absorbed power in the liquid cooling loop.
>  
> +The Leakshield exposes two temperature sensors and coolant pressure (current, min, max and
> +target readings). It also exposes the estimated reservoir volume and how much of it is
> +filled with coolant. Pump RPM and flow can be set to enhance on-device calculations,
> +but this is not yet implemented here.
> +
>  The Aquastream XT pump exposes temperature readings for the coolant, external sensor
>  and fan IC. It also exposes pump and fan speeds (in RPM), voltages, as well as pump
>  current.
> @@ -83,6 +89,9 @@ Sysfs entries
>  temp[1-20]_input Physical/virtual temperature sensors (in millidegrees Celsius)
>  temp[1-8]_offset Temperature sensor correction offset (in millidegrees Celsius)
>  fan[1-8]_input   Pump/fan speed (in RPM) / Flow speed (in dL/h)
> +fan1_min         Minimal fan speed (in RPM)
> +fan1_max         Maximal fan speed (in RPM)
> +fan1_target      Target fan speed (in RPM)
>  fan5_pulses      Quadro flow sensor pulses
>  power[1-8]_input Pump/fan power (in micro Watts)
>  in[0-7]_input    Pump/fan voltage (in milli Volts)
> diff --git a/drivers/hwmon/aquacomputer_d5next.c b/drivers/hwmon/aquacomputer_d5next.c
> index a4fcd4ebf76c..a981f7086114 100644
> --- a/drivers/hwmon/aquacomputer_d5next.c
> +++ b/drivers/hwmon/aquacomputer_d5next.c
> @@ -1,7 +1,7 @@
>  // SPDX-License-Identifier: GPL-2.0+
>  /*
>   * hwmon driver for Aquacomputer devices (D5 Next, Farbwerk, Farbwerk 360, Octo,
> - * Quadro, High Flow Next, Aquaero, Aquastream Ultimate)
> + * Quadro, High Flow Next, Aquaero, Aquastream Ultimate, Leakshield)
>   *
>   * Aquacomputer devices send HID reports (with ID 0x01) every second to report
>   * sensor values, except for devices that communicate through the
> @@ -29,6 +29,7 @@
>  #define USB_PRODUCT_ID_FARBWERK360	0xf010
>  #define USB_PRODUCT_ID_OCTO		0xf011
>  #define USB_PRODUCT_ID_HIGHFLOWNEXT	0xf012
> +#define USB_PRODUCT_ID_LEAKSHIELD	0xf014
>  #define USB_PRODUCT_ID_AQUASTREAMXT	0xf0b6
>  #define USB_PRODUCT_ID_AQUASTREAMULT	0xf00b
>  #define USB_PRODUCT_ID_POWERADJUST3	0xf0bd
> @@ -36,7 +37,7 @@
>  enum kinds {
>  	d5next, farbwerk, farbwerk360, octo, quadro,
>  	highflownext, aquaero, poweradjust3, aquastreamult,
> -	aquastreamxt
> +	aquastreamxt, leakshield
>  };
>  
>  static const char *const aqc_device_names[] = {
> @@ -46,6 +47,7 @@ static const char *const aqc_device_names[] = {
>  	[octo] = "octo",
>  	[quadro] = "quadro",
>  	[highflownext] = "highflownext",
> +	[leakshield] = "leakshield",
>  	[aquastreamxt] = "aquastreamxt",
>  	[aquaero] = "aquaero",
>  	[aquastreamult] = "aquastreamultimate",
> @@ -93,7 +95,7 @@ static u8 aquaero_secondary_ctrl_report[] = {
>  #define AQC_FIRMWARE_VERSION		0xD
>  
>  #define AQC_SENSOR_SIZE			0x02
> -#define AQC_TEMP_SENSOR_DISCONNECTED	0x7FFF
> +#define AQC_SENSOR_NA			0x7FFF

This would have to be a separate change.

Guenter
Aleksa Savic May 19, 2023, 2:02 p.m. UTC | #2
On 2023-05-19 14:56:24 GMT+02:00, Guenter Roeck wrote:
> 
> This would have to be a separate change.
> 
> Guenter

Will move into separate patch, thanks.

Aleksa
diff mbox series

Patch

diff --git a/Documentation/hwmon/aquacomputer_d5next.rst b/Documentation/hwmon/aquacomputer_d5next.rst
index 14b37851af0c..94dc2d93d180 100644
--- a/Documentation/hwmon/aquacomputer_d5next.rst
+++ b/Documentation/hwmon/aquacomputer_d5next.rst
@@ -12,6 +12,7 @@  Supported devices:
 * Aquacomputer Octo fan controller
 * Aquacomputer Quadro fan controller
 * Aquacomputer High Flow Next sensor
+* Aquacomputer Leakshield leak prevention system
 * Aquacomputer Aquastream XT watercooling pump
 * Aquacomputer Aquastream Ultimate watercooling pump
 * Aquacomputer Poweradjust 3 fan controller
@@ -57,6 +58,11 @@  The High Flow Next exposes +5V voltages, water quality, conductivity and flow re
 A temperature sensor can be connected to it, in which case it provides its reading
 and an estimation of the dissipated/absorbed power in the liquid cooling loop.
 
+The Leakshield exposes two temperature sensors and coolant pressure (current, min, max and
+target readings). It also exposes the estimated reservoir volume and how much of it is
+filled with coolant. Pump RPM and flow can be set to enhance on-device calculations,
+but this is not yet implemented here.
+
 The Aquastream XT pump exposes temperature readings for the coolant, external sensor
 and fan IC. It also exposes pump and fan speeds (in RPM), voltages, as well as pump
 current.
@@ -83,6 +89,9 @@  Sysfs entries
 temp[1-20]_input Physical/virtual temperature sensors (in millidegrees Celsius)
 temp[1-8]_offset Temperature sensor correction offset (in millidegrees Celsius)
 fan[1-8]_input   Pump/fan speed (in RPM) / Flow speed (in dL/h)
+fan1_min         Minimal fan speed (in RPM)
+fan1_max         Maximal fan speed (in RPM)
+fan1_target      Target fan speed (in RPM)
 fan5_pulses      Quadro flow sensor pulses
 power[1-8]_input Pump/fan power (in micro Watts)
 in[0-7]_input    Pump/fan voltage (in milli Volts)
diff --git a/drivers/hwmon/aquacomputer_d5next.c b/drivers/hwmon/aquacomputer_d5next.c
index a4fcd4ebf76c..a981f7086114 100644
--- a/drivers/hwmon/aquacomputer_d5next.c
+++ b/drivers/hwmon/aquacomputer_d5next.c
@@ -1,7 +1,7 @@ 
 // SPDX-License-Identifier: GPL-2.0+
 /*
  * hwmon driver for Aquacomputer devices (D5 Next, Farbwerk, Farbwerk 360, Octo,
- * Quadro, High Flow Next, Aquaero, Aquastream Ultimate)
+ * Quadro, High Flow Next, Aquaero, Aquastream Ultimate, Leakshield)
  *
  * Aquacomputer devices send HID reports (with ID 0x01) every second to report
  * sensor values, except for devices that communicate through the
@@ -29,6 +29,7 @@ 
 #define USB_PRODUCT_ID_FARBWERK360	0xf010
 #define USB_PRODUCT_ID_OCTO		0xf011
 #define USB_PRODUCT_ID_HIGHFLOWNEXT	0xf012
+#define USB_PRODUCT_ID_LEAKSHIELD	0xf014
 #define USB_PRODUCT_ID_AQUASTREAMXT	0xf0b6
 #define USB_PRODUCT_ID_AQUASTREAMULT	0xf00b
 #define USB_PRODUCT_ID_POWERADJUST3	0xf0bd
@@ -36,7 +37,7 @@ 
 enum kinds {
 	d5next, farbwerk, farbwerk360, octo, quadro,
 	highflownext, aquaero, poweradjust3, aquastreamult,
-	aquastreamxt
+	aquastreamxt, leakshield
 };
 
 static const char *const aqc_device_names[] = {
@@ -46,6 +47,7 @@  static const char *const aqc_device_names[] = {
 	[octo] = "octo",
 	[quadro] = "quadro",
 	[highflownext] = "highflownext",
+	[leakshield] = "leakshield",
 	[aquastreamxt] = "aquastreamxt",
 	[aquaero] = "aquaero",
 	[aquastreamult] = "aquastreamultimate",
@@ -93,7 +95,7 @@  static u8 aquaero_secondary_ctrl_report[] = {
 #define AQC_FIRMWARE_VERSION		0xD
 
 #define AQC_SENSOR_SIZE			0x02
-#define AQC_TEMP_SENSOR_DISCONNECTED	0x7FFF
+#define AQC_SENSOR_NA			0x7FFF
 #define AQC_FAN_PERCENT_OFFSET		0x00
 #define AQC_FAN_VOLTAGE_OFFSET		0x02
 #define AQC_FAN_CURRENT_OFFSET		0x04
@@ -236,6 +238,21 @@  static u16 quadro_ctrl_fan_offsets[] = { 0x37, 0x8c, 0xe1, 0x136 }; /* Fan speed
 #define HIGHFLOWNEXT_5V_VOLTAGE		97
 #define HIGHFLOWNEXT_5V_VOLTAGE_USB	99
 
+/* Specs of the Leakshield */
+#define LEAKSHIELD_NUM_SENSORS		2
+
+/* Sensor report offsets for Leakshield */
+#define LEAKSHIELD_PRESSURE_ADJUSTED	285
+#define LEAKSHIELD_TEMPERATURE_1	265
+#define LEAKSHIELD_TEMPERATURE_2	287
+#define LEAKSHIELD_PRESSURE_MIN		291
+#define LEAKSHIELD_PRESSURE_TARGET	293
+#define LEAKSHIELD_PRESSURE_MAX		295
+#define LEAKSHIELD_PUMP_RPM_IN		101
+#define LEAKSHIELD_FLOW_IN		111
+#define LEAKSHIELD_RESERVOIR_VOLUME	313
+#define LEAKSHIELD_RESERVOIR_FILLED	311
+
 /* Specs of the Aquastream XT pump */
 #define AQUASTREAMXT_SERIAL_START		0x3a
 #define AQUASTREAMXT_FIRMWARE_VERSION		0x32
@@ -411,6 +428,20 @@  static const char *const label_highflownext_voltage[] = {
 	"+5V USB voltage"
 };
 
+/* Labels for Leakshield */
+static const char *const label_leakshield_temp_sensors[] = {
+	"Temperature 1",
+	"Temperature 2"
+};
+
+static const char *const label_leakshield_fan_speed[] = {
+	"Pressure [ubar]",
+	"User-Provided Pump Speed",
+	"User-Provided Flow [dL/h]",
+	"Reservoir Volume [ml]",
+	"Reservoir Filled [ml]",
+};
+
 /* Labels for Aquastream XT */
 static const char *const label_aquastreamxt_temp_sensors[] = {
 	"Fan IC temp",
@@ -529,7 +560,10 @@  struct aqc_data {
 
 	/* Sensor values */
 	s32 temp_input[20];	/* Max 4 physical and 16 virtual or 8 physical and 12 virtual */
-	u16 speed_input[8];
+	s32 speed_input[8];
+	u32 speed_input_min[1];
+	u32 speed_input_target[1];
+	u32 speed_input_max[1];
 	u32 power_input[8];
 	u16 voltage_input[8];
 	u16 current_input[8];
@@ -747,6 +781,11 @@  static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3
 				if (channel < 3)
 					return 0444;
 				break;
+			case leakshield:
+				/* Special case for Leakshield sensors */
+				if (channel < 5)
+					return 0444;
+				break;
 			case aquaero:
 			case quadro:
 				/* Special case to support flow sensors */
@@ -764,6 +803,13 @@  static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3
 			if (priv->kind == quadro && channel == priv->num_fans)
 				return 0644;
 			break;
+		case hwmon_fan_min:
+		case hwmon_fan_max:
+		case hwmon_fan_target:
+			/* Special case for Leakshield pressure sensor */
+			if (priv->kind == leakshield && channel == 0)
+				return 0444;
+			break;
 		default:
 			break;
 		}
@@ -938,8 +984,20 @@  static int aqc_read(struct device *dev, enum hwmon_sensor_types type, u32 attr,
 	case hwmon_fan:
 		switch (attr) {
 		case hwmon_fan_input:
+			if (priv->speed_input[channel] == -ENODATA)
+				return -ENODATA;
+
 			*val = priv->speed_input[channel];
 			break;
+		case hwmon_fan_min:
+			*val = priv->speed_input_min[channel];
+			break;
+		case hwmon_fan_max:
+			*val = priv->speed_input_max[channel];
+			break;
+		case hwmon_fan_target:
+			*val = priv->speed_input_target[channel];
+			break;
 		case hwmon_fan_pulses:
 			ret = aqc_get_ctrl_val(priv, priv->flow_pulses_ctrl_offset,
 					       val, AQC_BE16);
@@ -1151,7 +1209,8 @@  static const struct hwmon_channel_info * const aqc_info[] = {
 			   HWMON_T_INPUT | HWMON_T_LABEL,
 			   HWMON_T_INPUT | HWMON_T_LABEL),
 	HWMON_CHANNEL_INFO(fan,
-			   HWMON_F_INPUT | HWMON_F_LABEL,
+			   HWMON_F_INPUT | HWMON_F_LABEL | HWMON_F_MIN | HWMON_F_MAX |
+			   HWMON_F_TARGET,
 			   HWMON_F_INPUT | HWMON_F_LABEL,
 			   HWMON_F_INPUT | HWMON_F_LABEL,
 			   HWMON_F_INPUT | HWMON_F_LABEL,
@@ -1224,7 +1283,7 @@  static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8
 		sensor_value = get_unaligned_be16(data +
 						  priv->temp_sensor_start_offset +
 						  i * AQC_SENSOR_SIZE);
-		if (sensor_value == AQC_TEMP_SENSOR_DISCONNECTED)
+		if (sensor_value == AQC_SENSOR_NA)
 			priv->temp_input[i] = -ENODATA;
 		else
 			priv->temp_input[i] = sensor_value * 10;
@@ -1235,7 +1294,7 @@  static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8
 		sensor_value = get_unaligned_be16(data +
 						  priv->virtual_temp_sensor_start_offset +
 						  j * AQC_SENSOR_SIZE);
-		if (sensor_value == AQC_TEMP_SENSOR_DISCONNECTED)
+		if (sensor_value == AQC_SENSOR_NA)
 			priv->temp_input[i] = -ENODATA;
 		else
 			priv->temp_input[i] = sensor_value * 10;
@@ -1277,7 +1336,7 @@  static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8
 			sensor_value = get_unaligned_be16(data +
 					priv->calc_virt_temp_sensor_start_offset +
 					j * AQC_SENSOR_SIZE);
-			if (sensor_value == AQC_TEMP_SENSOR_DISCONNECTED)
+			if (sensor_value == AQC_SENSOR_NA)
 				priv->temp_input[i] = -ENODATA;
 			else
 				priv->temp_input[i] = sensor_value * 10;
@@ -1314,6 +1373,28 @@  static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8
 		priv->speed_input[1] = get_unaligned_be16(data + HIGHFLOWNEXT_WATER_QUALITY);
 		priv->speed_input[2] = get_unaligned_be16(data + HIGHFLOWNEXT_CONDUCTIVITY);
 		break;
+	case leakshield:
+		priv->speed_input[0] =
+		    ((s16)get_unaligned_be16(data + LEAKSHIELD_PRESSURE_ADJUSTED)) * 100;
+		priv->speed_input_min[0] = get_unaligned_be16(data + LEAKSHIELD_PRESSURE_MIN) * 100;
+		priv->speed_input_target[0] =
+		    get_unaligned_be16(data + LEAKSHIELD_PRESSURE_TARGET) * 100;
+		priv->speed_input_max[0] = get_unaligned_be16(data + LEAKSHIELD_PRESSURE_MAX) * 100;
+
+		priv->speed_input[1] = get_unaligned_be16(data + LEAKSHIELD_PUMP_RPM_IN);
+		if (priv->speed_input[1] == AQC_SENSOR_NA)
+			priv->speed_input[1] = -ENODATA;
+
+		priv->speed_input[2] = get_unaligned_be16(data + LEAKSHIELD_FLOW_IN);
+		if (priv->speed_input[2] == AQC_SENSOR_NA)
+			priv->speed_input[2] = -ENODATA;
+
+		priv->speed_input[3] = get_unaligned_be16(data + LEAKSHIELD_RESERVOIR_VOLUME);
+		priv->speed_input[4] = get_unaligned_be16(data + LEAKSHIELD_RESERVOIR_FILLED);
+
+		/* Second temp sensor is not positioned after the first one, read it here */
+		priv->temp_input[1] = get_unaligned_be16(data + LEAKSHIELD_TEMPERATURE_2) * 10;
+		break;
 	default:
 		break;
 	}
@@ -1571,6 +1652,25 @@  static int aqc_probe(struct hid_device *hdev, const struct hid_device_id *id)
 		priv->power_label = label_highflownext_power;
 		priv->voltage_label = label_highflownext_voltage;
 		break;
+	case USB_PRODUCT_ID_LEAKSHIELD:
+		/*
+		 * Choose the right Leakshield device, because
+		 * the other one acts as a keyboard
+		 */
+		if (hdev->type != 2) {
+			ret = -ENODEV;
+			goto fail_and_close;
+		}
+
+		priv->kind = leakshield;
+
+		priv->num_fans = 0;
+		priv->num_temp_sensors = LEAKSHIELD_NUM_SENSORS;
+		priv->temp_sensor_start_offset = LEAKSHIELD_TEMPERATURE_1;
+
+		priv->temp_label = label_leakshield_temp_sensors;
+		priv->speed_label = label_leakshield_fan_speed;
+		break;
 	case USB_PRODUCT_ID_AQUASTREAMXT:
 		priv->kind = aquastreamxt;
 
@@ -1707,6 +1807,7 @@  static const struct hid_device_id aqc_table[] = {
 	{ HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_OCTO) },
 	{ HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_QUADRO) },
 	{ HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_HIGHFLOWNEXT) },
+	{ HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_LEAKSHIELD) },
 	{ HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_AQUASTREAMXT) },
 	{ HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_AQUASTREAMULT) },
 	{ HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_POWERADJUST3) },