diff mbox series

[v7,1/3] dt-bindings: iio/temperature: Add thermocouple types (and doc)

Message ID 20190326111842.12399-1-patrick.havelange@essensium.com (mailing list archive)
State New, archived
Headers show
Series [v7,1/3] dt-bindings: iio/temperature: Add thermocouple types (and doc) | expand

Commit Message

Patrick Havelange March 26, 2019, 11:18 a.m. UTC
This patch introduces common thermocouple types used by various
temperature sensors. Also a brief documentation explaining this
"thermocouple-type" property.

Signed-off-by: Patrick Havelange <patrick.havelange@essensium.com>
---
Changes v7
 - Merge header and doc in same patch
 - Doc:add it's a single cell entry
 - Doc:removed non complete example

Changes v6
 - Add this file
---
 .../iio/temperature/temperature-bindings.txt     |  7 +++++++
 .../dt-bindings/iio/temperature/thermocouple.h   | 16 ++++++++++++++++
 2 files changed, 23 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/iio/temperature/temperature-bindings.txt
 create mode 100644 include/dt-bindings/iio/temperature/thermocouple.h

Comments

Jonathan Cameron March 30, 2019, 4:42 p.m. UTC | #1
On Tue, 26 Mar 2019 12:18:40 +0100
Patrick Havelange <patrick.havelange@essensium.com> wrote:

> This patch introduces common thermocouple types used by various
> temperature sensors. Also a brief documentation explaining this
> "thermocouple-type" property.
> 
> Signed-off-by: Patrick Havelange <patrick.havelange@essensium.com>
You have addressed all of Rob's feedback I think, so I'll not pester
Rob for any follow up (always welcome of course if he wants to give it!)

Applied to the togreg branch of iio.git and pushed out as testing for
the autobuilders to play with it.

Thanks,

Jonathan

> ---
> Changes v7
>  - Merge header and doc in same patch
>  - Doc:add it's a single cell entry
>  - Doc:removed non complete example
> 
> Changes v6
>  - Add this file
> ---
>  .../iio/temperature/temperature-bindings.txt     |  7 +++++++
>  .../dt-bindings/iio/temperature/thermocouple.h   | 16 ++++++++++++++++
>  2 files changed, 23 insertions(+)
>  create mode 100644 Documentation/devicetree/bindings/iio/temperature/temperature-bindings.txt
>  create mode 100644 include/dt-bindings/iio/temperature/thermocouple.h
> 
> diff --git a/Documentation/devicetree/bindings/iio/temperature/temperature-bindings.txt b/Documentation/devicetree/bindings/iio/temperature/temperature-bindings.txt
> new file mode 100644
> index 000000000000..8f339cab74ae
> --- /dev/null
> +++ b/Documentation/devicetree/bindings/iio/temperature/temperature-bindings.txt
> @@ -0,0 +1,7 @@
> +If the temperature sensor device can be configured to use some specific
> +thermocouple type, you can use the defined types provided in the file
> +"include/dt-bindings/iio/temperature/thermocouple.h".
> +
> +Property:
> +thermocouple-type:	A single cell representing the type of the thermocouple
> +			used by the device.
> diff --git a/include/dt-bindings/iio/temperature/thermocouple.h b/include/dt-bindings/iio/temperature/thermocouple.h
> new file mode 100644
> index 000000000000..ce037f5238ac
> --- /dev/null
> +++ b/include/dt-bindings/iio/temperature/thermocouple.h
> @@ -0,0 +1,16 @@
> +/* SPDX-License-Identifier: GPL-2.0 */
> +
> +#ifndef _DT_BINDINGS_TEMPERATURE_THERMOCOUPLE_H
> +#define _DT_BINDINGS_TEMPERATURE_THERMOCOUPLE_H
> +
> +
> +#define THERMOCOUPLE_TYPE_B	0x00
> +#define THERMOCOUPLE_TYPE_E	0x01
> +#define THERMOCOUPLE_TYPE_J	0x02
> +#define THERMOCOUPLE_TYPE_K	0x03
> +#define THERMOCOUPLE_TYPE_N	0x04
> +#define THERMOCOUPLE_TYPE_R	0x05
> +#define THERMOCOUPLE_TYPE_S	0x06
> +#define THERMOCOUPLE_TYPE_T	0x07
> +
> +#endif /* _DT_BINDINGS_TEMPERATURE_THERMOCOUPLE_H */
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/iio/temperature/temperature-bindings.txt b/Documentation/devicetree/bindings/iio/temperature/temperature-bindings.txt
new file mode 100644
index 000000000000..8f339cab74ae
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/temperature/temperature-bindings.txt
@@ -0,0 +1,7 @@ 
+If the temperature sensor device can be configured to use some specific
+thermocouple type, you can use the defined types provided in the file
+"include/dt-bindings/iio/temperature/thermocouple.h".
+
+Property:
+thermocouple-type:	A single cell representing the type of the thermocouple
+			used by the device.
diff --git a/include/dt-bindings/iio/temperature/thermocouple.h b/include/dt-bindings/iio/temperature/thermocouple.h
new file mode 100644
index 000000000000..ce037f5238ac
--- /dev/null
+++ b/include/dt-bindings/iio/temperature/thermocouple.h
@@ -0,0 +1,16 @@ 
+/* SPDX-License-Identifier: GPL-2.0 */
+
+#ifndef _DT_BINDINGS_TEMPERATURE_THERMOCOUPLE_H
+#define _DT_BINDINGS_TEMPERATURE_THERMOCOUPLE_H
+
+
+#define THERMOCOUPLE_TYPE_B	0x00
+#define THERMOCOUPLE_TYPE_E	0x01
+#define THERMOCOUPLE_TYPE_J	0x02
+#define THERMOCOUPLE_TYPE_K	0x03
+#define THERMOCOUPLE_TYPE_N	0x04
+#define THERMOCOUPLE_TYPE_R	0x05
+#define THERMOCOUPLE_TYPE_S	0x06
+#define THERMOCOUPLE_TYPE_T	0x07
+
+#endif /* _DT_BINDINGS_TEMPERATURE_THERMOCOUPLE_H */