diff mbox series

[v2,42/46] iio: adc: ti_am335x_adc: Add the scale information

Message ID 20210902215144.507243-43-miquel.raynal@bootlin.com (mailing list archive)
State Not Applicable
Headers show
Series TI AM437X ADC1 | expand

Commit Message

Miquel Raynal Sept. 2, 2021, 9:51 p.m. UTC
Without the scale, the values returned to the user are just a picture of
the input voltage against the full scale range of the ADC. We need to
provide the actual conversion factor to get milli-Volts values.

Signed-off-by: Miquel Raynal <miquel.raynal@bootlin.com>
Acked-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
---
 drivers/iio/adc/ti_am335x_adc.c | 18 ++++++++++++++++++
 1 file changed, 18 insertions(+)
diff mbox series

Patch

diff --git a/drivers/iio/adc/ti_am335x_adc.c b/drivers/iio/adc/ti_am335x_adc.c
index 72b11d7118aa..751ca70442ba 100644
--- a/drivers/iio/adc/ti_am335x_adc.c
+++ b/drivers/iio/adc/ti_am335x_adc.c
@@ -425,6 +425,7 @@  static int tiadc_channel_init(struct device *dev, struct iio_dev *indio_dev,
 		chan->indexed = 1;
 		chan->channel = adc_dev->channel_line[i];
 		chan->info_mask_separate = BIT(IIO_CHAN_INFO_RAW);
+		chan->info_mask_shared_by_type = BIT(IIO_CHAN_INFO_SCALE);
 		chan->datasheet_name = chan_name_ain[chan->channel];
 		chan->scan_index = i;
 		chan->scan_type.sign = 'u';
@@ -449,6 +450,23 @@  static int tiadc_read_raw(struct iio_dev *indio_dev,
 	unsigned long timeout;
 	int ret;
 
+	switch (mask) {
+	case IIO_CHAN_INFO_RAW:
+		break;
+	case IIO_CHAN_INFO_SCALE:
+		switch (chan->type) {
+		case IIO_VOLTAGE:
+			*val = 1800;
+			*val2 = chan->scan_type.realbits;
+			return IIO_VAL_FRACTIONAL_LOG2;
+		default:
+			return -EINVAL;
+		}
+		break;
+	default:
+		return -EINVAL;
+	}
+
 	if (iio_buffer_enabled(indio_dev))
 		return -EBUSY;