David Lechner Oct. 17, 2021, 1:33 a.m. UTC
This documents new counterX/latch_mode* and
counterX/countY/latched_count* attributes.

The counterX/signalY/*_available are moved to the
counterX/countY/*_available section similar to the way we already have
The counterX/*_component_id and The counterX/signalY/*_component_id
grouped together so that we don't have to start a 3rd redundant section
for device-level *_available section.

Signed-off-by: David Lechner <david@lechnology.com>
---
 Documentation/ABI/testing/sysfs-bus-counter | 39 ++++++++++++++++-----
 1 file changed, 30 insertions(+), 9 deletions(-)

Comments

Jonathan Cameron Oct. 17, 2021, 11:26 a.m. UTC | #1
On Sat, 16 Oct 2021 20:33:41 -0500
David Lechner <david@lechnology.com> wrote:

> This documents new counterX/latch_mode* and
> counterX/countY/latched_count* attributes.
> 
> The counterX/signalY/*_available are moved to the
> counterX/countY/*_available section similar to the way we already have
> The counterX/*_component_id and The counterX/signalY/*_component_id
> grouped together so that we don't have to start a 3rd redundant section
> for device-level *_available section.

Two unrelated changes in the same patch. Please redo this as multiple patches.

Thanks,

Jonathan

> 
> Signed-off-by: David Lechner <david@lechnology.com>
> ---
>  Documentation/ABI/testing/sysfs-bus-counter | 39 ++++++++++++++++-----
>  1 file changed, 30 insertions(+), 9 deletions(-)
> 
> diff --git a/Documentation/ABI/testing/sysfs-bus-counter b/Documentation/ABI/testing/sysfs-bus-counter
> index 37d960a8cb1b..78bb1a501007 100644
> --- a/Documentation/ABI/testing/sysfs-bus-counter
> +++ b/Documentation/ABI/testing/sysfs-bus-counter
> @@ -59,10 +59,13 @@ What:		/sys/bus/counter/devices/counterX/countY/error_noise_available
>  What:		/sys/bus/counter/devices/counterX/countY/function_available
>  What:		/sys/bus/counter/devices/counterX/countY/prescaler_available
>  What:		/sys/bus/counter/devices/counterX/countY/signalZ_action_available
> +What:		/sys/bus/counter/devices/counterX/latch_mode_available
> +What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_available
> +What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
>  KernelVersion:	5.2
>  Contact:	linux-iio@vger.kernel.org
>  Description:
> -		Discrete set of available values for the respective Count Y
> +		Discrete set of available values for the respective component
>  		configuration are listed in this file. Values are delimited by
>  		newline characters.
>  
> @@ -147,6 +150,14 @@ Description:
>  			updates	the respective count. Quadrature encoding
>  			determines the direction.
>  
> +What:		/sys/bus/counter/devices/counterX/countY/latched_count
> +KernelVersion:	5.16
> +Contact:	linux-iio@vger.kernel.org
> +Description:
> +		Latched count data of Count Y represented as a string. The value
> +		is latched in based on the trigger selected by the
> +		counterX/latch_mode attribute.
> +
>  What:		/sys/bus/counter/devices/counterX/countY/name
>  KernelVersion:	5.2
>  Contact:	linux-iio@vger.kernel.org
> @@ -209,6 +220,7 @@ What:		/sys/bus/counter/devices/counterX/countY/count_mode_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/direction_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/enable_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/error_noise_component_id
> +What:		/sys/bus/counter/devices/counterX/countY/latched_count_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/prescaler_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/preset_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/preset_enable_component_id
> @@ -218,6 +230,7 @@ What:		/sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
>  What:		/sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
>  What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
>  What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
> +What:		/sys/bus/counter/devices/latch_mode_component_id
>  What:		/sys/bus/counter/devices/unit_timer_enable_component_id
>  What:		/sys/bus/counter/devices/unit_timer_period_component_id
>  What:		/sys/bus/counter/devices/unit_timer_time_component_id
> @@ -244,6 +257,22 @@ Description:
>  		counter_event data structures. The number of elements will be
>  		rounded-up to a power of 2.
>  
> +What:		/sys/bus/counter/devices/counterX/latch_mode
> +KernelVersion:	5.16
> +Contact:	linux-iio@vger.kernel.org
> +Description:
> +		Read/write attribute that selects the trigger for latching
> +		values. Valid values are device-specific (given by
> +		latch_mode_available attribute) and may include:
> +
> +		"Read count":
> +			Reading the countY/count attribute latches values.
> +
> +		"Unit timeout":
> +			Unit timer timeout event latches values.
> +
> +		The latched values can be read from latched_* attributes.
> +
>  What:		/sys/bus/counter/devices/counterX/name
>  KernelVersion:	5.2
>  Contact:	linux-iio@vger.kernel.org
> @@ -298,14 +327,6 @@ Description:
>  		Active level of index input Signal Y; irrelevant in
>  		non-synchronous load mode.
>  
> -What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_available
> -What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
> -KernelVersion:	5.2
> -Contact:	linux-iio@vger.kernel.org
> -Description:
> -		Discrete set of available values for the respective Signal Y
> -		configuration are listed in this file.
> -
>  What:		/sys/bus/counter/devices/counterX/signalY/name
>  KernelVersion:	5.2
>  Contact:	linux-iio@vger.kernel.org
William Breathitt Gray Oct. 27, 2021, 7:54 a.m. UTC | #2
On Sat, Oct 16, 2021 at 08:33:41PM -0500, David Lechner wrote:
> This documents new counterX/latch_mode* and
> counterX/countY/latched_count* attributes.
> 
> The counterX/signalY/*_available are moved to the
> counterX/countY/*_available section similar to the way we already have
> The counterX/*_component_id and The counterX/signalY/*_component_id
> grouped together so that we don't have to start a 3rd redundant section
> for device-level *_available section.
> 
> Signed-off-by: David Lechner <david@lechnology.com>

Please separate these two distinct changes into two distinct patches.

> ---
>  Documentation/ABI/testing/sysfs-bus-counter | 39 ++++++++++++++++-----
>  1 file changed, 30 insertions(+), 9 deletions(-)
> 
> diff --git a/Documentation/ABI/testing/sysfs-bus-counter b/Documentation/ABI/testing/sysfs-bus-counter
> index 37d960a8cb1b..78bb1a501007 100644
> --- a/Documentation/ABI/testing/sysfs-bus-counter
> +++ b/Documentation/ABI/testing/sysfs-bus-counter
> @@ -59,10 +59,13 @@ What:		/sys/bus/counter/devices/counterX/countY/error_noise_available
>  What:		/sys/bus/counter/devices/counterX/countY/function_available
>  What:		/sys/bus/counter/devices/counterX/countY/prescaler_available
>  What:		/sys/bus/counter/devices/counterX/countY/signalZ_action_available
> +What:		/sys/bus/counter/devices/counterX/latch_mode_available
> +What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_available
> +What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
>  KernelVersion:	5.2
>  Contact:	linux-iio@vger.kernel.org
>  Description:
> -		Discrete set of available values for the respective Count Y
> +		Discrete set of available values for the respective component
>  		configuration are listed in this file. Values are delimited by
>  		newline characters.
>  
> @@ -147,6 +150,14 @@ Description:
>  			updates	the respective count. Quadrature encoding
>  			determines the direction.
>  
> +What:		/sys/bus/counter/devices/counterX/countY/latched_count
> +KernelVersion:	5.16
> +Contact:	linux-iio@vger.kernel.org
> +Description:
> +		Latched count data of Count Y represented as a string. The value
> +		is latched in based on the trigger selected by the
> +		counterX/latch_mode attribute.
> +

Latches are pretty common components of devices, and not simply limited
to latching the count data. I wonder if it would be better to omit the
"_count" suffix in order to make this more general. Well, the name
"latched_count" is suitable for counters so you probably don't need to
change it, but it's something to think about in the future.

>  What:		/sys/bus/counter/devices/counterX/countY/name
>  KernelVersion:	5.2
>  Contact:	linux-iio@vger.kernel.org
> @@ -209,6 +220,7 @@ What:		/sys/bus/counter/devices/counterX/countY/count_mode_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/direction_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/enable_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/error_noise_component_id
> +What:		/sys/bus/counter/devices/counterX/countY/latched_count_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/prescaler_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/preset_component_id
>  What:		/sys/bus/counter/devices/counterX/countY/preset_enable_component_id
> @@ -218,6 +230,7 @@ What:		/sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
>  What:		/sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
>  What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
>  What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
> +What:		/sys/bus/counter/devices/latch_mode_component_id
>  What:		/sys/bus/counter/devices/unit_timer_enable_component_id
>  What:		/sys/bus/counter/devices/unit_timer_period_component_id
>  What:		/sys/bus/counter/devices/unit_timer_time_component_id
> @@ -244,6 +257,22 @@ Description:
>  		counter_event data structures. The number of elements will be
>  		rounded-up to a power of 2.
>  
> +What:		/sys/bus/counter/devices/counterX/latch_mode
> +KernelVersion:	5.16
> +Contact:	linux-iio@vger.kernel.org
> +Description:
> +		Read/write attribute that selects the trigger for latching
> +		values. Valid values are device-specific (given by
> +		latch_mode_available attribute) and may include:
> +
> +		"Read count":
> +			Reading the countY/count attribute latches values.
> +
> +		"Unit timeout":
> +			Unit timer timeout event latches values.
> +
> +		The latched values can be read from latched_* attributes.
> +

To make these modes more generic for use in future drivers, I suggest
removing the "Unit " prefix and just leaving that mode as "Timeout". In
a similar vein, rewording "Read count" to "Count read" would make this
mode easier to understand in case a future driver introduces a mode
called "Signal read" or similar.

William Breathitt Gray

>  What:		/sys/bus/counter/devices/counterX/name
>  KernelVersion:	5.2
>  Contact:	linux-iio@vger.kernel.org
> @@ -298,14 +327,6 @@ Description:
>  		Active level of index input Signal Y; irrelevant in
>  		non-synchronous load mode.
>  
> -What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_available
> -What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
> -KernelVersion:	5.2
> -Contact:	linux-iio@vger.kernel.org
> -Description:
> -		Discrete set of available values for the respective Signal Y
> -		configuration are listed in this file.
> -
>  What:		/sys/bus/counter/devices/counterX/signalY/name
>  KernelVersion:	5.2
>  Contact:	linux-iio@vger.kernel.org
> -- 
> 2.25.1
>
David Lechner Oct. 27, 2021, 5 p.m. UTC | #3
On 10/27/21 2:54 AM, William Breathitt Gray wrote:
> On Sat, Oct 16, 2021 at 08:33:41PM -0500, David Lechner wrote:
>> This documents new counterX/latch_mode* and
>> counterX/countY/latched_count* attributes.
>>
>> The counterX/signalY/*_available are moved to the
>> counterX/countY/*_available section similar to the way we already have
>> The counterX/*_component_id and The counterX/signalY/*_component_id
>> grouped together so that we don't have to start a 3rd redundant section
>> for device-level *_available section.
>>



>> @@ -147,6 +150,14 @@ Description:
>>   			updates	the respective count. Quadrature encoding
>>   			determines the direction.
>>   
>> +What:		/sys/bus/counter/devices/counterX/countY/latched_count
>> +KernelVersion:	5.16
>> +Contact:	linux-iio@vger.kernel.org
>> +Description:
>> +		Latched count data of Count Y represented as a string. The value
>> +		is latched in based on the trigger selected by the
>> +		counterX/latch_mode attribute.
>> +
> 
> Latches are pretty common components of devices, and not simply limited
> to latching the count data. I wonder if it would be better to omit the
> "_count" suffix in order to make this more general. Well, the name
> "latched_count" is suitable for counters so you probably don't need to
> change it, but it's something to think about in the future.
> 

I chose the name counterX/countY/latched_count since we already have
counterX/countY/count to read the same (not latched) count. This
indicates that they are the same quantity, just from a different
point in time.

Also for consideration, this particular hardware actually has 3
independent latched counts. One is triggered by the selected
latched_mode. One is triggered by the index signal and one is
triggered by the strobe signal.

The latter two are not implemented in this series, but if there were a
use for those, I would probably submit attributes index_latched_count
and strobe_latched_count. These are unaffected by the latch_mode.

Similarly, the unit timer has a timer latch and a period latch. If we
change the unit timer to be a Count as suggested, then the latched
timer would basically be the same as latched_count. Both of these
are triggered by the selected latch_mode.

So, I supposed if we wanted to keep things really generic, we would
want to introduce some sort of "latch trigger" component (synapse?).
There could theoretically be multiple configurable triggers, so
the proposed latch_mode might need to be made indexed or part of
an index component/extension.



>>   What:		/sys/bus/counter/devices/counterX/countY/name
>>   KernelVersion:	5.2
>>   Contact:	linux-iio@vger.kernel.org
>> @@ -209,6 +220,7 @@ What:		/sys/bus/counter/devices/counterX/countY/count_mode_component_id
>>   What:		/sys/bus/counter/devices/counterX/countY/direction_component_id
>>   What:		/sys/bus/counter/devices/counterX/countY/enable_component_id
>>   What:		/sys/bus/counter/devices/counterX/countY/error_noise_component_id
>> +What:		/sys/bus/counter/devices/counterX/countY/latched_count_component_id
>>   What:		/sys/bus/counter/devices/counterX/countY/prescaler_component_id
>>   What:		/sys/bus/counter/devices/counterX/countY/preset_component_id
>>   What:		/sys/bus/counter/devices/counterX/countY/preset_enable_component_id
>> @@ -218,6 +230,7 @@ What:		/sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
>>   What:		/sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
>>   What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
>>   What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
>> +What:		/sys/bus/counter/devices/latch_mode_component_id
>>   What:		/sys/bus/counter/devices/unit_timer_enable_component_id
>>   What:		/sys/bus/counter/devices/unit_timer_period_component_id
>>   What:		/sys/bus/counter/devices/unit_timer_time_component_id

Just noticing here, I missed the counterX in the device-level components.

>> @@ -244,6 +257,22 @@ Description:
>>   		counter_event data structures. The number of elements will be
>>   		rounded-up to a power of 2.
>>   
>> +What:		/sys/bus/counter/devices/counterX/latch_mode
>> +KernelVersion:	5.16
>> +Contact:	linux-iio@vger.kernel.org
>> +Description:
>> +		Read/write attribute that selects the trigger for latching
>> +		values. Valid values are device-specific (given by
>> +		latch_mode_available attribute) and may include:
>> +
>> +		"Read count":
>> +			Reading the countY/count attribute latches values.
>> +
>> +		"Unit timeout":
>> +			Unit timer timeout event latches values.
>> +
>> +		The latched values can be read from latched_* attributes.
>> +
> 
> To make these modes more generic for use in future drivers, I suggest
> removing the "Unit " prefix and just leaving that mode as "Timeout". In
> a similar vein, rewording "Read count" to "Count read" would make this
> mode easier to understand in case a future driver introduces a mode
> called "Signal read" or similar.
> 

Continuing my thoughts from above and taking this suggestion into
consideration...

Maybe we need a /sys/bus/counter/devices/counterX/latchY component.
This would represent the trigger for a latch. For the TI eQEP in this
series, there are potentially 3 of these (only one implemented for
now).

latchY would have a required `trigger` attribute that would describe
what triggers the latch. If the trigger is selectable, there would be
a `triggers_available` attribute that would list the possible triggers,
otherwise the `trigger` attribute would just be read-only. Available
triggers could could be "X read" where X is a fully qualified component
name, e.g. "Count0 count read" or a fully qualified event, e.g.
"Count1 overflow event" (this is unit timer timeout in generic counter
terms). But, there may be potential triggers that don't fit either
of these patterns.

Although not currently needed, the triggers for the index and strobe
latches on the eQEP get more interesting. The `triggers_available` for
the index latch are "index rising edge", "index falling edge" and
"software" (this would require a `software_trigger` attribute that
would be written to trigger the latch). The `triggers_available` for
the strobe latch are "strobe rising edge" and "strobe rising edge if
direction is clockwise and strobe falling edge if direction is
counterclockwise".

Circling back to the beginning, to read latched registers, there
would be attributes like counterX/countY/latchY_count instead of
the proposed counterX/countY/latched_count. So for the eQEP there
would be counter0/count0/latch0_count (triggered by reading
counter0/count0/count or counter0/count1 overflow event),
counter0/count0/latch1_count (triggered by index signal),
counter0/count0/latch2_count (triggered by strobe signal),
counter0/count1/latch0_count (unit timer latched timer trigger
by same trigger as counter0/count0/latch0_count) and
counter0/count0/latch0_ceiling (unit timer latched period
triggered by same trigger as counter0/count0/latch0_count).
William Breathitt Gray Oct. 30, 2021, 1:32 a.m. UTC | #4
On Wed, Oct 27, 2021 at 12:00:24PM -0500, David Lechner wrote:
> On 10/27/21 2:54 AM, William Breathitt Gray wrote:
> > On Sat, Oct 16, 2021 at 08:33:41PM -0500, David Lechner wrote:
> >> @@ -147,6 +150,14 @@ Description:
> >>   			updates	the respective count. Quadrature encoding
> >>   			determines the direction.
> >>   
> >> +What:		/sys/bus/counter/devices/counterX/countY/latched_count
> >> +KernelVersion:	5.16
> >> +Contact:	linux-iio@vger.kernel.org
> >> +Description:
> >> +		Latched count data of Count Y represented as a string. The value
> >> +		is latched in based on the trigger selected by the
> >> +		counterX/latch_mode attribute.
> >> +
> > 
> > Latches are pretty common components of devices, and not simply limited
> > to latching the count data. I wonder if it would be better to omit the
> > "_count" suffix in order to make this more general. Well, the name
> > "latched_count" is suitable for counters so you probably don't need to
> > change it, but it's something to think about in the future.
> > 
> 
> I chose the name counterX/countY/latched_count since we already have
> counterX/countY/count to read the same (not latched) count. This
> indicates that they are the same quantity, just from a different
> point in time.
> 
> Also for consideration, this particular hardware actually has 3
> independent latched counts. One is triggered by the selected
> latched_mode. One is triggered by the index signal and one is
> triggered by the strobe signal.
> 
> The latter two are not implemented in this series, but if there were a
> use for those, I would probably submit attributes index_latched_count
> and strobe_latched_count. These are unaffected by the latch_mode.
> 
> Similarly, the unit timer has a timer latch and a period latch. If we
> change the unit timer to be a Count as suggested, then the latched
> timer would basically be the same as latched_count. Both of these
> are triggered by the selected latch_mode.
> 
> So, I supposed if we wanted to keep things really generic, we would
> want to introduce some sort of "latch trigger" component (synapse?).
> There could theoretically be multiple configurable triggers, so
> the proposed latch_mode might need to be made indexed or part of
> an index component/extension.

Aside from deriving their latched values from the current and historical
count values, these latches don't seem to be related to Counters in an
operational sense; i.e. they don't really fit into the Counter subsystem
paradigm because they aren't functionally counters, but rather just use
the count values here as source data for their own operations. As such,
I'm not sure yet if they really belong in the Counter subsystem or
somewhere else in the IIO subsystem.

> 
> >>   What:		/sys/bus/counter/devices/counterX/countY/name
> >>   KernelVersion:	5.2
> >>   Contact:	linux-iio@vger.kernel.org
> >> @@ -209,6 +220,7 @@ What:		/sys/bus/counter/devices/counterX/countY/count_mode_component_id
> >>   What:		/sys/bus/counter/devices/counterX/countY/direction_component_id
> >>   What:		/sys/bus/counter/devices/counterX/countY/enable_component_id
> >>   What:		/sys/bus/counter/devices/counterX/countY/error_noise_component_id
> >> +What:		/sys/bus/counter/devices/counterX/countY/latched_count_component_id
> >>   What:		/sys/bus/counter/devices/counterX/countY/prescaler_component_id
> >>   What:		/sys/bus/counter/devices/counterX/countY/preset_component_id
> >>   What:		/sys/bus/counter/devices/counterX/countY/preset_enable_component_id
> >> @@ -218,6 +230,7 @@ What:		/sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
> >>   What:		/sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
> >>   What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
> >>   What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
> >> +What:		/sys/bus/counter/devices/latch_mode_component_id
> >>   What:		/sys/bus/counter/devices/unit_timer_enable_component_id
> >>   What:		/sys/bus/counter/devices/unit_timer_period_component_id
> >>   What:		/sys/bus/counter/devices/unit_timer_time_component_id
> 
> Just noticing here, I missed the counterX in the device-level components.
> 
> >> @@ -244,6 +257,22 @@ Description:
> >>   		counter_event data structures. The number of elements will be
> >>   		rounded-up to a power of 2.
> >>   
> >> +What:		/sys/bus/counter/devices/counterX/latch_mode
> >> +KernelVersion:	5.16
> >> +Contact:	linux-iio@vger.kernel.org
> >> +Description:
> >> +		Read/write attribute that selects the trigger for latching
> >> +		values. Valid values are device-specific (given by
> >> +		latch_mode_available attribute) and may include:
> >> +
> >> +		"Read count":
> >> +			Reading the countY/count attribute latches values.
> >> +
> >> +		"Unit timeout":
> >> +			Unit timer timeout event latches values.
> >> +
> >> +		The latched values can be read from latched_* attributes.
> >> +
> > 
> > To make these modes more generic for use in future drivers, I suggest
> > removing the "Unit " prefix and just leaving that mode as "Timeout". In
> > a similar vein, rewording "Read count" to "Count read" would make this
> > mode easier to understand in case a future driver introduces a mode
> > called "Signal read" or similar.
> > 
> 
> Continuing my thoughts from above and taking this suggestion into
> consideration...
> 
> Maybe we need a /sys/bus/counter/devices/counterX/latchY component.
> This would represent the trigger for a latch. For the TI eQEP in this
> series, there are potentially 3 of these (only one implemented for
> now).
> 
> latchY would have a required `trigger` attribute that would describe
> what triggers the latch. If the trigger is selectable, there would be
> a `triggers_available` attribute that would list the possible triggers,
> otherwise the `trigger` attribute would just be read-only. Available
> triggers could could be "X read" where X is a fully qualified component
> name, e.g. "Count0 count read" or a fully qualified event, e.g.
> "Count1 overflow event" (this is unit timer timeout in generic counter
> terms). But, there may be potential triggers that don't fit either
> of these patterns.
> 
> Although not currently needed, the triggers for the index and strobe
> latches on the eQEP get more interesting. The `triggers_available` for
> the index latch are "index rising edge", "index falling edge" and
> "software" (this would require a `software_trigger` attribute that
> would be written to trigger the latch). The `triggers_available` for
> the strobe latch are "strobe rising edge" and "strobe rising edge if
> direction is clockwise and strobe falling edge if direction is
> counterclockwise".
> 
> Circling back to the beginning, to read latched registers, there
> would be attributes like counterX/countY/latchY_count instead of
> the proposed counterX/countY/latched_count. So for the eQEP there
> would be counter0/count0/latch0_count (triggered by reading
> counter0/count0/count or counter0/count1 overflow event),
> counter0/count0/latch1_count (triggered by index signal),
> counter0/count0/latch2_count (triggered by strobe signal),
> counter0/count1/latch0_count (unit timer latched timer trigger
> by same trigger as counter0/count0/latch0_count) and
> counter0/count0/latch0_ceiling (unit timer latched period
> triggered by same trigger as counter0/count0/latch0_count).

The complexity of configuration here is a good indication that these
latches deserve their own tree structure as you suggest. Furthermore, we
see that there at least three of these latches available for this
particular device, so just a single "latch_count" or similar will not be
sufficient -- enumeration of the form /sys/bus/../latchY or similar
would be prudent.

Jonathan, perhaps you have some insight here. From a functional aspect,
latches are not unique to counter devices, so I wonder if the IIO
subsytem has already encountered similar functionality amongst its
drivers. Essentially, a latch is just a memory buffer provided by the
device.

For the TI eQEP device here, the buffer for each latch provides a single
read-only value that is updated by the device; the update behavior can
be configured by respective control registers. However, it's not so
far-fetched to assume that there a other devices out that that have
buffers spanning multiple latched values storing historical data.

Because a latch can theoretically provide any sort of data, not
necessary count values, it seems reasonable that supporting latches
would involve their own interface independent of the Counter paradigm.
How that interface looks is the question. Should the TI eQEP latches
here be exposed through some sort of generic latches interface, or
would it be better to have a more abstract representation of what these
latches are for; e.g. if these latches are used to measure speed, then
some sort of IIO speedometer interface might be appropriate).

William Breathitt Gray
Jonathan Cameron Oct. 30, 2021, 2:39 p.m. UTC | #5
On Sat, 30 Oct 2021 10:32:57 +0900
William Breathitt Gray <vilhelm.gray@gmail.com> wrote:

> On Wed, Oct 27, 2021 at 12:00:24PM -0500, David Lechner wrote:
> > On 10/27/21 2:54 AM, William Breathitt Gray wrote:  
> > > On Sat, Oct 16, 2021 at 08:33:41PM -0500, David Lechner wrote:  
> > >> @@ -147,6 +150,14 @@ Description:
> > >>   			updates	the respective count. Quadrature encoding
> > >>   			determines the direction.
> > >>   
> > >> +What:		/sys/bus/counter/devices/counterX/countY/latched_count
> > >> +KernelVersion:	5.16
> > >> +Contact:	linux-iio@vger.kernel.org
> > >> +Description:
> > >> +		Latched count data of Count Y represented as a string. The value
> > >> +		is latched in based on the trigger selected by the
> > >> +		counterX/latch_mode attribute.
> > >> +  
> > > 
> > > Latches are pretty common components of devices, and not simply limited
> > > to latching the count data. I wonder if it would be better to omit the
> > > "_count" suffix in order to make this more general. Well, the name
> > > "latched_count" is suitable for counters so you probably don't need to
> > > change it, but it's something to think about in the future.
> > >   
> > 
> > I chose the name counterX/countY/latched_count since we already have
> > counterX/countY/count to read the same (not latched) count. This
> > indicates that they are the same quantity, just from a different
> > point in time.
> > 
> > Also for consideration, this particular hardware actually has 3
> > independent latched counts. One is triggered by the selected
> > latched_mode. One is triggered by the index signal and one is
> > triggered by the strobe signal.
> > 
> > The latter two are not implemented in this series, but if there were a
> > use for those, I would probably submit attributes index_latched_count
> > and strobe_latched_count. These are unaffected by the latch_mode.
> > 
> > Similarly, the unit timer has a timer latch and a period latch. If we
> > change the unit timer to be a Count as suggested, then the latched
> > timer would basically be the same as latched_count. Both of these
> > are triggered by the selected latch_mode.
> > 
> > So, I supposed if we wanted to keep things really generic, we would
> > want to introduce some sort of "latch trigger" component (synapse?).
> > There could theoretically be multiple configurable triggers, so
> > the proposed latch_mode might need to be made indexed or part of
> > an index component/extension.  
> 
> Aside from deriving their latched values from the current and historical
> count values, these latches don't seem to be related to Counters in an
> operational sense; i.e. they don't really fit into the Counter subsystem
> paradigm because they aren't functionally counters, but rather just use
> the count values here as source data for their own operations. As such,
> I'm not sure yet if they really belong in the Counter subsystem or
> somewhere else in the IIO subsystem.

In this particular case I think we are talking about latching counts rather
than something else?  So one event happens and we latch the count at that
point.

The IIO equivalent is a trigger event driving data into a buffer.
There are a few examples of this though it's pretty rare.
The most general corner case is probably what we see with impact sensors.
In those cases we have data captured around an event (rather than a single
latched value).

They are rather complex beasts but the best we've managed is a special
trigger used only with that device and some control attributes to say what
is captured when the trigger fires.  Note this is a stetch in IIO because
normally triggers are one per sample...

> 
> >   
> > >>   What:		/sys/bus/counter/devices/counterX/countY/name
> > >>   KernelVersion:	5.2
> > >>   Contact:	linux-iio@vger.kernel.org
> > >> @@ -209,6 +220,7 @@ What:		/sys/bus/counter/devices/counterX/countY/count_mode_component_id
> > >>   What:		/sys/bus/counter/devices/counterX/countY/direction_component_id
> > >>   What:		/sys/bus/counter/devices/counterX/countY/enable_component_id
> > >>   What:		/sys/bus/counter/devices/counterX/countY/error_noise_component_id
> > >> +What:		/sys/bus/counter/devices/counterX/countY/latched_count_component_id
> > >>   What:		/sys/bus/counter/devices/counterX/countY/prescaler_component_id
> > >>   What:		/sys/bus/counter/devices/counterX/countY/preset_component_id
> > >>   What:		/sys/bus/counter/devices/counterX/countY/preset_enable_component_id
> > >> @@ -218,6 +230,7 @@ What:		/sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
> > >>   What:		/sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
> > >>   What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
> > >>   What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
> > >> +What:		/sys/bus/counter/devices/latch_mode_component_id
> > >>   What:		/sys/bus/counter/devices/unit_timer_enable_component_id
> > >>   What:		/sys/bus/counter/devices/unit_timer_period_component_id
> > >>   What:		/sys/bus/counter/devices/unit_timer_time_component_id  
> > 
> > Just noticing here, I missed the counterX in the device-level components.
> >   
> > >> @@ -244,6 +257,22 @@ Description:
> > >>   		counter_event data structures. The number of elements will be
> > >>   		rounded-up to a power of 2.
> > >>   
> > >> +What:		/sys/bus/counter/devices/counterX/latch_mode
> > >> +KernelVersion:	5.16
> > >> +Contact:	linux-iio@vger.kernel.org
> > >> +Description:
> > >> +		Read/write attribute that selects the trigger for latching
> > >> +		values. Valid values are device-specific (given by
> > >> +		latch_mode_available attribute) and may include:
> > >> +
> > >> +		"Read count":
> > >> +			Reading the countY/count attribute latches values.
> > >> +
> > >> +		"Unit timeout":
> > >> +			Unit timer timeout event latches values.
> > >> +
> > >> +		The latched values can be read from latched_* attributes.
> > >> +  
> > > 
> > > To make these modes more generic for use in future drivers, I suggest
> > > removing the "Unit " prefix and just leaving that mode as "Timeout". In
> > > a similar vein, rewording "Read count" to "Count read" would make this
> > > mode easier to understand in case a future driver introduces a mode
> > > called "Signal read" or similar.
> > >   
> > 
> > Continuing my thoughts from above and taking this suggestion into
> > consideration...
> > 
> > Maybe we need a /sys/bus/counter/devices/counterX/latchY component.
> > This would represent the trigger for a latch. For the TI eQEP in this
> > series, there are potentially 3 of these (only one implemented for
> > now).
> > 
> > latchY would have a required `trigger` attribute that would describe
> > what triggers the latch. If the trigger is selectable, there would be
> > a `triggers_available` attribute that would list the possible triggers,
> > otherwise the `trigger` attribute would just be read-only. Available
> > triggers could could be "X read" where X is a fully qualified component
> > name, e.g. "Count0 count read" or a fully qualified event, e.g.
> > "Count1 overflow event" (this is unit timer timeout in generic counter
> > terms). But, there may be potential triggers that don't fit either
> > of these patterns.
> > 
> > Although not currently needed, the triggers for the index and strobe
> > latches on the eQEP get more interesting. The `triggers_available` for
> > the index latch are "index rising edge", "index falling edge" and
> > "software" (this would require a `software_trigger` attribute that
> > would be written to trigger the latch). The `triggers_available` for
> > the strobe latch are "strobe rising edge" and "strobe rising edge if
> > direction is clockwise and strobe falling edge if direction is
> > counterclockwise".
> > 
> > Circling back to the beginning, to read latched registers, there
> > would be attributes like counterX/countY/latchY_count instead of
> > the proposed counterX/countY/latched_count. So for the eQEP there
> > would be counter0/count0/latch0_count (triggered by reading
> > counter0/count0/count or counter0/count1 overflow event),
> > counter0/count0/latch1_count (triggered by index signal),
> > counter0/count0/latch2_count (triggered by strobe signal),
> > counter0/count1/latch0_count (unit timer latched timer trigger
> > by same trigger as counter0/count0/latch0_count) and
> > counter0/count0/latch0_ceiling (unit timer latched period
> > triggered by same trigger as counter0/count0/latch0_count).  
> 
> The complexity of configuration here is a good indication that these
> latches deserve their own tree structure as you suggest. Furthermore, we
> see that there at least three of these latches available for this
> particular device, so just a single "latch_count" or similar will not be
> sufficient -- enumeration of the form /sys/bus/../latchY or similar
> would be prudent.
> 
> Jonathan, perhaps you have some insight here. From a functional aspect,
> latches are not unique to counter devices, so I wonder if the IIO
> subsytem has already encountered similar functionality amongst its
> drivers. Essentially, a latch is just a memory buffer provided by the
> device.

As mentioned above, they exist but are fairly rare, unless you think
of time triggers as being in this category in which case any data
ready signal is basically like this.  Ignoring that common case,
we map them onto a device specific trigger (one that has a
validate_device callback to check it's being assigned to that right device).
Another case where we do odd things like this is SoC ADCs that support touch
screen type functionality.  In those case we are grabbing data only when
the screen is touched.


> 
> For the TI eQEP device here, the buffer for each latch provides a single
> read-only value that is updated by the device; the update behavior can
> be configured by respective control registers. However, it's not so
> far-fetched to assume that there a other devices out that that have
> buffers spanning multiple latched values storing historical data.

A fifo filled on 'index' event or similar would indeed be a reasonable
bit of hardware to build.  I've world with PLC code that does this sort
of things so the requirements are there (tracking products on a conveyor
belt would be a classic case - you latch the count when a light gate is
broken).

> 
> Because a latch can theoretically provide any sort of data, not
> necessary count values, it seems reasonable that supporting latches
> would involve their own interface independent of the Counter paradigm.
> How that interface looks is the question. Should the TI eQEP latches
> here be exposed through some sort of generic latches interface, or
> would it be better to have a more abstract representation of what these
> latches are for; e.g. if these latches are used to measure speed, then
> some sort of IIO speedometer interface might be appropriate).

I'd suggest trying to avoid being too generic about this.  There might
be some reason to do it in the future but trying to define interfaces
across subsystems is a pain.  More likely we'll get some bridging
type drivers to map between different abstractions if they are needed.

Jonathan

> 
> William Breathitt Gray
William Breathitt Gray Nov. 1, 2021, 5:11 a.m. UTC | #6
On Sat, Oct 30, 2021 at 03:39:39PM +0100, Jonathan Cameron wrote:
> On Sat, 30 Oct 2021 10:32:57 +0900
> William Breathitt Gray <vilhelm.gray@gmail.com> wrote:
> 
> > On Wed, Oct 27, 2021 at 12:00:24PM -0500, David Lechner wrote:
> > > On 10/27/21 2:54 AM, William Breathitt Gray wrote:  
> > > > On Sat, Oct 16, 2021 at 08:33:41PM -0500, David Lechner wrote:  
> > > >> @@ -147,6 +150,14 @@ Description:
> > > >>   			updates	the respective count. Quadrature encoding
> > > >>   			determines the direction.
> > > >>   
> > > >> +What:		/sys/bus/counter/devices/counterX/countY/latched_count
> > > >> +KernelVersion:	5.16
> > > >> +Contact:	linux-iio@vger.kernel.org
> > > >> +Description:
> > > >> +		Latched count data of Count Y represented as a string. The value
> > > >> +		is latched in based on the trigger selected by the
> > > >> +		counterX/latch_mode attribute.
> > > >> +  
> > > > 
> > > > Latches are pretty common components of devices, and not simply limited
> > > > to latching the count data. I wonder if it would be better to omit the
> > > > "_count" suffix in order to make this more general. Well, the name
> > > > "latched_count" is suitable for counters so you probably don't need to
> > > > change it, but it's something to think about in the future.
> > > >   
> > > 
> > > I chose the name counterX/countY/latched_count since we already have
> > > counterX/countY/count to read the same (not latched) count. This
> > > indicates that they are the same quantity, just from a different
> > > point in time.
> > > 
> > > Also for consideration, this particular hardware actually has 3
> > > independent latched counts. One is triggered by the selected
> > > latched_mode. One is triggered by the index signal and one is
> > > triggered by the strobe signal.
> > > 
> > > The latter two are not implemented in this series, but if there were a
> > > use for those, I would probably submit attributes index_latched_count
> > > and strobe_latched_count. These are unaffected by the latch_mode.
> > > 
> > > Similarly, the unit timer has a timer latch and a period latch. If we
> > > change the unit timer to be a Count as suggested, then the latched
> > > timer would basically be the same as latched_count. Both of these
> > > are triggered by the selected latch_mode.
> > > 
> > > So, I supposed if we wanted to keep things really generic, we would
> > > want to introduce some sort of "latch trigger" component (synapse?).
> > > There could theoretically be multiple configurable triggers, so
> > > the proposed latch_mode might need to be made indexed or part of
> > > an index component/extension.  
> > 
> > Aside from deriving their latched values from the current and historical
> > count values, these latches don't seem to be related to Counters in an
> > operational sense; i.e. they don't really fit into the Counter subsystem
> > paradigm because they aren't functionally counters, but rather just use
> > the count values here as source data for their own operations. As such,
> > I'm not sure yet if they really belong in the Counter subsystem or
> > somewhere else in the IIO subsystem.
> 
> In this particular case I think we are talking about latching counts rather
> than something else?  So one event happens and we latch the count at that
> point.

It looks like the unit timer has latches for its time and period values
as well IIUC, but at this patch only implements support for the count
latch. I think if we were to implement support for these other latches,
we would probably expose them in a similar way and just call them
respectively latched_count, latched_period, etc.

> The IIO equivalent is a trigger event driving data into a buffer.
> There are a few examples of this though it's pretty rare.
> The most general corner case is probably what we see with impact sensors.
> In those cases we have data captured around an event (rather than a single
> latched value).
> 
> They are rather complex beasts but the best we've managed is a special
> trigger used only with that device and some control attributes to say what
> is captured when the trigger fires.  Note this is a stetch in IIO because
> normally triggers are one per sample...

Yes, complexity is something I would like to avoid. I don't want to
shoehorn functionality into the Counter subsystem if a simpler approach
is possible. However, it may be good news to hear that these kind of
complex devices are rarer, so a simple approach with the TI eQEP might
be the best option.

> > 
> > >   
> > > >>   What:		/sys/bus/counter/devices/counterX/countY/name
> > > >>   KernelVersion:	5.2
> > > >>   Contact:	linux-iio@vger.kernel.org
> > > >> @@ -209,6 +220,7 @@ What:		/sys/bus/counter/devices/counterX/countY/count_mode_component_id
> > > >>   What:		/sys/bus/counter/devices/counterX/countY/direction_component_id
> > > >>   What:		/sys/bus/counter/devices/counterX/countY/enable_component_id
> > > >>   What:		/sys/bus/counter/devices/counterX/countY/error_noise_component_id
> > > >> +What:		/sys/bus/counter/devices/counterX/countY/latched_count_component_id
> > > >>   What:		/sys/bus/counter/devices/counterX/countY/prescaler_component_id
> > > >>   What:		/sys/bus/counter/devices/counterX/countY/preset_component_id
> > > >>   What:		/sys/bus/counter/devices/counterX/countY/preset_enable_component_id
> > > >> @@ -218,6 +230,7 @@ What:		/sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
> > > >>   What:		/sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
> > > >>   What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
> > > >>   What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
> > > >> +What:		/sys/bus/counter/devices/latch_mode_component_id
> > > >>   What:		/sys/bus/counter/devices/unit_timer_enable_component_id
> > > >>   What:		/sys/bus/counter/devices/unit_timer_period_component_id
> > > >>   What:		/sys/bus/counter/devices/unit_timer_time_component_id  
> > > 
> > > Just noticing here, I missed the counterX in the device-level components.
> > >   
> > > >> @@ -244,6 +257,22 @@ Description:
> > > >>   		counter_event data structures. The number of elements will be
> > > >>   		rounded-up to a power of 2.
> > > >>   
> > > >> +What:		/sys/bus/counter/devices/counterX/latch_mode
> > > >> +KernelVersion:	5.16
> > > >> +Contact:	linux-iio@vger.kernel.org
> > > >> +Description:
> > > >> +		Read/write attribute that selects the trigger for latching
> > > >> +		values. Valid values are device-specific (given by
> > > >> +		latch_mode_available attribute) and may include:

By the way, the latch_mode_available comment here can be removed as it's
already obvious the respective *_available sysfs attribute is where the
possible values are given.

> > > >> +
> > > >> +		"Read count":
> > > >> +			Reading the countY/count attribute latches values.
> > > >> +
> > > >> +		"Unit timeout":
> > > >> +			Unit timer timeout event latches values.
> > > >> +
> > > >> +		The latched values can be read from latched_* attributes.
> > > >> +  
> > > > 
> > > > To make these modes more generic for use in future drivers, I suggest
> > > > removing the "Unit " prefix and just leaving that mode as "Timeout". In
> > > > a similar vein, rewording "Read count" to "Count read" would make this
> > > > mode easier to understand in case a future driver introduces a mode
> > > > called "Signal read" or similar.
> > > >   
> > > 
> > > Continuing my thoughts from above and taking this suggestion into
> > > consideration...
> > > 
> > > Maybe we need a /sys/bus/counter/devices/counterX/latchY component.
> > > This would represent the trigger for a latch. For the TI eQEP in this
> > > series, there are potentially 3 of these (only one implemented for
> > > now).
> > > 
> > > latchY would have a required `trigger` attribute that would describe
> > > what triggers the latch. If the trigger is selectable, there would be
> > > a `triggers_available` attribute that would list the possible triggers,
> > > otherwise the `trigger` attribute would just be read-only. Available
> > > triggers could could be "X read" where X is a fully qualified component
> > > name, e.g. "Count0 count read" or a fully qualified event, e.g.
> > > "Count1 overflow event" (this is unit timer timeout in generic counter
> > > terms). But, there may be potential triggers that don't fit either
> > > of these patterns.
> > > 
> > > Although not currently needed, the triggers for the index and strobe
> > > latches on the eQEP get more interesting. The `triggers_available` for
> > > the index latch are "index rising edge", "index falling edge" and
> > > "software" (this would require a `software_trigger` attribute that
> > > would be written to trigger the latch). The `triggers_available` for
> > > the strobe latch are "strobe rising edge" and "strobe rising edge if
> > > direction is clockwise and strobe falling edge if direction is
> > > counterclockwise".
> > > 
> > > Circling back to the beginning, to read latched registers, there
> > > would be attributes like counterX/countY/latchY_count instead of
> > > the proposed counterX/countY/latched_count. So for the eQEP there
> > > would be counter0/count0/latch0_count (triggered by reading
> > > counter0/count0/count or counter0/count1 overflow event),
> > > counter0/count0/latch1_count (triggered by index signal),
> > > counter0/count0/latch2_count (triggered by strobe signal),
> > > counter0/count1/latch0_count (unit timer latched timer trigger
> > > by same trigger as counter0/count0/latch0_count) and
> > > counter0/count0/latch0_ceiling (unit timer latched period
> > > triggered by same trigger as counter0/count0/latch0_count).  
> > 
> > The complexity of configuration here is a good indication that these
> > latches deserve their own tree structure as you suggest. Furthermore, we
> > see that there at least three of these latches available for this
> > particular device, so just a single "latch_count" or similar will not be
> > sufficient -- enumeration of the form /sys/bus/../latchY or similar
> > would be prudent.
> > 
> > Jonathan, perhaps you have some insight here. From a functional aspect,
> > latches are not unique to counter devices, so I wonder if the IIO
> > subsytem has already encountered similar functionality amongst its
> > drivers. Essentially, a latch is just a memory buffer provided by the
> > device.
> 
> As mentioned above, they exist but are fairly rare, unless you think
> of time triggers as being in this category in which case any data
> ready signal is basically like this.  Ignoring that common case,
> we map them onto a device specific trigger (one that has a
> validate_device callback to check it's being assigned to that right device).
> Another case where we do odd things like this is SoC ADCs that support touch
> screen type functionality.  In those case we are grabbing data only when
> the screen is touched.
> 
> 
> > 
> > For the TI eQEP device here, the buffer for each latch provides a single
> > read-only value that is updated by the device; the update behavior can
> > be configured by respective control registers. However, it's not so
> > far-fetched to assume that there a other devices out that that have
> > buffers spanning multiple latched values storing historical data.
> 
> A fifo filled on 'index' event or similar would indeed be a reasonable
> bit of hardware to build.  I've world with PLC code that does this sort
> of things so the requirements are there (tracking products on a conveyor
> belt would be a classic case - you latch the count when a light gate is
> broken).

I've constructed similar devices where I push the current count to a
fifo to track a part's relative position to others on a conveyor belt.
It's possible some quadrature encoding device out has a similar
functionality, but I don't want to jump the gun and start developing an
interface for this if those kinds of device are so rare as to not be
worth the effort.

> > Because a latch can theoretically provide any sort of data, not
> > necessary count values, it seems reasonable that supporting latches
> > would involve their own interface independent of the Counter paradigm.
> > How that interface looks is the question. Should the TI eQEP latches
> > here be exposed through some sort of generic latches interface, or
> > would it be better to have a more abstract representation of what these
> > latches are for; e.g. if these latches are used to measure speed, then
> > some sort of IIO speedometer interface might be appropriate).
> 
> I'd suggest trying to avoid being too generic about this.  There might
> be some reason to do it in the future but trying to define interfaces
> across subsystems is a pain.  More likely we'll get some bridging
> type drivers to map between different abstractions if they are needed.
> 
> Jonathan

I agree, after considering this some more I think it's best to keep this
specific to the use case of the TI eQEP for now. If something more
complex appears in the future then we can address the possibility of a
deadicated interface, but for the time being I think simple extensions
to the Counter subsystem will suffice.

Instead of treating each latch with its own enumerated tree structure,
let's go with the simple approach taken initially here:

	* counterX/countY/latched_count
	* counterX/latch_mode

If desired, a latched_time can be implemented as well; the edge capture
attributes can be exposed in a similar fashion (e.g. latched_period).

Whether latch_mode belongs as a device extension or Count extension is
something I'm still contemplating. If we expose the unit timer under its
own counterX/countY, then latch_mode should be a device extension
because latched_time would simply become latched_count for the unit
timer. On the other hand, if unit timer is not exposed like that, then
perhaps it makes more sense to move latch_mode to counterX/countY, and
introduce latched_time and latched_period under there as well.

William Breathitt Gray
diff mbox series

Patch

diff --git a/Documentation/ABI/testing/sysfs-bus-counter b/Documentation/ABI/testing/sysfs-bus-counter
index 37d960a8cb1b..78bb1a501007 100644
--- a/Documentation/ABI/testing/sysfs-bus-counter
+++ b/Documentation/ABI/testing/sysfs-bus-counter
@@ -59,10 +59,13 @@  What:		/sys/bus/counter/devices/counterX/countY/error_noise_available
 What:		/sys/bus/counter/devices/counterX/countY/function_available
 What:		/sys/bus/counter/devices/counterX/countY/prescaler_available
 What:		/sys/bus/counter/devices/counterX/countY/signalZ_action_available
+What:		/sys/bus/counter/devices/counterX/latch_mode_available
+What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_available
+What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
 KernelVersion:	5.2
 Contact:	linux-iio@vger.kernel.org
 Description:
-		Discrete set of available values for the respective Count Y
+		Discrete set of available values for the respective component
 		configuration are listed in this file. Values are delimited by
 		newline characters.
 
@@ -147,6 +150,14 @@  Description:
 			updates	the respective count. Quadrature encoding
 			determines the direction.
 
+What:		/sys/bus/counter/devices/counterX/countY/latched_count
+KernelVersion:	5.16
+Contact:	linux-iio@vger.kernel.org
+Description:
+		Latched count data of Count Y represented as a string. The value
+		is latched in based on the trigger selected by the
+		counterX/latch_mode attribute.
+
 What:		/sys/bus/counter/devices/counterX/countY/name
 KernelVersion:	5.2
 Contact:	linux-iio@vger.kernel.org
@@ -209,6 +220,7 @@  What:		/sys/bus/counter/devices/counterX/countY/count_mode_component_id
 What:		/sys/bus/counter/devices/counterX/countY/direction_component_id
 What:		/sys/bus/counter/devices/counterX/countY/enable_component_id
 What:		/sys/bus/counter/devices/counterX/countY/error_noise_component_id
+What:		/sys/bus/counter/devices/counterX/countY/latched_count_component_id
 What:		/sys/bus/counter/devices/counterX/countY/prescaler_component_id
 What:		/sys/bus/counter/devices/counterX/countY/preset_component_id
 What:		/sys/bus/counter/devices/counterX/countY/preset_enable_component_id
@@ -218,6 +230,7 @@  What:		/sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
 What:		/sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
 What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
 What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
+What:		/sys/bus/counter/devices/latch_mode_component_id
 What:		/sys/bus/counter/devices/unit_timer_enable_component_id
 What:		/sys/bus/counter/devices/unit_timer_period_component_id
 What:		/sys/bus/counter/devices/unit_timer_time_component_id
@@ -244,6 +257,22 @@  Description:
 		counter_event data structures. The number of elements will be
 		rounded-up to a power of 2.
 
+What:		/sys/bus/counter/devices/counterX/latch_mode
+KernelVersion:	5.16
+Contact:	linux-iio@vger.kernel.org
+Description:
+		Read/write attribute that selects the trigger for latching
+		values. Valid values are device-specific (given by
+		latch_mode_available attribute) and may include:
+
+		"Read count":
+			Reading the countY/count attribute latches values.
+
+		"Unit timeout":
+			Unit timer timeout event latches values.
+
+		The latched values can be read from latched_* attributes.
+
 What:		/sys/bus/counter/devices/counterX/name
 KernelVersion:	5.2
 Contact:	linux-iio@vger.kernel.org
@@ -298,14 +327,6 @@  Description:
 		Active level of index input Signal Y; irrelevant in
 		non-synchronous load mode.
 
-What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_available
-What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
-KernelVersion:	5.2
-Contact:	linux-iio@vger.kernel.org
-Description:
-		Discrete set of available values for the respective Signal Y
-		configuration are listed in this file.
-
 What:		/sys/bus/counter/devices/counterX/signalY/name