diff mbox series

[v4,05/14] iio: document pitch, yaw, roll modifiers

Message ID 20220415130005.85879-6-andrea.merello@gmail.com (mailing list archive)
State Changes Requested
Headers show
Series Add support for Bosch BNO055 IMU | expand

Commit Message

Andrea Merello April 15, 2022, 12:59 p.m. UTC
From: Andrea Merello <andrea.merello@iit.it>

This patch introduces ABI documentation for new modifiers used for
reporting rotations expressed as euler angles (i.e. yaw, pitch, roll).

It looks like we have some unit inconsistency along various IIO modifiers:
it seems that incli is in deg, angl is in radians and rot isn't documented,
but at least the adis16209 driver has rot in deg.

Here we use deg (so angl is the only one using radians).

Signed-off-by: Andrea Merello <andrea.merello@iit.it>
---
 Documentation/ABI/testing/sysfs-bus-iio | 9 +++++++++
 1 file changed, 9 insertions(+)
diff mbox series

Patch

diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
index aadddd43bf22..2a6954ea1c71 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio
+++ b/Documentation/ABI/testing/sysfs-bus-iio
@@ -2039,3 +2039,12 @@  Description:
 		Available range for the forced calibration value, expressed as:
 
 		- a range specified as "[min step max]"
+
+What:		/sys/bus/iio/devices/iio:deviceX/in_rot_yaw_raw
+What:		/sys/bus/iio/devices/iio:deviceX/in_rot_pitch_raw
+What:		/sys/bus/iio/devices/iio:deviceX/in_rot_roll_raw
+KernelVersion:	5.19
+Contact:	linux-iio@vger.kernel.org
+Description:
+		Raw (unscaled) euler angles readings. Units after
+		application of scale are deg.