[v3,01/10] dt-bindings: iio: pressure: honeywell,mprls0025pa.yaml improvements

Message ID 20231229092445.30180-2-petre.rodan@subdimension.ro (mailing list archive)
State Accepted
Headers show
Series changes to mprls0025pa | expand

Commit Message

Petre Rodan Dec. 29, 2023, 9:24 a.m. UTC
Define enum inside the honeywell,transfer-function property block.

Set the correct irq edge in the example block.
Based on the datasheet, in table 13 on page 11:
"End-of-conversion indicator: This pin is set high when a measurement
and calculation have been completed and the data is ready to be
clocked out"

Add description on End-of-conversion interrupt.

Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Co-developed-by: Andreas Klinger <ak@it-klinger.de>
Signed-off-by: Andreas Klinger <ak@it-klinger.de>
Signed-off-by: Petre Rodan <petre.rodan@subdimension.ro>
---
v2 -> v3 no changes

 .../bindings/iio/pressure/honeywell,mprls0025pa.yaml       | 7 ++++++-
 1 file changed, 6 insertions(+), 1 deletion(-)

--
2.41.0
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml
index d9e903fbfd99..84ced4e5a7da 100644
--- a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml
+++ b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml
@@ -42,6 +42,10 @@  properties:
     maxItems: 1

   interrupts:
+    description:
+      Optional interrupt for indicating End-of-conversion.
+      If not present, the driver loops for a while until the received status
+      byte indicates correct measurement.
     maxItems: 1

   reset-gpios:
@@ -65,6 +69,7 @@  properties:
       1 - A, 10% to 90% of 2^24 (1677722 .. 15099494)
       2 - B, 2.5% to 22.5% of 2^24 (419430 .. 3774874)
       3 - C, 20% to 80% of 2^24 (3355443 .. 13421773)
+    enum: [1, 2, 3]
     $ref: /schemas/types.yaml#/definitions/uint32

   vdd-supply:
@@ -93,7 +98,7 @@  examples:
             reg = <0x18>;
             reset-gpios = <&gpio3 19 GPIO_ACTIVE_HIGH>;
             interrupt-parent = <&gpio3>;
-            interrupts = <21 IRQ_TYPE_EDGE_FALLING>;
+            interrupts = <21 IRQ_TYPE_EDGE_RISING>;
             honeywell,pmin-pascal = <0>;
             honeywell,pmax-pascal = <172369>;
             honeywell,transfer-function = <1>;