diff mbox series

[v3,03/10] iio: adc: ad7606: fix wrong scale available

Message ID 20250129-wip-bl-ad7606_add_backend_sw_mode-v3-3-c3aec77c0ab7@baylibre.com (mailing list archive)
State New
Headers show
Series add support for Software mode on AD7606's iio backend driver | expand

Commit Message

Angelo Dureghello Jan. 29, 2025, 11:03 a.m. UTC
From: Angelo Dureghello <adureghello@baylibre.com>

Fix wrong scale available list since only one value is returned:

...
iio:device1: ad7606b (buffer capable)
    8 channels found:
           voltage0:  (input, index: 0, format: le:S16/16>>0)
           2 channel-specific attributes found:
                 attr  0: scale value: 0.305176
                 attr  1: scale_available value: 0.076293
Fix as:
           voltage0:  (input, index: 0, format: le:S16/16>>0)
           2 channel-specific attributes found:
                 attr  0: scale value: 0.305176
                 attr  1: scale_available value: 0.076293 0.152588 0.305176

Fixes: 97c6d857041d ("iio: adc: ad7606: rework scale-available to be static")
Signed-off-by: Angelo Dureghello <adureghello@baylibre.com>
---
 drivers/iio/adc/ad7606.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff mbox series

Patch

diff --git a/drivers/iio/adc/ad7606.c b/drivers/iio/adc/ad7606.c
index d8e3c7a43678..d39354afd539 100644
--- a/drivers/iio/adc/ad7606.c
+++ b/drivers/iio/adc/ad7606.c
@@ -1047,7 +1047,7 @@  static int ad7606_read_avail(struct iio_dev *indio_dev,
 
 		cs = &st->chan_scales[ch];
 		*vals = (int *)cs->scale_avail;
-		*length = cs->num_scales;
+		*length = cs->num_scales * 2;
 		*type = IIO_VAL_INT_PLUS_MICRO;
 
 		return IIO_AVAIL_LIST;