Jonathan Santos Jan. 27, 2025, 3:11 p.m. UTC
From: Sergiu Cuciurean <sergiu.cuciurean@analog.com>

The ad7768-1 ADC output code is two's complement, meaning that the voltage
conversion result is a signed value.. Since the value is a 24 bit one,
stored in a 32 bit variable, the sign should be extended in order to get
the correct representation.

Also the channel description has been updated to signed representation,
to match the ADC specifications.

Fixes: a5f8c7da3dbe ("iio: adc: Add AD7768-1 ADC basic support")
Reviewed-by: David Lechner <dlechner@baylibre.com>
Reviewed-by: Marcelo Schmitt <marcelo.schmitt@analog.com>
Signed-off-by: Sergiu Cuciurean <sergiu.cuciurean@analog.com>
---
v2 Changes:
* Patch moved to the start of the patch series.
---
 drivers/iio/adc/ad7768-1.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)
diff mbox series

Patch

diff --git a/drivers/iio/adc/ad7768-1.c b/drivers/iio/adc/ad7768-1.c
index 113703fb7245..c3cf04311c40 100644
--- a/drivers/iio/adc/ad7768-1.c
+++ b/drivers/iio/adc/ad7768-1.c
@@ -142,7 +142,7 @@  static const struct iio_chan_spec ad7768_channels[] = {
 		.channel = 0,
 		.scan_index = 0,
 		.scan_type = {
-			.sign = 'u',
+			.sign = 's',
 			.realbits = 24,
 			.storagebits = 32,
 			.shift = 8,
@@ -371,7 +371,7 @@  static int ad7768_read_raw(struct iio_dev *indio_dev,
 
 		ret = ad7768_scan_direct(indio_dev);
 		if (ret >= 0)
-			*val = ret;
+			*val = sign_extend32(ret, chan->scan_type.realbits - 1);
 
 		iio_device_release_direct_mode(indio_dev);
 		if (ret < 0)