@@ -706,8 +706,6 @@ static int ina2xx_work_buffer(struct iio_dev *indio_dev)
s64 time;
unsigned int alert;
- time = iio_get_time_ns(indio_dev);
-
/*
* Because the timer thread and the chip conversion clock
* are asynchronous, the period difference will eventually
@@ -736,6 +734,8 @@ static int ina2xx_work_buffer(struct iio_dev *indio_dev)
} while (!alert);
+ time = iio_get_time_ns(indio_dev);
+
/*
* Single register reads: bulk_read will not work with ina226/219
* as there is no auto-increment of the register pointer.
As the timestamp is no longer (ab-)used to measure the function run time, it can be taken at the correct time, i.e. when the conversion has finished. Signed-off-by: Stefan Brüns <stefan.bruens@rwth-aachen.de> --- drivers/iio/adc/ina2xx-adc.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)