@@ -1649,6 +1649,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_raw
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Raw counter device counts from channel Y. For quadrature
counters, multiplication by an available [Y]_scale results in
the counts of a single quadrature signal phase from channel Y.
@@ -1657,6 +1659,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_indexY_raw
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Raw counter device index value from channel Y. This attribute
provides an absolute positional reference (e.g. a pulse once per
revolution) which may be used to home positional systems as
@@ -1666,6 +1670,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_count_count_direction_available
KernelVersion: 4.12
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
A list of possible counting directions which are:
- "up" : counter device is increasing.
- "down": counter device is decreasing.
@@ -1674,4 +1680,6 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_count_direction
KernelVersion: 4.12
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Raw counter device counters direction for channel Y.
@@ -6,6 +6,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_index_synchronous_mode_available
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Discrete set of available values for the respective counter
configuration are listed in this file.
@@ -13,6 +15,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_count_mode
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Count mode for channel Y. Four count modes are available:
normal, range limit, non-recycle, and modulo-n. The preset value
for channel Y is used by the count mode where required.
@@ -47,6 +51,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_noise_error
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Read-only attribute that indicates whether excessive noise is
present at the channel Y count inputs in quadrature clock mode;
irrelevant in non-quadrature clock mode.
@@ -55,6 +61,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_preset
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
If the counter device supports preset registers, the preset
count for channel Y is provided by this attribute.
@@ -62,6 +70,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_quadrature_mode
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Configure channel Y counter for non-quadrature or quadrature
clock mode. Selecting non-quadrature clock mode will disable
synchronous load mode. In quadrature clock mode, the channel Y
@@ -83,6 +93,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_set_to_preset_on_index
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Whether to set channel Y counter with channel Y preset value
when channel Y index input is active, or continuously count.
Valid attribute values are boolean.
@@ -91,6 +103,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_indexY_index_polarity
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Active level of channel Y index input; irrelevant in
non-synchronous load mode.
@@ -98,6 +112,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_indexY_synchronous_mode
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Configure channel Y counter for non-synchronous or synchronous
load mode. Synchronous load mode cannot be selected in
non-quadrature clock mode.