Message ID | 96d81282c95006d857f4d836d2ff3ee0740a85a0.1663025017.git.ang.iglesiasg@gmail.com (mailing list archive) |
---|---|
State | Accepted |
Headers | show |
Series | Add support for pressure sensor Bosch BMP380 | expand |
On Tue, 13 Sep 2022 01:46:42 +0200 Angel Iglesias <ang.iglesiasg@gmail.com> wrote: > On bmp280 and bme280, the temperature and pressure calibration parameters > are available on a contiguous memory region. Considering this arrangement, > simplified the calibration reading function by using only one buffer > to read in batch temperature and pressure registers. > > Signed-off-by: Angel Iglesias <ang.iglesiasg@gmail.com> Applied. Apparently we have a plane, so I'll stop here for now... Jonathan > --- > drivers/iio/pressure/bmp280-core.c | 58 ++++++++++++------------------ > drivers/iio/pressure/bmp280.h | 3 ++ > 2 files changed, 26 insertions(+), 35 deletions(-) > > diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c > index 0ba4ff999f33..4793bcd9f0b3 100644 > --- a/drivers/iio/pressure/bmp280-core.c > +++ b/drivers/iio/pressure/bmp280-core.c > @@ -128,8 +128,7 @@ struct bmp280_chip_info { > * These enums are used for indexing into the array of compensation > * parameters for BMP280. > */ > -enum { T1, T2, T3 }; > -enum { P1, P2, P3, P4, P5, P6, P7, P8, P9 }; > +enum { T1, T2, T3, P1, P2, P3, P4, P5, P6, P7, P8, P9 }; > > static const struct iio_chan_spec bmp280_channels[] = { > { > @@ -153,8 +152,7 @@ static int bmp280_read_calib(struct bmp280_data *data, > struct bmp280_calib *calib, > unsigned int chip) > { > - __le16 p_buf[BMP280_COMP_PRESS_REG_COUNT / 2]; > - __le16 t_buf[BMP280_COMP_TEMP_REG_COUNT / 2]; > + __le16 c_buf[BMP280_CONTIGUOUS_CALIB_REGS / 2]; > struct device *dev = data->dev; > unsigned int tmp; > __le16 l16; > @@ -162,43 +160,33 @@ static int bmp280_read_calib(struct bmp280_data *data, > int ret; > > > - /* Read temperature calibration values. */ > + /* Read temperature and pressure calibration values. */ > ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_TEMP_START, > - t_buf, BMP280_COMP_TEMP_REG_COUNT); > + c_buf, sizeof(c_buf)); > if (ret < 0) { > dev_err(data->dev, > - "failed to read temperature calibration parameters\n"); > + "failed to read temperature and pressure calibration parameters\n"); > return ret; > } > > - /* Toss the temperature calibration data into the entropy pool */ > - add_device_randomness(t_buf, sizeof(t_buf)); > - > - calib->T1 = le16_to_cpu(t_buf[T1]); > - calib->T2 = le16_to_cpu(t_buf[T2]); > - calib->T3 = le16_to_cpu(t_buf[T3]); > - > - /* Read pressure calibration values. */ > - ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_PRESS_START, > - p_buf, BMP280_COMP_PRESS_REG_COUNT); > - if (ret < 0) { > - dev_err(data->dev, > - "failed to read pressure calibration parameters\n"); > - return ret; > - } > - > - /* Toss the pressure calibration data into the entropy pool */ > - add_device_randomness(p_buf, sizeof(p_buf)); > - > - calib->P1 = le16_to_cpu(p_buf[P1]); > - calib->P2 = le16_to_cpu(p_buf[P2]); > - calib->P3 = le16_to_cpu(p_buf[P3]); > - calib->P4 = le16_to_cpu(p_buf[P4]); > - calib->P5 = le16_to_cpu(p_buf[P5]); > - calib->P6 = le16_to_cpu(p_buf[P6]); > - calib->P7 = le16_to_cpu(p_buf[P7]); > - calib->P8 = le16_to_cpu(p_buf[P8]); > - calib->P9 = le16_to_cpu(p_buf[P9]); > + /* Toss the temperature and pressure calibration data into the entropy pool */ > + add_device_randomness(c_buf, sizeof(c_buf)); > + > + /* Parse temperature calibration values. */ > + calib->T1 = le16_to_cpu(c_buf[T1]); > + calib->T2 = le16_to_cpu(c_buf[T2]); > + calib->T3 = le16_to_cpu(c_buf[T3]); > + > + /* Parse pressure calibration values. */ > + calib->P1 = le16_to_cpu(c_buf[P1]); > + calib->P2 = le16_to_cpu(c_buf[P2]); > + calib->P3 = le16_to_cpu(c_buf[P3]); > + calib->P4 = le16_to_cpu(c_buf[P4]); > + calib->P5 = le16_to_cpu(c_buf[P5]); > + calib->P6 = le16_to_cpu(c_buf[P6]); > + calib->P7 = le16_to_cpu(c_buf[P7]); > + calib->P8 = le16_to_cpu(c_buf[P8]); > + calib->P9 = le16_to_cpu(c_buf[P9]); > > /* > * Read humidity calibration values. > diff --git a/drivers/iio/pressure/bmp280.h b/drivers/iio/pressure/bmp280.h > index 4a501836d27a..03a539223417 100644 > --- a/drivers/iio/pressure/bmp280.h > +++ b/drivers/iio/pressure/bmp280.h > @@ -37,6 +37,9 @@ > > #define BMP280_COMP_H5_MASK GENMASK(15, 4) > > +#define BMP280_CONTIGUOUS_CALIB_REGS (BMP280_COMP_TEMP_REG_COUNT + \ > + BMP280_COMP_PRESS_REG_COUNT) > + > #define BMP280_FILTER_MASK GENMASK(4, 2) > #define BMP280_FILTER_OFF 0 > #define BMP280_FILTER_2X 1
diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c index 0ba4ff999f33..4793bcd9f0b3 100644 --- a/drivers/iio/pressure/bmp280-core.c +++ b/drivers/iio/pressure/bmp280-core.c @@ -128,8 +128,7 @@ struct bmp280_chip_info { * These enums are used for indexing into the array of compensation * parameters for BMP280. */ -enum { T1, T2, T3 }; -enum { P1, P2, P3, P4, P5, P6, P7, P8, P9 }; +enum { T1, T2, T3, P1, P2, P3, P4, P5, P6, P7, P8, P9 }; static const struct iio_chan_spec bmp280_channels[] = { { @@ -153,8 +152,7 @@ static int bmp280_read_calib(struct bmp280_data *data, struct bmp280_calib *calib, unsigned int chip) { - __le16 p_buf[BMP280_COMP_PRESS_REG_COUNT / 2]; - __le16 t_buf[BMP280_COMP_TEMP_REG_COUNT / 2]; + __le16 c_buf[BMP280_CONTIGUOUS_CALIB_REGS / 2]; struct device *dev = data->dev; unsigned int tmp; __le16 l16; @@ -162,43 +160,33 @@ static int bmp280_read_calib(struct bmp280_data *data, int ret; - /* Read temperature calibration values. */ + /* Read temperature and pressure calibration values. */ ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_TEMP_START, - t_buf, BMP280_COMP_TEMP_REG_COUNT); + c_buf, sizeof(c_buf)); if (ret < 0) { dev_err(data->dev, - "failed to read temperature calibration parameters\n"); + "failed to read temperature and pressure calibration parameters\n"); return ret; } - /* Toss the temperature calibration data into the entropy pool */ - add_device_randomness(t_buf, sizeof(t_buf)); - - calib->T1 = le16_to_cpu(t_buf[T1]); - calib->T2 = le16_to_cpu(t_buf[T2]); - calib->T3 = le16_to_cpu(t_buf[T3]); - - /* Read pressure calibration values. */ - ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_PRESS_START, - p_buf, BMP280_COMP_PRESS_REG_COUNT); - if (ret < 0) { - dev_err(data->dev, - "failed to read pressure calibration parameters\n"); - return ret; - } - - /* Toss the pressure calibration data into the entropy pool */ - add_device_randomness(p_buf, sizeof(p_buf)); - - calib->P1 = le16_to_cpu(p_buf[P1]); - calib->P2 = le16_to_cpu(p_buf[P2]); - calib->P3 = le16_to_cpu(p_buf[P3]); - calib->P4 = le16_to_cpu(p_buf[P4]); - calib->P5 = le16_to_cpu(p_buf[P5]); - calib->P6 = le16_to_cpu(p_buf[P6]); - calib->P7 = le16_to_cpu(p_buf[P7]); - calib->P8 = le16_to_cpu(p_buf[P8]); - calib->P9 = le16_to_cpu(p_buf[P9]); + /* Toss the temperature and pressure calibration data into the entropy pool */ + add_device_randomness(c_buf, sizeof(c_buf)); + + /* Parse temperature calibration values. */ + calib->T1 = le16_to_cpu(c_buf[T1]); + calib->T2 = le16_to_cpu(c_buf[T2]); + calib->T3 = le16_to_cpu(c_buf[T3]); + + /* Parse pressure calibration values. */ + calib->P1 = le16_to_cpu(c_buf[P1]); + calib->P2 = le16_to_cpu(c_buf[P2]); + calib->P3 = le16_to_cpu(c_buf[P3]); + calib->P4 = le16_to_cpu(c_buf[P4]); + calib->P5 = le16_to_cpu(c_buf[P5]); + calib->P6 = le16_to_cpu(c_buf[P6]); + calib->P7 = le16_to_cpu(c_buf[P7]); + calib->P8 = le16_to_cpu(c_buf[P8]); + calib->P9 = le16_to_cpu(c_buf[P9]); /* * Read humidity calibration values. diff --git a/drivers/iio/pressure/bmp280.h b/drivers/iio/pressure/bmp280.h index 4a501836d27a..03a539223417 100644 --- a/drivers/iio/pressure/bmp280.h +++ b/drivers/iio/pressure/bmp280.h @@ -37,6 +37,9 @@ #define BMP280_COMP_H5_MASK GENMASK(15, 4) +#define BMP280_CONTIGUOUS_CALIB_REGS (BMP280_COMP_TEMP_REG_COUNT + \ + BMP280_COMP_PRESS_REG_COUNT) + #define BMP280_FILTER_MASK GENMASK(4, 2) #define BMP280_FILTER_OFF 0 #define BMP280_FILTER_2X 1
On bmp280 and bme280, the temperature and pressure calibration parameters are available on a contiguous memory region. Considering this arrangement, simplified the calibration reading function by using only one buffer to read in batch temperature and pressure registers. Signed-off-by: Angel Iglesias <ang.iglesiasg@gmail.com> --- drivers/iio/pressure/bmp280-core.c | 58 ++++++++++++------------------ drivers/iio/pressure/bmp280.h | 3 ++ 2 files changed, 26 insertions(+), 35 deletions(-)