diff mbox

[PATCHv3,1/4] mfd: da9052: fix manual ADC read after timed out read

Message ID 20170629124346.22325-2-sebastian.reichel@collabora.co.uk (mailing list archive)
State New, archived
Headers show

Commit Message

Sebastian Reichel June 29, 2017, 12:43 p.m. UTC
It is possible that under heavy system load, the counter in the completion
struct, used for waiting for end of AD conversion, gets incremented twice.
To make sure the driver recovers from this situation, the completion struct
should be reinitialized.

Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
---
 drivers/mfd/da9052-core.c | 2 ++
 1 file changed, 2 insertions(+)
diff mbox

Patch

diff --git a/drivers/mfd/da9052-core.c b/drivers/mfd/da9052-core.c
index a88c2065d8ab..977418ca9117 100644
--- a/drivers/mfd/da9052-core.c
+++ b/drivers/mfd/da9052-core.c
@@ -386,6 +386,8 @@  int da9052_adc_manual_read(struct da9052 *da9052, unsigned char channel)
 
 	mutex_lock(&da9052->auxadc_lock);
 
+	reinit_completion(&da9052->done);
+
 	/* Channel gets activated on enabling the Conversion bit */
 	mux_sel = chan_mux[channel] | DA9052_ADC_MAN_MAN_CONV;