Device tree binding information for DA9062 and DA9061 thermal junction
temperature monitor.

Binding descriptions for the DA9061 and DA9062 thermal TJUNC supervisor
device driver, using a single THERMAL_TRIP_HOT trip-wire and allowing for
a configurable polling period for over-temperature polling.

This patch also adds two examples, one for DA9062 and one for DA9061. The 
DA9061 example uses a fall-back compatible string for the DA9062.

Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Steve Twiss <stwiss.opensource@diasemi.com>

---
This patch applies against linux-next and v4.8

v3 -> v4
 - NO CODE CHANGE
 - Patch renamed from [PATCH V3 3/9] to [PATCH V4 2/8]
 - Added Acked-by Rob Herring

v2 -> v3
 - Patch renamed from [PATCH V2 03/10] to [PATCH V3 3/9]
 - Changes suggested from other component reviews by Rob Herring:
 - Each compatible line should be a valid combination of compatible
   strings: alter DA9061 line to include the fall back compatible string
   and update the commit message accordingly
 - Add e-mail information about associated patches from this set without
   describing them as being explicitly dependent on this binding

v1 -> v2
 - Patch renamed from [PATCH V1 08/10] to [PATCH V2 03/10] -- these
   changes were made to fix checkpatch warnings caused by the patch
   set dependency order
 - A second example for DA9061 is provided to highlight the use of a
   fall-back compatible option for the DA9062

Hi,

No code changes for this version PATCH V4. Added an Ack by Rob Herring
for PATCH V3.

As previously:
The device driver from this patch set (associated with this binding) is:
  [PATCH V4 7/8] thermal: da9061: TJUNC temperature driver 

Regards,
Steve Twiss, Dialog Semiconductor Ltd.


 .../devicetree/bindings/thermal/da9062-thermal.txt | 37 ++++++++++++++++++++++
 1 file changed, 37 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/thermal/da9062-thermal.txt
diff mbox

Patch

diff --git a/Documentation/devicetree/bindings/thermal/da9062-thermal.txt b/Documentation/devicetree/bindings/thermal/da9062-thermal.txt
new file mode 100644
index 0000000..460ce68
--- /dev/null
+++ b/Documentation/devicetree/bindings/thermal/da9062-thermal.txt
@@ -0,0 +1,37 @@ 
+* Dialog DA9062/61 TJUNC Thermal Module
+
+This module is part of the DA9061/DA9062. For more details about entire
+DA9062 and DA9061 chips see Documentation/devicetree/bindings/mfd/da9062.txt
+
+Junction temperature thermal module uses an interrupt signal to identify
+high THERMAL_TRIP_HOT temperatures for the PMIC device.
+
+Required properties:
+
+- compatible: should be one of the following valid compatible string lines:
+        "dlg,da9061-thermal", "dlg,da9062-thermal"
+        "dlg,da9062-thermal"
+
+Optional properties:
+
+- dlg,tjunc-temp-polling-period-ms : Specify the polling period, measured
+    in milliseconds, between thermal zone device update checks.
+
+Example: DA9062
+
+	pmic0: da9062@58 {
+		thermal {
+			compatible = "dlg,da9062-thermal";
+			dlg,tjunc-temp-polling-period-ms = <3000>;
+		};
+	};
+
+Example: DA9061 using a fall-back compatible for the DA9062 onkey driver
+
+	pmic0: da9061@58 {
+		thermal {
+			compatible = "dlg,da9061-thermal", "dlg,da9062-thermal";
+			dlg,tjunc-temp-polling-period-ms = <3000>;
+		};
+	};
+